Dosimetric Comparison of Volumetric Modulated Arc Therapy, Step-And-Shoot, and Sliding Window IMRT for Prostate Cancer

被引:0
|
作者
Schnell, Erich [1 ]
Herman, Tania De La Fuente [1 ]
Young, Julie [1 ]
Hildebrand, Kim [1 ]
Algan, Ozer [1 ]
Syzek, Elizabeth [1 ]
Herman, Terence [1 ]
Ahmad, Salahuddin [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dept Radiat Oncol, Oklahoma City, OK 73104 USA
来源
MEDICAL PHYSICS | 2012年 / 1494卷
关键词
Prostate Cancer; Intensity Modulated Radiation Therapy; Volumetric Modulated Arc Therapy; Step and Shoot; Sliding Window; COMPLICATION PROBABILITY; BRACHYTHERAPY; IRRADIATION;
D O I
10.1063/1.4764589
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to evaluate treatment plans generated by Step-and-Shoot (SS), Sliding Window (SW) and Volumetric Modulated Arc Therapy (VMAT) in order to assess the differences in dose volume histograms of planning target volume (PTV) and organs at risk (OAR), conformity indices, radiobiological evaluations, and plan quality for prostate cancer cases. Six prostate cancer patients treated in our center were selected for this retrospective study. Treatment plans were generated with Eclipse version 8.9 using 10 MV photon beams. For VMAT, Varian Rapid Arc with 1 or 2 arcs, and for SS and SW IMRT, 7-9 fields were used. Each plan had three PTVs with prescription doses of 81, 59.4, and 45 Gy to prostate, to prostate and lymph nodes, and to pelvis, respectively. Doses to PTV and OAR and the conformal indices (COIN) were compared among three techniques. The equivalent uniform dose (EUD), tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated and compared. The mean doses to the PTV prostate on average were 83 Gy and the percent differences of mean dose among all techniques were below 0.28. For bladder and rectum, the percent differences of mean dose among all techniques were below 2.2. The COIN did not favour any particular delivery method over the other. The TCP was higher with SS and SW for four patients and higher with VMAT for two patients. The NTCP for the rectum was the lowest with VMAT in five out of the six patients. The results show similar target coverage in general.
引用
收藏
页码:23 / 26
页数:4
相关论文
共 50 条
  • [31] Assessing the Dosimetric Impact of Intra-Fraction Prostate Motion On Step-And-Shoot IMRT Plans
    Langen, K.
    Moore, J.
    Kupelian, P.
    Siebers, J.
    MEDICAL PHYSICS, 2009, 36 (06) : 2550 - +
  • [32] Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer
    Li, Zhiping
    Zeng, Jianshuang
    Wang, Zi
    Zhu, Hong
    Wei, Yuquan
    ONCOLOGY LETTERS, 2014, 8 (04) : 1427 - 1434
  • [33] Analysis of the Dosimetric Effect of Intrafraction Motion on Step-and-shoot IMRT Plans
    Waghorn, B. J.
    Chauhan, B. D.
    Rineer, J. M.
    Meeks, S. L.
    Langen, K. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S847 - S848
  • [34] Dosimetric evaluation of IMRT Step and Shoot/ Sliding and Window (SS / SW) and VMAT Treatment Plans for Nasopharyngeal Cancer
    Errifai, Rachid
    Bouzekraoui, Youssef
    Bentayeb, Farida
    Iranian Journal of Medical Physics, 2022, 19 (01) : 31 - 42
  • [35] Volumetric modulated arc therapy (VMAT) for semi-complex target volumes - a comparison with step-and -shoot IMRT in prostate carcinoma with simultaneous integrated boost
    Guckenberger, A.
    Richter, A.
    Krieger, T.
    Baier, K.
    Wilbert, J.
    Flentje, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 41 - 41
  • [36] Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy
    Wiersma, R. D.
    Xing, L.
    MEDICAL PHYSICS, 2007, 34 (10) : 3962 - 3970
  • [37] Dosimetric effects of jaw tracking in step-and-shoot intensity-modulated radiation therapy
    Joy, Sarah
    Starkschall, George
    Kry, Stephen
    Salehpour, Mohammed
    White, R. Allen
    Lin, Steven H.
    Balter, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (02): : 136 - 145
  • [38] Temporal, dosimetric, and geometric precision of gated step-and-shoot intensity modulated radiation therapy
    Wiersma, R. D.
    Xing, L.
    MEDICAL PHYSICS, 2007, 34 (06) : 2601 - 2601
  • [39] Volumetric modulated arc therapy for prostate cancer
    Afghan, M. K. N.
    Cao, D.
    Mehta, V.
    Wong, T.
    Ye, J.
    Shepard, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S665 - S666
  • [40] A Dosimetric Comparison of Volumetric-modulated Arc Therapy and IMRT for Cochlea-sparing Radiation Therapy in Locally Advanced Nasopharyngeal Cancer
    Nanda, Siddhartha
    Parida, Sourajit
    Ahirwar, Manish Kumar
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 248 - 251