Delivery of erythropoietin with a needleless injection system during hemodialysis maintains plasma levels

被引:0
|
作者
Petersen, J [1 ]
Jani, A [1 ]
机构
[1] Stanford Univ, Med Ctr, Div Nephrol, Stanford, CA 94305 USA
关键词
D O I
10.1097/00002480-200111000-00007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent Occupational Safety and Health Administration guidelines require the implementation of needleless systems in dialysis units in the state of California. It is not known whether needleless systems deliver medication as well as traditional low dead-space needle/syringes. The purpose of this study was to compare the delivery of recombinant human erythropoietin (rHuEpo) by a needleless system (Medic Plastic Anti-Stick Needle/Connector, Medisystems, Seattle, WA) with delivery using a traditional low dead-space needle/syringe. We also studied the Medisystems High Flow venous chamber with integral injection site that is designed to prevent the formation of a separate serum layer within which rHuEpo may become trapped. There was no significant difference in the mean serum rHuEpo concentration achieved by either the needleless system, or traditional low dead-space needle/syringe, whether using the venous chamber's integral injection site or the postvenous chamber in-line injection site. This study demonstrates for the first time that a needleless system of delivery can reliably achieve serum rHuEpo comparable to traditional low dead-space needle/syringes.
引用
收藏
页码:608 / 610
页数:3
相关论文
共 50 条
  • [31] STABLE DELIVERY OF PHYSIOLOGICAL LEVELS OF RECOMBINANT ERYTHROPOIETIN TO THE SYSTEMIC CIRCULATION BY INTRAMUSCULAR INJECTION OF REPLICATION-DEFECTIVE ADENOVIRUS
    BARR, E
    TRIPATHY, SK
    GOLDWASSER, E
    LEIDEN, JM
    CIRCULATION, 1994, 90 (04) : 3 - 3
  • [32] PLASMA-LEVELS OF BETA-ENDORPHIN IN UREMIC PATIENTS DURING HEMODIALYSIS
    CARUSO, U
    LEZOCHE, E
    MARIANI, P
    ELLI, M
    TISONE, G
    CRAVOTTO, E
    CASCIANI, CU
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY RESEARCH, 1988, 8 (01) : 17 - 20
  • [33] PLASMA-LEVELS OF MAIN GRANULOCYTE COMPONENTS DURING HEMODIALYSIS - EFFECTS OF IMMUNOSUPPRESSION
    RIEGEL, W
    LEVERENZ, K
    SCHOLLMEYER, P
    WILMS, H
    HORL, WH
    NEPHRON, 1987, 46 (02): : 161 - 166
  • [34] PLASMA-LEVELS OF TUMOR-NECROSIS-FACTOR-ALPHA DURING HEMODIALYSIS
    PAYDAS, S
    AKSU, HSZ
    PAYDAS, S
    KARADEMIR, M
    GURCAY, AA
    NEPHRON, 1991, 57 (04): : 477 - 478
  • [35] PLASMA LRH LEVELS IN CHRONIC-RENAL-FAILURE BEFORE AND DURING HEMODIALYSIS
    MATSUBARA, M
    NAKAGAWA, K
    NONOMURA, K
    HIROTA, N
    ACTA ENDOCRINOLOGICA, 1983, 103 (02): : 145 - 150
  • [36] CHANGES IN PLASMA-LEVELS OF VASOACTIVE PEPTIDES DURING STANDARD BICARBONATE HEMODIALYSIS
    HEGBRANT, J
    THYSELL, H
    MARTENSSON, L
    EKMAN, R
    BOBERG, U
    NEPHRON, 1993, 63 (03) : 303 - 308
  • [37] CHANGES IN PLASMA-LEVELS OF VASOACTIVE PEPTIDES DURING SEQUENTIAL BICARBONATE HEMODIALYSIS
    HEGBRANT, J
    THYSELL, H
    MARTENSSON, L
    EKMAN, R
    BOBERG, U
    NEPHRON, 1993, 63 (03) : 309 - 313
  • [38] INCREASED INTRACRANIAL PRESSURE FROM UNSUSTAINED LEVELS OF PLASMA MANNITOL DURING HEMODIALYSIS
    RANDALL, RE
    SINGH, R
    LASTER, J
    BELLE, C
    SETTER, JG
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1967, 70 (01): : 129 - &
  • [39] Short-term erythropoietin therapy does not increase plasma tissue factor and its inhibitor levels in hemodialysis patients
    Borawski, J
    Naumnik, B
    Mysliwiec, M
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2003, 9 (02) : 173 - 174
  • [40] The study of maternal and fetal plasma catecholamines levels during pregnancy and delivery
    Wang, L
    Zhang, WY
    Zhao, YH
    JOURNAL OF PERINATAL MEDICINE, 1999, 27 (03) : 195 - 198