3-Year clinical evaluation of posterior packable composite resin restorations

被引:24
|
作者
Loguercio, AD
Reis, A
Hernandez, PAG
Macedo, RP
Busato, ALS
机构
[1] Univ Oeste Santa Catarina, Sch Dent, Dept Dent Mat & Operat Dent, UNOESC, BR-89600000 Joacaba, SC, Brazil
[2] Univ Luterana Brazil, ULBRA, Sch Dent, Dept Operat Dent, Canoas, RS, Brazil
关键词
clinical evaluation; composite resin; posterior tooth restoration; packable composite; 3-year clinical evaluation;
D O I
10.1111/j.1365-2842.2006.01539.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the clinical performance of four packable resin composite restorative materials in posterior teeth (Class I and II) compared with one hybrid composite after 3 years. Eighty-four restorations were placed in 16 patients. The tested materials were: (i) Solitaire + Solid Bond; (ii) ALERT + Bond-1; (iii) Surefil + Prime & Bond NT; (iv) Filtek P60 + Single Bond and (v) TPH Spectrum + Prime & Bond 2.1. All restorations were made using rubber dam isolation, and the cavity design was restricted to the elimination of carious tissue. Deeper cavities were covered with calcium hydroxide and/or glass-ionomer cement. Each adhesive system and composite resin was placed according to the manufacturer's instructions. One week later, the restorations were finished/polished and evaluated according USPHS modified criteria. Fourteen patients attended the 3-year recall and 75 restorations were evaluated at that time based on the same evaluation criteria. Friedman repeated measures analysis of variance by rank and Wilcoxon sign-ranked test for pair-wise comparison was used for data analysis (alpha = 0.05). The analysis was performed only for the baseline and for the 3-year period. Solitaire showed some fractures at marginal ridges in 25% of the cases. Solitaire and ALERT showed some concerns related to colour match (43 and 77%, respectively) and surface texture (86 and 77%, respectively). TPH Spectrum showed a great percentage of colour mismatch after 3 years, around 50%. Surefil and Filtek P60 showed an excellent clinical performance after 3 years, similar to the hybrid resin tested, TPH Spectrum. Solitaire did not fulfil the ADA acceptance criteria for restorative materials and, therefore, is not recommended for use in posterior restorations.
引用
收藏
页码:144 / 151
页数:8
相关论文
共 50 条
  • [21] CLINICAL-EVALUATION OF A POSTERIOR COMPOSITE (3-YEAR RESULTS)
    SETCOS, JC
    BASSIOUNY, MA
    BRUNSON, WD
    NORMAN, RD
    [J]. JOURNAL OF DENTAL RESEARCH, 1987, 66 : 129 - 129
  • [22] A 3-YEAR CLINICAL-EVALUATION OF COMPOSITE RESIN AND A HIGH COPPER AMALGAM IN POSTERIOR PRIMARY TEETH
    NELSON, GV
    OSBORNE, JW
    GALE, EN
    NORMAN, RD
    PHILLIPS, RW
    [J]. JOURNAL OF DENTISTRY FOR CHILDREN, 1980, 47 (06): : 414 - 418
  • [23] Ten-year Clinical Performance of Posterior Resin Composite Restorations
    Kraemer, Norbert
    Reinelt, Christian
    Frankenberger, Roland
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2015, 17 (05): : 433 - 441
  • [24] A VISIBLE LIGHT-CURED POSTERIOR COMPOSITE RESIN - RESULTS OF A 3-YEAR CLINICAL-EVALUATION
    BOKSMAN, L
    JORDAN, RE
    SUZUKI, M
    CHARLES, DH
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1986, 112 (05): : 627 - 631
  • [25] COMPOSITE VERSUS AMALGAM RESTORATIONS - A 3-YEAR EVALUATION
    HENDRIKS, FHJ
    LETZEL, H
    VRIJHOEF, MMA
    [J]. JOURNAL OF DENTAL RESEARCH, 1984, 63 : 231 - 231
  • [26] OBSERVATIONS ON A COMPOSITE RESIN FOR CLASS II RESTORATIONS - 3-YEAR REPORT
    PHILLIPS, RW
    AVERY, DR
    MEHRA, R
    SWARTZ, ML
    MCCUNE, RJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1973, 30 (06): : 891 - 897
  • [27] A 3-YEAR STUDY OF CLASS-I COMPOSITE RESIN RESTORATIONS
    SKEETERS, TM
    TIMMONS, JH
    RICHARDS, ND
    LASWELL, HR
    MITCHELL, RJ
    [J]. JOURNAL OF DENTAL RESEARCH, 1986, 65 : 303 - 303
  • [28] Two-year clinical evaluation of a packable resin-based composite
    Türkün, LS
    Türkün, M
    Özata, F
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2003, 134 (09): : 1205 - 1212
  • [29] CLINICAL-EVALUATION OF POSTERIOR COMPOSITE RESTORATIONS - 3 AND 4 YEAR RESULTS
    DERKSON, GD
    RICHARDSON, AS
    WALDMAN, R
    [J]. JOURNAL OF DENTAL RESEARCH, 1984, 63 : 174 - 174
  • [30] A 3-year retrospective study of clinical durability of bulk-filled resin composite restorations
    Ugurlu, Muhittin
    Sari, Fatmanur
    [J]. RESTORATIVE DENTISTRY AND ENDODONTICS, 2022, 47 (01):