Endoscopic ultrasound and positron emission tomography for lung cancer staging

被引:11
|
作者
Sawhney, Mandeep S.
Kratzke, Robert A.
Lederle, Frank A.
Holmstrom, Amy M.
Nelson, Douglas B.
Kelly, Rosemary F.
机构
[1] Minneapolis VA Med Ctr, Gastroenterol Sect, Minneapolis, MN 55417 USA
[2] Minneapolis VA Med Ctr, Ctr Epidemiol & Clin Res, Minneapolis, MN 55417 USA
[3] Univ Minnesota, Sect Hematol Oncol & Transplantat, Minneapolis, MN USA
[4] Univ Minnesota, Sect Cardiothorac Surg, Minneapolis, MN USA
关键词
D O I
10.1016/j.cgh.2006.03.012
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & Aims: Accurate assessment of mediastinal lymph nodes is vital for optimum treatment allocation in lung cancer patients. Currently available strategies fail to identify many patients with advanced mediastinal disease, resulting in unnecessary surgery. We prospectively compared 2 promising new modalities, positron emission tomography (PET) and endoscopic ultrasound (EUS), for staging mediastinal lymph nodes. Methods: Consenting patients with lung cancer who also were suitable candidates for surgery were enrolled in the study. Patients underwent both PET and EUS. Outcomes were analyzed by surgery results or follow-up with serial imaging. Results: Seventy-two eligible patients were enrolled, and adequate data were available for 65 patients. The final diagnosis was based on tissue analysis in 59 patients and 1-year radiologic follow-up evaluation in 6 patients. PET correctly diagnosed mediastinal lymph node status in 77% of patients, and EUS fine-needle aspiration was correct in 94% of patients (P =.012). The overall sensitivity, specificity, and accuracy of PET. were 61%, 91%, and 77% compared with 87%, 100%, and 9.4% for EUS. We estimated that EUS obviated a surgical procedure in 55% (95% confidence interval, 40%-69%) of patients with radiologic evidence of mediastinal metastasis, and in 22% (95% confidence interval, 10%-41%) of patients without radiologic evidence of mediastinal metastasis. Conclusions: EUS fine-needle aspiration was more accurate than PET in staging mediastinal lymph nodes in lung cancer patients, and resulted in a substantial reduction in mediastinoscopy and thoracotomy.
引用
收藏
页码:846 / 851
页数:6
相关论文
共 50 条
  • [1] Endoscopic ultrasound, positron emission tomography, and computerized tomography for lung cancer
    Fritscher-Ravens, A
    Davidson, BL
    Hauber, HP
    Bohuslavizki, KH
    Bobrowski, C
    Lund, C
    Knöfel, WT
    Soehendra, N
    Brandt, L
    Pepe, MS
    Pforte, A
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 168 (11) : 1293 - 1297
  • [2] Endoscopic ultrasound is more accurate than positron emission tomography in the staging of nonsmall cell lung cancer
    Kelly, RF
    Sullivan, VV
    Nelson, DB
    Holmstrom, AM
    Lederle, FA
    Sawhney, MS
    [J]. CHEST, 2005, 128 (04) : 171S - 171S
  • [3] Positron emission tomography/computed tomography for lung cancer staging
    de Guevara H, David Ladron
    Furnaro L, Francisca
    Yevenes A, Sebastian
    Clavero R, Jose Miguel
    Lazo P, David
    Rodriguez D, Patricio
    Piottante B, Antonio
    Pefaur D, Raul
    Pardo B, Claudio
    [J]. REVISTA MEDICA DE CHILE, 2015, 143 (01) : 22 - 29
  • [4] Comparison of Positron Emission Tomography, Computed Tomography, and Endoscopic Ultrasound in the Initial Staging of Patients with Esophageal Cancer
    Val J. Lowe
    Fargol Booya
    J. G. Fletcher
    Mark Nathan
    Eric Jensen
    Brian Mullan
    Eric Rohren
    Maurits J. Wiersema
    Enrique Vazquez-Sequeiros
    Joseph A. Murray
    Mark S. Allen
    Michael J. Levy
    Jonathan E. Clain
    [J]. Molecular Imaging and Biology, 2005, 7 : 422 - 430
  • [5] Comparison of positron emission tomography, computed tomography, and endoscopic ultrasound in the initial staging of patients with esophageal cancer
    Lowe, VJ
    Booya, F
    Fletcher, JG
    Nathan, M
    Jensen, E
    Mullan, B
    Rohren, E
    Wiersema, MJ
    Vazquez-Sequeiros, E
    Murray, JA
    Allen, MS
    Levy, MJ
    Clain, JE
    [J]. MOLECULAR IMAGING AND BIOLOGY, 2005, 7 (06) : 422 - 430
  • [6] New approaches to gastric cancer staging:Beyond endoscopic ultrasound,computed tomography and positron emission tomography
    Hyuk Yoon
    Dong Ho Lee
    [J]. World Journal of Gastroenterology, 2014, (38) : 13783 - 13790
  • [7] New approaches to gastric cancer staging: Beyond endoscopic ultrasound, computed tomography and positron emission tomography
    Yoon, Hyuk
    Lee, Dong Ho
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (38) : 13783 - 13790
  • [8] Role of positron emission tomography in the staging of lung cancer
    Schiepers, C
    [J]. LUNG CANCER, 1997, 17 : S29 - S35
  • [9] Value of positron emission tomography for lung cancer staging
    Albes, JM
    Dohmen, BM
    Schott, U
    Schülen, E
    Wehrmann, M
    Ziemer, G
    [J]. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 2002, 28 (01): : 55 - 62
  • [10] STAGING OF LUNG-CANCER BY POSITRON EMISSION TOMOGRAPHY
    POUNDS, TR
    VALK, PE
    HOPKINS, DM
    MYERS, RA
    HASEMAN, MK
    LUTRIN, CL
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P76 - P76