Fracture load and failure types of different veneered polyetheretherketone fixed dental prostheses

被引:41
|
作者
Taufall, Simon [1 ]
Eichberger, Marlis [1 ]
Schmidlin, Patrick R. [2 ]
Stawarczyk, Bogna [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Sch Dent, Dept Prosthodont, Goethestr 70, D-80336 Munich, Germany
[2] Univ Zurich, Ctr Dent Med, Clin Prevent Dent Periodontol & Cariol, Zurich, Switzerland
关键词
Fracture load; PEEK; Digital veneering; Veneering resin composite; SHEAR BOND STRENGTH; DIFFERENT SURFACE PRETREATMENTS; RESIN COMPOSITE CEMENTS; BEARING CAPACITY; SULFURIC-ACID; PEEK; IMPLANTS; ADHESIVES; IMPACT; FDPS;
D O I
10.1007/s00784-016-1777-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study is to investigate the fracture load of different veneered PEEK 3-unit fixed dental prosthesis (FDPs) after different aging regimens. Congruently anatomically shaped 3-unit FDPs were milled using a master stl-data set and randomly divided into four groups (N = 120, n = 30 per veneering group), which were veneered using different veneering methods: (i) digital veneering with breCAM.HIPC, (ii) conventional veneering with crea.lign, (iii) conventional with crea.lign paste, and (iv) using pre-manufactured veneers visio.lign. The FDPs were then adhesively cemented on a metal abutment and fracture loads were measured in a universal testing machine (1 mm/min) before and after aging (10,000 thermal cycles, 5/55 A degrees C). Two- and one-way ANOVA followed by post hoc Scheff, tests were used for data analysis (p < 0.05). This investigation showed an influence of the veneering method on the fracture load results independent of the aging level. The highest fracture load was measured for the FDPs with digital veneering (1882 +/- 152 N at baseline, 2021 +/- 184 N after thermocycling). The remaining groups showed comparable results, and no impact of thermal aging was observed. Digital and conventional veneers showed cracks in the pontic region starting from the connector area as a main failure type after loading, while the pre-manufactured veneers showed predominantly adhesive failures. The digital veneering method showed the highest fracture load resistance. Thermal aging showed no impact on the fracture load of all tested veneered PEEK 3-unit FDPs. According to this study results, reliable veneering of PEEK FDPs can be achieved with digital veneering.
引用
收藏
页码:2493 / 2500
页数:8
相关论文
共 50 条
  • [21] Fracture behaviour of zirconia ceramic cantilever fixed dental prostheses in vitro
    Gabbert, Olaf
    Ohlmann, Brigitte
    Schmitter, Marc
    Gilde, Herbert
    Ruef, Thomas
    Rammelsberg, Peter
    ACTA ODONTOLOGICA SCANDINAVICA, 2008, 66 (04) : 200 - 206
  • [22] Effect of veneering technique on the fracture resistance of zirconia fixed dental prostheses
    Chaar, M. S.
    Witkowski, S.
    Strub, J. R.
    Att, W.
    JOURNAL OF ORAL REHABILITATION, 2013, 40 (01) : 51 - 59
  • [23] Fracture analysis of randomized implant-supported fixed dental prostheses
    Esquivel-Upshaw, Josephine F.
    Mehler, Alex
    Clark, Arthur E.
    Neal, Dan
    Anusavice, Kenneth J.
    JOURNAL OF DENTISTRY, 2014, 42 (10) : 1335 - 1342
  • [24] Evaluation of photopolymer resins for dental prosthetics fabricated via the stereolithography process at different polymerization temperatures. Part II: Dimensional accuracy and fracture load of fixed dental prostheses
    Lee, Ji -Min
    Son, Keunbada
    Lee, Kyu-Bok
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (02): : 330.e1 - 330.e9
  • [25] Rehabilitation of biting abilities in patients with different types of dental prostheses
    Miyaura, K
    Morita, M
    Matsuka, Y
    Yamashita, A
    Watanabe, T
    JOURNAL OF ORAL REHABILITATION, 2000, 27 (12) : 1073 - 1076
  • [26] Clinical outcomes of veneered zirconia anterior partial fixed dental prostheses: A 12-year prospective clinical trial
    Fernanda Sola-Ruiz, Maria
    Leon-Martine, Raquel
    Labaig-Rueda, Carlos
    Selva-Otalaorrouchi, Eduardo
    Agustin-Panadero, Ruben
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (06): : 846 - 851
  • [27] Outcome of posterior fixed dental prostheses made from veneered zirconia over an observation period of up to 13 years
    Passia, Nicole
    Chaar, M. Sad
    Kern, Matthias
    JOURNAL OF DENTISTRY, 2019, 86 : 126 - 129
  • [28] Fracture Strength of Interim CAD/CAM and Conventional Partial Fixed Dental Prostheses
    Sadid-Zadeh, Ramtin
    Zirkel, Cory
    Makwoka, Seteven
    Li, Rui
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (08): : 720 - 724
  • [29] Fracture behavior of pontics of fiber-reinforced composite fixed dental prostheses
    Perea, Leila
    Matinlinna, Jukka P.
    Tolvanen, Mimmi
    Vallittu, Pekka K.
    DENTAL MATERIALS JOURNAL, 2015, 34 (06) : 746 - 753
  • [30] Fracture Resistance of CAD/CAM Versus Traditional Interim Fixed Dental Prostheses
    Pop, Daniel Alexandru
    Malaescu, R.
    Marsavina, Liviu
    Hosszu, Tiberiu
    Rotar, Raul
    Goguta, Luciana
    Duma, Virgil Florin
    Negrutiu, Meda Lavinia
    Sinescu, Cosmin
    Jivanescu, Anca
    MATERIALE PLASTICE, 2018, 55 (03) : 361 - 363