Effective Dose Calculations in Conventional Diagnostic X-Ray Examinations for Patients in Major Sudanese Hospitals

被引:0
|
作者
Suliman, I. I. [1 ]
Habbani, F. I. [2 ]
机构
[1] Sudan Atom Energy Commiss, Radiat Safety Inst, Gamma St,POB 3001, Khartoum, Sudan
[2] Univ Khartoum, Fac Sci, Dept Phys, Khartoum, Sudan
关键词
effective dose; diagnostic radiology; energy imparted;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work was to compare two methods used for effective dose (ED) calculation in conventional diagnostic x-ray examinations and to analyze effective dose distributions among radiological departments under study. The study was performed in four major hospitals in Khartoum area, Sudan, covering eight x-ray units and a sample of 325 patients. Two approaches were used for effective dose calculation: In the first approach, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for chest PA, Skull AP/PA, Skull LAT, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations. The ED values were then calculated from the obtained ESD values using NRPB-SR262 Monte Carlo data and XDOSE software. In the second approach, the energy imparted to patients in the same x-ray examinations was computed using values for entrance skin exposure, half- value layer and exposure area. Effective doses were then calculated from energy imparted using ED conversion factors proposed by other authors. The results of ED values calculated using the two approaches were in good agreement between themselves and with data reported in the literature. The mean ED values calculated using the Monte Carlo data and XDOSE software were found to be 29.9, 44.1, 8.91, 232.5, 224.5 and 93.6 mu Sv for chest PA, Skull AP/PA, Skull LAT, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations, respectively. Almost all ED values were below the corresponding DRLs established elsewhere, except for chest PA examination which exhibited comparable mean ED values. The study is expected to increase the awareness among the medical professionals and members of the public on the status of radiological protection in Sudan.
引用
收藏
页码:2087 / +
页数:3
相关论文
共 50 条
  • [1] Effective dose calculations in conventional diagnostic X-ray examinations for adult and paediatric patients in a large Italian hospital
    Compagnone, G
    Pagan, L
    Bergamini, C
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 164 - 167
  • [2] Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals
    Johnston, DA
    Brennan, PC
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (868): : 396 - 402
  • [3] ESTIMATION OF EFFECTIVE DOSE TO PEDIATRIC PATIENTS UNDERGOING X-RAY EXAMINATIONS
    Shatskiy, Ilya
    Golikov, Vladislav
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 131 - 132
  • [4] ESTIMATION OF THE ORGAN AND EFFECTIVE DOSE TO PATIENTS UNDERGOING MEDICAL DIAGNOSTIC X-RAY EXAMINATIONS IN SAUDI ARABIA
    Ababneh, Zaid Q.
    Almusallam, Moayed
    Alfajri, Ibrahim
    Ababneh, Anas M.
    Aljarrah, Khaled M.
    Tries, Mark A.
    Al Anazi, Nawaf
    RADIATION PROTECTION DOSIMETRY, 2021, 194 (01) : 1 - 8
  • [5] DOSE AND IMAGE QUALITY CALCULATIONS FOR CHEST X-RAY EXAMINATIONS
    KOBLINGE.L
    ZARAND, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 712 - &
  • [6] Assessment of Patient Radiation Dose during Conventional Diagnostic X-ray Examinations in Three Public Hospitals in Northern Jordan using TLDs
    Ababneh, Zaid Q.
    Ababneh, Anas M.
    Hani, Majd S. Bani
    Ababneh, Riad S.
    Aljarrah, Khaled M.
    HEALTH PHYSICS, 2020, 118 (06): : 593 - 599
  • [7] Patient doses in different projections of conventional diagnostic X-ray examinations
    Liu, Haikuan
    Zhuo, Weihai
    Chen, Bo
    Yi, Yanling
    Li, Dehong
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (03) : 334 - 338
  • [8] DIAGNOSTIC REFERNCE LEVELS AND PATIENT DOSES FOR ADULT PATIENTS IN CONVENTIONAL X-RAY EXAMINATIONS IN LATVIA
    Katlapa, Agnese
    Zalcmanis, Emils
    MEDICAL PHYSICS IN THE BALTIC STATES, 2019, : 31 - 33
  • [9] EXAMINATIONS ON EFFECTIVE FOCAL SPOT SIZE IN DIAGNOSTIC X-RAY TUBES
    ANDERSSON, O
    RADIOLOGIA DIAGNOSTICA, 1974, 15 (04) : 535 - 542
  • [10] A phantom study showing the importance of compression in conventional diagnostic X-ray examinations
    Olsson, M. -L.
    Tingberg, A.
    Mattsson, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 78 - 80