Frequency-Offset Method to Determine Conversion Coefficient of Extremely Low-Frequency Magnetic Field Detector

被引:0
|
作者
Hwang, Jung-Hwan [1 ]
Kwon, Jong-Hwa [1 ]
Choi, Hyung-Do [1 ]
机构
[1] Elect & Telecommun Res Inst, Radio Environm & Monitoring Res Grp, Daejeon, South Korea
关键词
Magnetic fields; electromagnetic measurements; magnetic field strength; DATA-ACQUISITION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a frequency-offset method to determine a conversion coefficient of an extremely low-frequency magnetic field (ELF-MF) detector to measure the strength of a power-line magnetic field, which is caused by electricity operating at 60 or 50 Hz. Using the frequency-offset method, the conversion coefficient can be determined in spite of interference caused by ambient noise. The frequency-offset method in this paper can be effectively used to develop an ELF-MF detector in a ambient noise environment.
引用
收藏
页码:5 / 10
页数:6
相关论文
共 50 条
  • [41] Effects of Extremely Low-Frequency Magnetic Field on Growth and Differentiation of Human Mesenchymal Stem Cells
    Yan, Jihong
    Dong, Liang
    Zhang, Baohong
    Qi, Nianmin
    ELECTROMAGNETIC BIOLOGY AND MEDICINE, 2010, 29 (04) : 165 - 176
  • [42] Range Detection of the Extremely Low-Frequency Magnetic Field Produced by Laptop's AC Adapter
    Brodic, Darko
    Amelio, Alessia
    MEASUREMENT SCIENCE REVIEW, 2017, 17 (01): : 1 - 8
  • [43] EFFECT OF EXTREMELY LOW-FREQUENCY MAGNETIC-FIELD ON SERUM-CHOLINESTERASE IN HUMANS AND ANIMALS
    RAJESWARI, KR
    SATYANARAYANA, M
    NARAYAN, PVS
    SUBRAHMANYAM, S
    INDIAN JOURNAL OF EXPERIMENTAL BIOLOGY, 1985, 23 (04) : 194 - 197
  • [44] COMPARATIVE ANALYSIS OF THE EXTREMELY LOW-FREQUENCY MAGNETIC FIELD EXPOSURE FROM OVERHEAD POWER LINES
    Lunca, Eduard
    Istrate, Marcel
    Salceanu, Alexandru
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2013, 12 (06): : 1145 - 1151
  • [45] Low-complexity coarse frequency-offset synchronization for OFDM applications
    You, YH
    Paik, JH
    Park, CH
    Ju, MC
    Kwon, KW
    Cho, JW
    2001 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS, VOLS 1-10, CONFERENCE RECORD, 2001, : 2494 - 2498
  • [46] Ultra-low-power FSK demodulator with frequency-offset tolerance
    Yin, Yadong
    Zhang, Lihong
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 14 (05) : 768 - 772
  • [47] Low-complexity frequency-offset insensitive detection for orthogonal modulation
    Park, S
    Park, D
    Park, H
    Lee, K
    ELECTRONICS LETTERS, 2005, 41 (22) : 1226 - 1228
  • [48] ON THE LOW-FIELD, LOW-FREQUENCY SUSCEPTIBILITY OF MAGNETIC FLUIDS
    SCAIFE, BKP
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1986, 19 (10) : L195 - L197
  • [49] Survey of public exposure to extremely low-frequency magnetic fields in the dwellings
    Ghanbari, Ghazal
    Khodakarim, Soheila
    Eslami, Akbar
    ENVIRONMENTAL HEALTH ENGINEERING AND MANAGEMENT JOURNAL, 2022, 9 (01): : 1 - 7
  • [50] Impact of extremely low-frequency magnetic fields on human postural control
    Villard, Sebastien
    Allen, Alicia
    Bouisset, Nicolas
    Corbacio, Michael
    Thomas, Alex
    Guerraz, Michel
    Legros, Alexandre
    EXPERIMENTAL BRAIN RESEARCH, 2019, 237 (03) : 611 - 623