Bienzymatic Acetylcholinesterase and Choline Oxidase Immobilized Biosensor Based on a Phenyl Carboxylic Acid-Grafted Multiwalled Carbon Nanotube

被引:6
|
作者
Lee, So-Ra [1 ]
Lee, Hyo-Eun [1 ]
Kang, Yun Ok [1 ]
Hwang, Wan-Seok [2 ]
Choi, Seong-Ho [1 ]
机构
[1] Hannam Univ, Dept Chem, Taejon 305811, South Korea
[2] RedoxTech, Seoul 131823, South Korea
基金
新加坡国家研究基金会;
关键词
SENSING PHENOLICS; ELECTRODE; NANOPARTICLES;
D O I
10.1155/2014/971942
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Bienzymatic acetylcholinesterase (AChE) and choline oxidase (ChOx) immobilized biosensor based on a phenyl carboxylic acid-grafted multiwalled carbon nanotube (MWNT) modified glass carbon electrode (GCE) and carbon-screen printed electrode (SPE) was fabricated for acetylcholine detection in human blood samples. Phenyl carboxylic acid-modified MWNT supports were prepared by electrochemical polymerization of 4-carboxyphenyl diazonium salts, which were synthesized by an amine group and sodium nitrite, on the surface of the MWNT-modified GCE and SPE in 0.1 M PBS. The successful fabrication of the AChE-ChOx-immobilized biosensor was confirmed via scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The sensing range of the biosensor based on a GCE and SPE was 1.0 similar to 10 mu M and 10 similar to 100 mu M, respectively. The interfering effect of 0.1 M L-ascorbic acid, 0.1 M L-cysteine, and 0.1 M-uric acid to 0.1 M acetylcholine was 3.00%, 9.00%, and 3.00%, respectively. Acetylcholine in a human blood sample was detected by the AChE-ChOx-immobilized biosensor.
引用
收藏
页数:12
相关论文
共 28 条
  • [21] An electrochemical biosensor based on multi-wall carbon nanotube-modified screen-printed electrode immobilized by uricase for the detection of salivary uric acid
    Shi, Weishan
    Li, Jing
    Wu, Jie
    Wei, Qianying
    Chen, Cuili
    Bao, Ning
    Yu, Chunmei
    Gu, Haiying
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (26) : 7275 - 7283
  • [22] Amperometric acetylcholine biosensor based on self-assembly of gold nanoparticles and acetylcholinesterase on the sol-gel/multi-walled carbon nanotubes/choline oxidase composite-modified platinum electrode
    Hou, Shihua
    Ou, Zhongmin
    Chen, Qiang
    Wu, Baoyan
    BIOSENSORS & BIOELECTRONICS, 2012, 33 (01): : 44 - 49
  • [23] Construction of an amperometric D-amino acid biosensor based on D-amino acid oxidase/carboxylated mutliwalled carbon nanotube/copper nanoparticles/polyalinine modified gold electrode
    Lata, Suman
    Batra, Bhawna
    Kumar, Pankaj
    Pundir, C. S.
    ANALYTICAL BIOCHEMISTRY, 2013, 437 (01) : 1 - 9
  • [24] Study of a reagent- and mediatorless biosensor for D-amino acids based on co-immobilized D-amino acid oxidase and peroxidase in carbon paste electrodes
    Johansson, Elisabeth
    Marko-Varga, Gyorgy
    Gorton, Lo
    Journal of Biomaterials Applications, 1993, 8 (02) : 146 - 173
  • [25] An ultra-sensitive uric acid second generation biosensor based on chemical immobilization of uricase on functionalized multiwall carbon nanotube grafted palm oil fiber in the presence of a ferrocene mediator
    Deffo, Gullit
    Hazarika, Ranjit
    Ngaha, Marcel Cedric Deussi
    Basumatary, Mwina
    Kalita, Shyamali
    Hussain, Nayab
    Njanja, Evangeline
    Puzari, Panchanan
    Ngameni, Emmanuel
    ANALYTICAL METHODS, 2023, 15 (20) : 2456 - 2466
  • [26] Hydrothermally synthesized carboxylic acid functionalized multiwalled carbon nanotubes grafted MoS2 based hybrid composites: Efficient uranium (VI) scavenging sorbents in columns, fabric and matrix membrane systems
    Singh, Satvir
    Sharma, Sandeep
    Bajwa, B. S.
    Kaur, Inderpreet
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2022, 10 (06):
  • [27] An Amperometric Biosensor Based on Ascorbate Oxidase Immobilized in Poly(3,4-ethylenedioxythiophene)/Multi-Walled Carbon Nanotubes Composite Films for the Determination of L-Ascorbic Acid
    Liu, Ming
    Wen, Yangping
    Xu, Jingkun
    He, Haohua
    Li, Dong
    Yue, Ruirui
    Liu, Guodong
    ANALYTICAL SCIENCES, 2011, 27 (05) : 477 - 482
  • [28] An Amperometric Biosensor Based on Ascorbate Oxidase Immobilized in Poly(3,4-ethylenedioxythiophene)/Multi-Walled Carbon Nanotubes Composite Films for the Determination of l-Ascorbic Acid
    Ming Liu
    Yangping Wen
    Jingkun Xu
    Haohua He
    Dong Li
    Ruirui Yue
    Guodong Liu
    Analytical Sciences, 2011, 27 : 477 - 482