Performance of Iterative Image Reconstruction in CT of the Paranasal Sinuses: A Phantom Study

被引:53
|
作者
Schulz, B. [1 ]
Beeres, M. [1 ]
Bodelle, B. [1 ]
Bauer, R. [1 ]
Al-Butmeh, F. [1 ]
Thalhammer, A. [1 ]
Vogl, T. J. [1 ]
Kerl, J. M. [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
DOSE REDUCTION; QUALITY; ANGIOGRAPHY; ALGORITHM;
D O I
10.3174/ajnr.A3339
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: CT in low dose technique is the criterion standard imaging modality for evaluation of the paranasal sinus. Our aim was to evaluate the dose-reduction potential of a recently available sinogram-affirmed iterative reconstruction technique, regarding noise, image quality, and time duration when evaluating this region. MATERIALS AND METHODS: CT was performed on a phantom head at different tube voltages (120 kV, 100 kV) and currents (100 mAs, 50 mAs, 25 mAs). Each protocol was reconstructed (in soft tissue and bony kernel) by using standard filtered back-projection and 5 different SAFIRE strengths, and image noise was evaluated. Subjective image quality was evaluated on noise-aligned image triplets acquired at tube currents of 100% (FBP), 50% (SAFIRE), and 25% (SAFIRE) by using a 5-point scale (1 = worst, 5 = best). The time duration for image reconstruction was noted for calculations with FBP and SAFIRE. RESULTS: SAFIRE reduced image noise by 15%-85%, depending on the iterative strength, rendering kernel, and dose parameters. Noise reduction was stronger at a bone kernel algorithm both in 1- and 3-mm images (P < .05). Subjective quality evaluation of the noise-adapted images showed preference for those acquired at 100% tube current with FBP (4.7-5.0) versus 50% dose with SAFIRE (3.4-4.4) versus 25% dose with SAFIRE (2.0-3.1). The time duration for FBP image sets was 2.9-6.6 images per second versus SAFIRE with 0.9-1.6 images per second. CONCLUSIONS: For CT of the paranasal sinus, SAFIRE algorithms are suitable for image-noise reduction. Because image quality decreases with dosage, careful choice of the appropriate iterative method is necessary to achieve an optimal balance between image noise and quality.
引用
收藏
页码:1072 / 1076
页数:5
相关论文
共 50 条
  • [1] CT iterative reconstruction in image space: A phantom study
    Ghetti, C.
    Ortenzia, O.
    Serreli, G.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02): : 161 - 165
  • [2] Reducing the dose of CT of the paranasal sinuses: potential of an iterative reconstruction algorithm
    Schaafs, Lars-Arne
    Lenk, Julian
    Hamm, Bernd
    Niehues, Stefan Markus
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (07)
  • [3] Model-based iterative reconstruction in CT of paranasal sinuses in cystic fibrosis
    Lin, S.
    Lau, K. K.
    CLINICAL RADIOLOGY, 2021, 76 (12) : 930 - 934
  • [4] Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality
    Bulla, Stefan
    Blanke, Philipp
    Hassepass, Frederike
    Krauss, Tobias
    Winterer, Jan Thorsten
    Breunig, Christine
    Langer, Mathias
    Pache, Gregor
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2246 - 2250
  • [5] Image quality with iterative reconstruction techniques in CT of the lungs-A phantom study
    Andersen, Hilde Kjernlie
    Volgyes, David
    Martinsen, Anne Latrine Trgde
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2018, 5 : 35 - 40
  • [6] Multislice spiral CT and secondary reconstruction of the paranasal sinuses
    Mack, MG
    Balzer, JO
    Baghi, M
    Schafti, S
    Herzog, C
    Vogl, TJ
    RADIOLOGY, 2002, 225 : 564 - 564
  • [7] CT image quality in sinogram affirmed iterative reconstruction phantom study - is there a point of diminishing returns?
    Infante, Juan C.
    Liu, Yu
    Rigsby, Cynthia K.
    PEDIATRIC RADIOLOGY, 2017, 47 (03) : 333 - 341
  • [8] CT image quality in sinogram affirmed iterative reconstruction phantom study – is there a point of diminishing returns?
    Juan C. Infante
    Yu Liu
    Cynthia K. Rigsby
    Pediatric Radiology, 2017, 47 : 333 - 341
  • [9] Dose reduction and image quality in CT examinations using an iterative reconstruction algorithm: a phantom study
    Guariglia, S.
    Meliado, G.
    Zivelonghi, E.
    Pinali, L.
    Montemezzi, S.
    Cavedon, C.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [10] LOW-DOSE COMPUTED TOMOGRAPHY OF THE PARANASAL SINUSES: PERFORMANCE OF TWO DIFFERENT ITERATIVE RECONSTRUCTION ALGORITHMS
    Schaafs, Lars-Arne
    Pfeil, Julian
    Koehlitz, Torsten
    Hamm, Bernd
    Niehues, Stefan Markus
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (03) : 386 - 392