Collector cable design based on dynamic line rating for wind energy applications

被引:2
|
作者
Wijethunga, A. H. [1 ,2 ]
Ekanayake, J. B. [2 ]
Wijayakulasooriya, J. V. [2 ]
机构
[1] Sri Lanka Technol Campus, Padukka, Sri Lanka
[2] Univ Peradeniya, Dept Elect & Elect Engn, Fac Engn, Peradeniya, Sri Lanka
基金
美国国家科学基金会;
关键词
Collector network; dynamic line rating; wind power;
D O I
10.4038/jnsfsr.v46i1.8263
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Wind power will play a major role in future power generation systems. In order to promote more and more wind farm connections, the capital cost (CAPEX) should be minimised In this paper a novel concept is presented based on two practical considerations, namely, the actual current through different sections of a radially connected wind turbine string reduces from the substation end to the farthest wind turbine; and the current carrying capacity of a conductor and wind turbine current increases with the wind speed. Two tools that support the design of the collector network and ensure safe operation of the overhead collector conductors were developed. The first tool aids the designing of the collector conductors based on the dynamic line rating of the conductor and the actual wind farm output at different wind speeds. The second tool is a verification tool, which ensures that the conductor core temperature does not exceed the maximum allowable conductor temperature. A case study is presented to demonstrate the use of the design tool whereas a real life implementation is used to demonstrate that the verification tool can be used in a real wind farm to ensure the safety of the conductors.
引用
收藏
页码:31 / 40
页数:10
相关论文
共 50 条
  • [1] Dynamic line rating for wind power
    Talpur, Saifal
    Wallnerstrom, Carl Johan
    Flood, Christer
    Hilber, Patrik
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2016, 8 (01)
  • [2] PMU-Based Cable Temperature Monitoring and Thermal Assessment for Dynamic Line Rating
    Singh, Ravi Shankar
    Cobben, Sjef
    Cuk, Vladimir
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (03) : 1859 - 1868
  • [3] Performance of Dynamic Line Rating Systems for Wind Integration
    Olazarri, J. G.
    Mazon, A. J.
    Rementeria, S.
    Albizu, I.
    Fernandez, E.
    2015 INTERNATIONAL CONFERENCE ON CLEAN ELECTRICAL POWER (ICCEP), 2015, : 567 - 573
  • [4] Dynamic line rating systems for wind power integration
    Fernandez, E.
    Albizu, I.
    Bedialauneta, M. T.
    Mazon, A. J.
    Leite, P. T.
    2012 IEEE POWER ENGINEERING SOCIETY CONFERENCE AND EXPOSITION IN AFRICA (POWERAFRICA), 2012,
  • [5] Dynamic Line Rating Protection for Wind Farm Connections
    Yip, Tony
    An, Chang
    Lloyd, Graeme
    Aten, Martin
    Ferris, Bob
    2009 CIGRE/IEEE PES JOINT SYMPOSIUM INTEGRATION OF WIDE-SCALE RENEWABLE RESOURCES INTO THE POWER DELIVERY SYSTEM, 2009, : 330 - 334
  • [6] Influence of the wind variability on the calculation of dynamic line rating
    Gonzalez-Cagigal, M. a.
    Rosendo-Macias, J. A.
    Bachiller-Soler, A.
    Senas-Sanvicente, D.
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 211
  • [7] Optimizing the Cable Designs for Wind Energy Applications
    Wickramagedara, M. W. B. K.
    Ekanayake, J. B.
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON SMART TECHNOLOGIES FOR SMART NATION (SMARTTECHCON), 2017, : 1524 - 1525
  • [8] Minimization of Wind Power Curtailment using Dynamic Line Rating
    Manakari, Vageesh Chakrapani
    Thengius, Sandra
    Ravi, Akshaya Tammanur
    Morozovska, Kateryna
    Hilber, Patrik
    2020 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE 2020): SMART GRIDS: KEY ENABLERS OF A GREEN POWER SYSTEM, 2020, : 615 - 619
  • [9] Impact From Dynamic Line Rating on Wind Power Integration
    Wallnerstrom, Carl Johan
    Huang, Yalin
    Soder, Lennart
    IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (01) : 343 - 350
  • [10] Dynamic Line Rating of Wind Farm Integration Transmission Lines
    Chen Xiong
    Luo Jianbo
    2017 IEEE 7TH ANNUAL INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2017, : 1291 - 1295