Energy transfer and energy saving potentials of air-to-air membrane energy exchanger for ventilation in cold climates

被引:42
|
作者
Liu, Peng [1 ]
Alonso, Maria Justo [2 ]
Mathisen, Hans Martin [1 ]
Simonson, Carey [3 ]
机构
[1] NTNU, Dept Energy & Proc Engn, Trondheim, Norway
[2] SINTEF Bldg & Infrastruct, Trondheim, Norway
[3] Univ Saskatchewan, Dept Mech Engn, Saskatoon, SK, Canada
关键词
Heat and mass transfer; Membrane energy exchanger; Frost; Heat exchanger; Ventilation; HVAC; MASS-TRANSFER; ENTHALPY EXCHANGER; MOISTURE TRANSFER; HEAT-EXCHANGER; RECOVERY VENTILATOR; PERFORMANCE; FLOW; PERMEATION; MODEL;
D O I
10.1016/j.enbuild.2016.11.047
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Frosting occurring inside heat exchangers degrades the exchangers' performance and reduces energy recovery in cold climates. The moisture transport in membrane energy exchangers (MEE) provides a great potential to increase frost tolerance and decrease energy consumption by the air handling units (AHU). In addition, the moisture recovery in MEEs tends to improve the thermal comfort by adding moisture to the indoor dry air. However, applications of MEEs for cold climates are less known compared to their use in hot and humid climates as independent cooling and dehumidification. The open literatures dealing with heat and mass transfer of the MEEs for cold climates are scarce and acute. This research aims to investigate heat and moisture transfer, and energy saving potentials of MEEs compared to the sensible-only heat exchanger (HE). The applicability of transforming heat and moisture transfer analysis carried out for hot and humid conditions to cold climates is examined. The study attempts to "translate" conventional sensible-only HE correlations to the MEEs. Knowledge and data of heat exchangers are transformed to MEEs through analysing the boundary conditions of heat and mass transfer in both MEE and HE. This transformation can reduce needs of relying on computational fluid dynamics (CFD) to analyse heat and mass transfer in MEEs. As one of most important advantages of adopting MEE in cold climates, frosting reduction by the MEE is determined and compared for a specific MEE and HE in the heating season of Oslo (Norway). The energy consumption by the AHU equipped with the MEE is compared to the AHU with HE under different airflow rates. The MEE is able to significantly reduce the energy consumption by preheating and post-conditioning (reheating and humidifying) when there is frosting risk in MEE or HE for Oslo climate. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:95 / 108
页数:14
相关论文
共 50 条
  • [21] Energy cost models for air supported sports hall in cold climates considering energy efficiency
    Nord, Natasa
    Mathisen, Hans Martin
    Cao, Guangyu
    RENEWABLE ENERGY, 2015, 84 : 56 - 64
  • [22] Uncertainty quantification of exchange efficiency in membranebased air-to-air energy exchanger cores: Repetitive manufacturing and experiments
    Qiu, Shunian
    Che, Yanjin
    Chang, Yuan
    Wang, Zhechao
    Li, Zhenhai
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 59
  • [23] Performance Improvement of Membrane Energy Exchanger Using Ultrasound for Heating, Ventilation, and Air Conditioning Application
    Gurubalan, A.
    Maiya, M. P.
    Geoghegan, Patrick
    Simonson, Carey J.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2022, 14 (05)
  • [24] Vapor-selective active membrane energy exchanger with mechanical ventilation and indoor air recirculation
    Fix, Andrew J.
    Pamintuan, Bryan C.
    Braun, James E.
    Warsinger, David M.
    APPLIED ENERGY, 2022, 312
  • [25] Modelling heat and mass transfer in a membrane-based air-to-air enthalpy exchanger
    Dugaria, S.
    Moro, L.
    Del Col, D.
    33RD UIT (ITALIAN UNION OF THERMO-FLUID DYNAMICS) HEAT TRANSFER CONFERENCE, 2015, 655
  • [26] Energy Saving Opportunities of Energy Efficient Air Nozzles
    Slootmaekers, Tim
    Slaets, Peter
    Bartsoen, Torn
    Malfait, Lieven
    Vanierschot, Maarten
    INTERNATIONAL CONFERENCE OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING 2015 (ICCMSE 2015), 2015, 1702
  • [27] EMPIRICAL STUDY OF AN AIR-TO-AIR HEAT PIPE HEAT EXCHANGER IN TROPICAL CLIMATES
    Yau, Y. H.
    Ahmadzadehtalatapeh, M.
    EXPERIMENTAL HEAT TRANSFER, 2011, 24 (04) : 313 - 334
  • [28] ENERGY-SAVING RETROFITTING OF HOUSES IN COLD CLIMATES
    Yildiz, Yusuf
    Ozbalta, Turkan Goksal
    Eltez, Asude
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2014, 34 (01) : 53 - 61
  • [29] Unsteady analysis of the cold energy storage heat exchanger in a liquid air energy storage system
    Chen, Jiaxiang
    Yang, Luwei
    An, Baolin
    Hu, Jianying
    Wang, Junjie
    ENERGY, 2022, 242
  • [30] Energy saving potential of ventilation systems with exhaust air heat recovery
    Zemitis, J.
    Borodinecs, A.
    4TH INTERNATIONAL CONFERENCE ON INNOVATIVE MATERIALS, STRUCTURES AND TECHNOLOGIES (IMST 2019), 2019, 660