Importance of SPECT/CT for knee and hip joint Prostheses

被引:0
|
作者
Strobel, K. [1 ]
Steurer-Dober, I. [1 ]
Huellner, M. W. [1 ]
Veit-Haibach, P. [1 ]
Allgayer, B. [1 ]
机构
[1] Luzerner Kantonsspital, Inst Nukl Med & Rontgendiagnost, CH-6000 Luzern 16, Switzerland
来源
RADIOLOGE | 2012年 / 52卷 / 07期
关键词
Hip arthroplasty; Knee arthroplasty; Infection; Loosening; Periprosthetic fracture; SCINTIGRAPHIC EVALUATION; ACETABULAR COMPONENT; BONE-SCINTIGRAPHY; FEMORAL COMPONENT; REPLACEMENT; COMPLICATIONS; ARTHROPLASTY; ARTHROGRAPHY; RADIOGRAPHY; ACCURACY;
D O I
10.1007/s00117-011-2270-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Complications, such as loosening or infections are common problems after hip or knee arthroplasty. If conventional X-rays are equivocal bone scintigraphy is the classical second-line imaging modality. Single photon emission computed tomography/computed tomography (SPECT/CT) offers metabolic and morphologic information in one imaging step and is becoming increasingly more available in larger hospitals. The SPECT/CT procedure is a promising method and is increasingly being used in daily routine to evaluate joint arthroplasty. The additional benefit compared with classical conventional bone scintigraphy has to be evaluated in further prospective studies. In our hospital SPECT/CT regularly gives important additional information regarding prosthetic joint complications. SPECT/CT is increasingly being used as the second step imaging standard modality if conventional X-rays are equivocal.
引用
收藏
页码:629 / 635
页数:7
相关论文
共 50 条
  • [31] Development of hip joint prostheses with modular stems
    Bae, Ji-Yong
    Farooque, Umar
    Lee, Kyung-won
    Kim, Gyu-Ha
    Jeon, Insu
    Yoon, Taek-Rim
    [J]. COMPUTER-AIDED DESIGN, 2011, 43 (09) : 1173 - 1180
  • [32] Evaluation of acetabular wear in hip joint prostheses
    Pietrabissa, R
    Raimondi, M
    Quaglini, V
    Contro, R
    [J]. COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 131 - 138
  • [33] EFFECTS OF LUBRICATION IN HIP-JOINT PROSTHESES
    UNSWORTH, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (02): : 253 - 268
  • [34] KNEE-JOINT PROSTHESES - INDICATION AND LIMITS
    LORTATJACOB, A
    BENOIT, J
    [J]. REVUE DE MEDECINE, 1977, 18 (10): : 485 - 493
  • [35] In-vivo-Measurement of Knee Joint Prostheses
    不详
    [J]. JOURNAL FUR MINERALSTOFFWECHSEL & MUSKULOSKELETTALE ERKRANKUNGEN, 2018, 25 (03): : 108 - 108
  • [36] Study of contact with artificial hip joint prostheses
    Cananau, S.
    Tudor, A.
    [J]. UPB Scientific Bulletin, Series D: Mechanical Engineering, 2001, 63 (03): : 39 - 44
  • [37] STRESSES IN HINGED KNEE-JOINT PROSTHESES
    MIEHLKE, R
    [J]. SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 1983, 12 (02) : 188 - 188
  • [38] In-vivo-Measurement of Knee Joint Prostheses
    不详
    [J]. TRAUMA UND BERUFSKRANKHEIT, 2018, 20 (03) : 195 - 195
  • [39] Diagnostik Value of Quantitative 99mTc-DPD-SPECT/CT for the detection of prosthetic loosening in patients with hip-and knee joint replacement
    Braun, M.
    Cachovan, M.
    Pagenstert, G.
    Vija, A. H.
    Wild, D.
    Kretzschmar, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S492 - S493
  • [40] Recent advances in imaging of hip and knee prostheses DISCUSSION
    Battin, M. Jacques
    Dubousset, M. Jean
    Mornex, M. Rene
    Menkes, M. Charles-Joel
    Cabanis, M. Emmanuel-Alain
    Chouard, M. Claude-Henri
    [J]. BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2011, 195 (03): : 626 - 628