Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry

被引:4
|
作者
Trattner, Sigal [1 ,2 ]
Cheng, Bin [3 ]
Pieniazek, Radoslaw L. [2 ,4 ]
Hoffmann, Udo [5 ,6 ]
Douglas, Pamela S. [7 ]
Einstein, Andrew J. [1 ,2 ,8 ]
机构
[1] Columbia Univ, Med Ctr, Dept Med, Div Cardiol, New York, NY 10032 USA
[2] New York Presbyterian Hosp, New York, NY 10032 USA
[3] Columbia Univ, Mailman Sch Publ Hlth, Dept Biostat, New York, NY 10032 USA
[4] Columbia Univ, Med Ctr, Ctr Radiol Res, New York, NY 10032 USA
[5] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[6] Harvard Univ, Sch Med, Boston, MA 02114 USA
[7] Duke Univ, Dept Med, Div Cardiol, Durham, NC 27715 USA
[8] Columbia Univ, Med Ctr, Dept Radiol, New York, NY 10032 USA
关键词
effective dose; MOSFET; computer tomography; dosimetry; sample size; CT ANGIOGRAPHY; PHANTOM; TECHNOLOGY;
D O I
10.1118/1.4868693
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen-pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence. (c) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Calibration and error analysis of metal-oxide-semiconductor field-effect transistor dosimeters for computed tomography radiation dosimetry
    Trattner, Sigal
    Prinsen, Peter
    Wiegert, Jens
    Gerland, Elazar-Lars
    Shefer, Efrat
    Morton, Tom
    Thompson, Carla M.
    Yagil, Yoad
    Cheng, Bin
    Jambawalikar, Sachin
    Al-Senan, Rani
    Amurao, Maxwell
    Halliburton, Sandra S.
    Einstein, Andrew J.
    MEDICAL PHYSICS, 2017, 44 (12) : 6589 - 6602
  • [2] Metal-oxide-semiconductor field-effect transistor junction requirements
    Duane, Michael
    Lynch, William
    Journal of Vacuum Science & Technology B: Microelectronics Processing and Phenomena, 1998, 16 (01):
  • [3] BALLISTIC METAL-OXIDE-SEMICONDUCTOR FIELD-EFFECT TRANSISTOR
    NATORI, K
    JOURNAL OF APPLIED PHYSICS, 1994, 76 (08) : 4879 - 4890
  • [4] Reconsideration of effective channel length for metal-oxide-semiconductor field-effect transistor
    Terada, Kazuo
    Sanai, Kazuhiko
    Tsuji, Katsuhiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (06)
  • [5] Metal-oxide-semiconductor field-effect transistor with a vacuum channel
    Srisonphan, Siwapon
    Jung, Yun Suk
    Kim, Hong Koo
    NATURE NANOTECHNOLOGY, 2012, 7 (08) : 504 - 508
  • [6] Other transistor: Early history of the metal-oxide-semiconductor field-effect transistor
    Coll. of Engineering and Mathematics, University of Vermont, 109 Votey Building, Burlington, VT 05405-0156, United States
    Eng Sci Educ J, 5 (233-240):
  • [7] The demonstration of the magnetic Ge metal-oxide-semiconductor field-effect transistor
    Liao, M. -H.
    Huang, S. -C.
    AIP ADVANCES, 2015, 5 (02):
  • [8] Probing the density of states in a metal-oxide-semiconductor field-effect transistor
    Calvet, L. E.
    Snyder, J. P.
    Wernsdorfer, W.
    PHYSICAL REVIEW B, 2008, 78 (19)
  • [9] Verification of the plan dosimetry for high dose rate brachytherapy using metal-oxide-semiconductor field effect transistor detectors
    Qi, Zhen-Yu
    Deng, Xiao-Wu
    Huang, Shao-Min
    Lu, Jie
    Lerch, Michael
    Cutajar, Dean
    Rosenfeld, Anatoly
    MEDICAL PHYSICS, 2007, 34 (06) : 2007 - 2013
  • [10] Complementary carbon nanotube metal-oxide-semiconductor field-effect transistors with localized solid-state extension doping
    Zhang, Zichen
    Passlack, Matthias
    Pitner, Gregory
    Natani, Shreyam
    Su, Sheng-Kai
    Chao, Tzu-Ang
    Liew, San Lin
    Hou, Vincent D. -H.
    Hsu, Chen-Feng
    Shipley, Wade E.
    Safron, Nathaniel
    Doornbos, Gerben
    Lee, Tsung-En
    Radu, Iuliana
    Kummel, Andrew C.
    Bandaru, Prabhakar
    Wong, H. -S. Philip
    NATURE ELECTRONICS, 2023, 6 (12) : 999 - 1008