Dosimetric effects of intrafractional isocenter variation during deep inspiration breath-hold for breast cancer patients using surface-guided radiotherapy

被引:43
|
作者
Kugele, Malin [1 ,2 ]
Edvardsson, Anneli [2 ]
Berg, Lovisa [1 ]
Alkner, Sara [1 ]
Ljus, Carina Andersson [1 ]
Ceberg, Sofie [1 ,2 ]
机构
[1] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Lund, Sweden
[2] Lund Univ, Dept Clin Sci, Med Radiat Phys, Lund, Sweden
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2018年 / 19卷 / 01期
关键词
breath hold; intrafractional isocenter variation; optical surface scanning; treatment planning; RADIATION-THERAPY; HEART-DISEASE; RISK; WOMEN; REPRODUCIBILITY; MORTALITY; COHORT;
D O I
10.1002/acm2.12214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to investigate potential dose reductions to the heart, left anterior descending coronary artery (LAD), and ipsilateral lung for left-sided breast cancer using visually guided deep inspiration breath-hold (DIBH) with the optical surface scanning system Catalyst (TM), and how these potential dosimetric benefits are affected by intrafractional motion in between breath holds. For both DIBH and free breathing (FB), treatment plans were created for 20 tangential and 20 locoregional left-sided breast cancer patients. During DIBH treatment, beam-on was triggered by a region of interest on the xiphoid process using a 3 mm gating window. Using a novel nonrigid algorithm, the Catalyst (TM) system allows for simultaneous real-time tracking of the isocenter position, which was used to calculate the intrafractional DIBH isocenter reproducibility. The 50% and 90% cumulative probabilities and maximum values of the intrafractional DIBH isocenter reproducibility were calculated and to obtain the dosimetric effect isocenter shifts corresponding to these values were performed in the treatment planning system. For both tangential and locoregional treatment, the dose to the heart, LAD and ipsilateral lung was significantly reduced for DIBH compared to FB. The intrafractional DIBH isocenter reproducibility was very good for the majority of the treatment sessions, with median values of approximately 1 mm in all three translational directions. However, for a few treatment sessions, intrafractional DIBH isocenter reproducibility of up to 5 mm was observed, which resulted in large dosimetric effects on the target volume and organs at risk. Hence, it is of importance to set tolerance levels on the intrafractional isocenter motion and not only perform DIBH based on the xiphoid process.
引用
收藏
页码:25 / 38
页数:14
相关论文
共 50 条
  • [21] Dosimetric comparison of free-breathing and deep inspiration breath-hold radiotherapy for lung cancer
    Marchand, V.
    Zefkili, S.
    Desrousseaux, J.
    Simon, L.
    Dauphinot, C.
    Giraud, P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (07) : 582 - 589
  • [22] Failure mode and effects analysis in consensus-based GDM for surface-guided deep inspiration breath-hold breast radiotherapy for breast cancer under the framework of linguistic Z-number
    Mandal, Prasenjit
    Samanta, Sovan
    Pal, Madhumangal
    INFORMATION SCIENCES, 2024, 658
  • [23] Dosimetric Effects of Intrafractional Target Motion Using the Xiphiod Process as a Surrogate During Deep Inspiration Breath Hold for Left-Sided Breast Cancer
    Kugele, M. L.
    Edvardsson, A.
    Ceberg, S.
    Berg, L.
    Andersson-Ljus, C.
    Alkner, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E680 - E680
  • [24] Setup margins based on the inter- and intrafractional setup error of left-sided breast cancer radiotherapy using deep inspiration breath-hold technique (DIBH) and surface guided radiotherapy (SGRT)
    Rudat, Volker
    Shi, Yanyan
    Zhao, Ruping
    Yu, Wei
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (06):
  • [25] Intrafractional fiducial marker position variations in stereotactic liver radiotherapy during voluntary deep inspiration breath-hold
    Stick, Line Bjerregaard
    Vogelius, Ivan Richter
    Risum, Signe
    Josipovic, Mirjana
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1116):
  • [26] Cardiac Movement in Deep Inspiration Breath-Hold for Left-Breast Cancer Radiotherapy
    Kim, M.
    Lee, S.
    Suh, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 162 - 162
  • [27] Gated Radiotherapy with deep inspiration breath-hold in left-sided breast cancer
    Micke, O.
    Kisters, K.
    Schaefer, U.
    Muecke, R.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S910 - S910
  • [28] Deep inspiration breath-hold (DIBH) radiotherapy in left-sided breast cancer
    Hepp, Rodrigo
    Ammerpohl, Mark
    Morgenstern, Christina
    Nielinger, Lisa
    Erichsen, Patricia
    Abdallah, Abdallah
    Galalae, Razvan
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (09) : 710 - 716
  • [29] Reproducibility of deep inspiration breath-hold and dosimetric implications in treatments of left-breast cancer
    Porcu, P.
    Fassi, A.
    Tabarelli, P.
    Liotta, M.
    Meaglia, I.
    Bocci, C.
    Riboldi, M.
    Baroni, G.
    Ivaldi, G. B.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S187 - S187
  • [30] Deep Inspiration Breath-Hold (DIBH) Radiotherapy in Left-Sided Breast Cancer Patients After Mastectomy: A Dosimetric Comparison Study
    Zhao, F.
    Yao, G.
    Shen, J.
    Luo, Y.
    Bu, L.
    Zhu, Q.
    Lu, Z.
    Yan, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E319 - E319