Effective Dose Calculations in Conventional Diagnostic X-Ray Examinations for Patients in Major Sudanese Hospitals

被引:0
|
作者
Suliman, I. I. [1 ]
Habbani, F. I. [2 ]
机构
[1] Sudan Atom Energy Commiss, Radiat Safety Inst, Gamma St,POB 3001, Khartoum, Sudan
[2] Univ Khartoum, Fac Sci, Dept Phys, Khartoum, Sudan
关键词
effective dose; diagnostic radiology; energy imparted;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work was to compare two methods used for effective dose (ED) calculation in conventional diagnostic x-ray examinations and to analyze effective dose distributions among radiological departments under study. The study was performed in four major hospitals in Khartoum area, Sudan, covering eight x-ray units and a sample of 325 patients. Two approaches were used for effective dose calculation: In the first approach, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for chest PA, Skull AP/PA, Skull LAT, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations. The ED values were then calculated from the obtained ESD values using NRPB-SR262 Monte Carlo data and XDOSE software. In the second approach, the energy imparted to patients in the same x-ray examinations was computed using values for entrance skin exposure, half- value layer and exposure area. Effective doses were then calculated from energy imparted using ED conversion factors proposed by other authors. The results of ED values calculated using the two approaches were in good agreement between themselves and with data reported in the literature. The mean ED values calculated using the Monte Carlo data and XDOSE software were found to be 29.9, 44.1, 8.91, 232.5, 224.5 and 93.6 mu Sv for chest PA, Skull AP/PA, Skull LAT, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations, respectively. Almost all ED values were below the corresponding DRLs established elsewhere, except for chest PA examination which exhibited comparable mean ED values. The study is expected to increase the awareness among the medical professionals and members of the public on the status of radiological protection in Sudan.
引用
收藏
页码:2087 / +
页数:3
相关论文
共 50 条
  • [31] PREPARING PATIENTS FOR X-RAY EXAMINATIONS
    SCOGGINS, MLC
    AMERICAN JOURNAL OF NURSING, 1957, 57 (01) : 76 - 79
  • [32] PATIENT DOSES IN COMMON DIAGNOSTIC X-RAY EXAMINATIONS
    Metaxas, Vasileios, I
    Messaris, Gerasimos A.
    Lekatou, Aristea N.
    Petsas, Theodore G.
    Panayiotakis, George S.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (01) : 12 - 27
  • [33] The use of low dosage X-ray (Lodox/Statscan) in major trauma: Comparison between low dose X-ray and conventional X-ray techniques
    Boffard, Kenneth D.
    Goosen, Jacques
    Plani, Frank
    Degiannis, Elias
    Potgieter, Herman
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (06): : 1175 - 1181
  • [34] Ultra low dose X-ray spinal examinations
    Fessler, P
    Prevot, G
    Hilt, B
    RESEARCH INTO SPINAL DEFORMITIES 3, 2002, 88 : 191 - 195
  • [35] Hardware monitoring of effective doses in X-ray examinations
    Stavitskii R.V.
    Zhanina T.V.
    Murashov A.I.
    Kovalev A.S.
    Lebedev L.A.
    Mamaev S.V.
    Biomedical Engineering, 1999, 33 (4) : 198 - 199
  • [36] A COMPARATIVE STUDY OF ORGAN DOSES ASSESSMENT FOR PATIENTS UNDERGOING CONVENTIONAL X-RAY EXAMINATIONS: PHANTOM EXPERIMENTS VS. CALCULATIONS
    Golikov, V.
    Barkovsky, A.
    Wallstrom, E.
    Cederblad, A.
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (02) : 223 - 234
  • [37] A survey of annual effective and genetically significant dose from conventional X-ray examinations in 10 counties in Khorasan province-Iran
    Saffar, M. Hajizadeh
    Nekoee, S.
    Saffar, E. Hajizadeh
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2007, 5 (03): : 113 - 118
  • [38] Determination of dose load and dose-effect curves in patients undergoing X-ray examinations
    Stavitskii R.V.
    Lebedev L.A.
    Zhanina T.V.
    Seliverstov A.A.
    Lebedenko I.M.
    Mikheichev A.S.
    Biomedical Engineering, 1999, 33 (5) : 235 - 238
  • [39] Evaluation of dose to tooth enamel from medical diagnostic X-ray examinations at Mayak PA
    Wieser, A.
    Vasilenko, E.
    Zankl, M.
    Greiter, M.
    Ulanovsky, A.
    Sabayev, A.
    Knyazev, V.
    Zahrov, R.
    RADIATION MEASUREMENTS, 2011, 46 (09) : 808 - 812
  • [40] ESTIMATION OF EFFECTIVE DOSE TO THE PATIENT DURING MEDICAL X-RAY EXAMINATIONS FROM MEASUREMENTS OF THE DOSE AREA PRODUCT
    LEHERON, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (11): : 2117 - 2126