Methodologies for the airbrush application of MALDI matrices

被引:7
|
作者
Warren, Alexander D. [1 ]
Mitchell, David J. [2 ]
Gates, Paul J. [1 ]
机构
[1] Univ Bristol, Sch Chem, Cantocks Close, Bristol BS8 1TS, Avon, England
[2] AWE, Directorate Sci & Technol, Reading, Berks, England
基金
英国工程与自然科学研究理事会;
关键词
Matrix-assisted laser desorption; matrix; airbrush; colloidal graphite; traditional matrices; ASSISTED LASER DESORPTION/IONISATION; IMAGING MASS-SPECTROMETRY; COLLOIDAL GRAPHITE; SMALL MOLECULES; METABOLITES; SECTIONS; PENCIL; TISSUE; MSN;
D O I
10.1177/1469066717750031
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
There is still a need to develop reliable and robust matrix deposition methods for matrix-assisted laser desorption/ionisation mass spectrometry that are applicable to a range of matrices, solvents and analyte types. This paper presents a robust methodology for the airbrush application of matrices along with the implications of varying the set-up and airbrush parameters. A small number of organic analytes and metal salts are analysed in both positive and negative ion modes to exemplify this methodology. In the analyses with the airbrush deposited matrices, performance was enhanced when compared to standard pipette deposition with the need for a search for sweat spots greatly diminished due to the increase homogeneity of the matrix surface and resultant analyte spots. As expected, the graphite matrices were shown to specifically outperform the organic matrices in negative ion mode.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [41] Evolving methodologies: From creation to application
    Berkson, J
    Kline, LL
    Orth, DJ
    INCORPORATING UNCERTAINTY INTO FISHERY MODELS, 2002, 27 : 1 - 8
  • [42] APPLICATION OF ACTIVE METHODOLOGIES IN A UNIVERSITY SUBJECT
    Oltra-Badenes, Raul
    13TH INTERNATIONAL TECHNOLOGY, EDUCATION AND DEVELOPMENT CONFERENCE (INTED2019), 2019, : 2767 - 2771
  • [43] Global optimization methodologies and application in electromechanics
    Di Barba, Paolo
    Savini, Antonio
    International journal of applied electromagnetics in materials, 1993, 4 (02): : 93 - 98
  • [44] Application of Robust Parameter Design Methodologies
    M. B. Moghadam
    Quality and Quantity, 2005, 39 : 175 - 188
  • [45] Application of docking methodologies to modeled proteins
    Singh, Amar
    Dauzhenka, Taras
    Kundrotas, Petras J.
    Sternberg, Michael J. E.
    Vakser, Ilya A.
    PROTEINS-STRUCTURE FUNCTION AND BIOINFORMATICS, 2020, 88 (09) : 1180 - 1188
  • [46] COMPARISON OF MOBILE APPLICATION DEVELOPMENT METHODOLOGIES
    Molina Rios, Jimmy Rolando
    Honores Tapia, Joofre Antonio
    Pedreira-Souto, Nieves
    Pardo Leon, Henry Paul
    3C TECNOLOGIA, 2021, 10 (02): : 73 - 93
  • [47] Strategies for Web Application Development Methodologies
    Sharma, Ravi
    Kumar, Shipra Ravi
    Gupta, Keshav
    2016 IEEE INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION AND AUTOMATION (ICCCA), 2016, : 160 - 165
  • [48] A neurocomputing framework: From methodologies to application
    Cho, SB
    NEUROCOMPUTING, 1996, 13 (2-4) : 151 - 170
  • [49] Application of robust parameter design methodologies
    Moghadam, MB
    QUALITY & QUANTITY, 2005, 39 (02) : 175 - 188
  • [50] Data combination from multiple matrix-assisted laser desorption/ionization (MALDI) matrices: opportunities and limitations for MALDI analysis
    Kouvonen, Petri
    Rainio, Eeva M.
    Suni, Veronika
    Koskinen, Paivi
    Corthals, Garry L.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (23) : 3493 - 3495