Prediction of body water compartments in preterm infants by bioelectrical impedance spectroscopy

被引:35
|
作者
Collins, C. T. [1 ,2 ,3 ]
Reid, J. [1 ,2 ,3 ]
Makrides, M. [1 ,2 ,3 ]
Lingwood, B. E. [4 ]
McPhee, A. J. [5 ]
Morris, S. A. [6 ]
Gibson, R. A. [7 ]
Ward, L. C. [8 ]
机构
[1] Womens & Childrens Hosp, Womens & Childrens Hlth Res Inst, FOODplus Res Ctr, Adelaide, SA 5042, Australia
[2] Flinders Med Ctr, Adelaide, SA 5042, Australia
[3] Univ Adelaide, Discipline Paediat, Adelaide, SA, Australia
[4] Univ Queensland, Royal Brisbane & Womens Hosp, UQ Ctr Clin Res, Brisbane, Qld, Australia
[5] Womens & Childrens Hosp, Dept Neonatal Med, Adelaide, SA 5042, Australia
[6] Flinders Med Ctr, Ctr Perinatal Med, Adelaide, SA, Australia
[7] Univ Adelaide, Sch Agr Food & Wine, FOODplus Res Ctr, Adelaide, SA, Australia
[8] Univ Queensland, Sch Chem & Mol Biosci, Brisbane, Qld, Australia
关键词
body composition; electrical impedance; body water; infant newborn; MULTIPLE FREQUENCY BIOIMPEDANCE; BIRTH-WEIGHT INFANTS; DIELECTRIC-PROPERTIES; BIOLOGICAL TISSUES; LIMB STANDARDS; FLUID VOLUME; GROWTH; VALIDATION; RESISTANCE; MASS;
D O I
10.1038/ejcn.2012.164
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
BACKGROUND/OBJECTIVES: To evaluate nutritional interventions in preterm infants, a simple, accurate assessment of the type of growth, that is, change in body composition through the relative contributions of lean body tissue and fat mass to weight gain, is needed. Bioelectrical impedance may provide such a method. The aim of this study was to develop resistivity coefficients appropriate for use in bioelectrical impedance spectroscopy (BIS) analysis of body water volumes in preterm infants. SUBJECTS/METHODS: A total of 99 preterm infants were enrolled (mean gestational age 32 completed weeks). Total body water (TBW) and extracellular water (ECW) were determined using the reference methods of deuterium and bromide dilution. BIS measurements taken at the same time allowed calculation of resistivity coefficients. Predictions of TBW and ECW obtained using these coefficients were then validated against volumes determined using the reference methods in a separate cohort of infants. RESULTS: Data were available for 91 preterm infants. BIS-predicted TBW and ECW correlated well with the measured volumes (Pearson's r(p) = 0.825 and 0.75, respectively). There was a small bias (TBW 10 ml and ECW 40 ml) but large limits of agreement (TBW +/- 650 ml and ECW +/- 360 ml). CONCLUSIONS: BIS appears to have limited clinical utility; however, the relatively small bias means that it may be useful for measurements within a population or for comparisons between groups in which population means rather than individual values are compared.
引用
下载
收藏
页码:S47 / S53
页数:7
相关论文
共 50 条
  • [21] Assessment of bioelectrical impedance analysis for the prediction of total body water in cystic fibrosis
    Richards, ML
    Bell, SC
    Edmiston, KA
    Davies, PSW
    ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION, 2003, 12 (02) : 161 - 165
  • [22] Comparison of ultrasound skinfolds and bioelectrical impedance spectroscopy to predict body composition in breastfed term infants
    Gridneva, Zoya
    Ward, Leigh C.
    Hepworth, Anna R.
    Lai, Ching T.
    Hartmann, Peter E.
    Geddes, Donna T.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2015, 69 : S27 - S27
  • [23] Validation of Bioelectrical Impedance Spectroscopy to Measure Total Body Water in Resistance-Trained
    Kerr, Ava
    Slater, Gary
    Byrne, Nuala
    Chaseling, Janet
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2015, 25 (05) : 494 - 503
  • [24] Assessment of foot-to-foot bioelectrical impedance analysis for the prediction of total body water
    NA Bell
    PD McClure
    RJ Hill
    PSW Davies
    European Journal of Clinical Nutrition, 1998, 52 : 856 - 859
  • [25] IMPEDANCE MEASUREMENTS OF BODY-WATER COMPARTMENTS
    MATTHIE, JR
    WITHERS, P
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (05): : 1167 - 1168
  • [26] Assessment of foot-to-foot bioelectrical impedance analysis for the prediction of total body water
    Bell, NA
    McClure, PD
    Hill, RJ
    Davies, PSW
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1998, 52 (11) : 856 - 859
  • [27] Determination of body water compartments in neonatal foals by use of indicator dilution techniques and multifrequency bioelectrical impedance analysis
    Fielding, C. Langdon
    Magdesian, K. Gary
    Edman, Judy E.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2011, 72 (10) : 1390 - 1396
  • [28] Estimation of total body water from bioelectrical impedance spectroscopy in oncology outpatients receiving radiotherapy and agreement with three prediction equations
    Isenring, E.
    Colombo, M.
    Cross, G.
    Kellett, E.
    Swaney, L.
    JOURNAL OF HUMAN NUTRITION AND DIETETICS, 2009, 22 (01) : 50 - 54
  • [29] POSTNATAL CHANGES OF BODY-WATER COMPARTMENTS IN PRETERM INFANTS WITH RESPIRATORY-DISTRESS SYNDROME
    SHAFFER, SG
    BOWEN, SK
    HALL, RT
    PEDIATRIC RESEARCH, 1986, 20 (04) : A360 - A360
  • [30] BIOELECTRICAL-IMPEDANCE MEASUREMENT OF BODY-WATER
    BOULIER, A
    THOMASSET, AL
    APFELBAUM, M
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 55 (03): : 761 - 762