Precision and performance characteristics of bisulfite conversion and real-time PCR (MethyLight) for quantitative DNA methylation analysis

被引:363
|
作者
Ogino, Shuji
Kawasaki, Takako
Brahmandam, Mohan
Cantor, Mami
Kirkner, Gregory J.
Spiegelman, Donna
Makrigiorgos, G. Mike
Weisenberger, Daniel J.
Laird, Peter W.
Loda, Massimo
Fuchs, Charles S.
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Pathol, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Dept Med, Boston, MA 02115 USA
[3] Brigham & Womens Hosp, Dept Radiat Oncol, Boston, MA 02115 USA
[4] Dana Farber Canc Inst, Dept Med Oncol, Boston, MA 02115 USA
[5] Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
[6] Harvard Univ, Sch Publ Hlth, Dept Epidemiol, Boston, MA 02115 USA
[7] Harvard Univ, Sch Publ Hlth, Dept Biostat, Boston, MA 02115 USA
[8] Univ So Calif, Norris Comprehens Canc Ctr, Keck Sch Med, Dept Surg, Los Angeles, CA USA
[9] Univ So Calif, Norris Comprehens Canc Ctr, Keck Sch Med, Dept Biochem & Mol Biol, Los Angeles, CA USA
来源
JOURNAL OF MOLECULAR DIAGNOSTICS | 2006年 / 8卷 / 02期
关键词
D O I
10.2353/jmoldx.2006.050135
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Assays to measure DNA methylation, which are important in epigenetic research and clinical diagnostics, typically rely on conversion of unmethylated. cytosine to uracil by sodium bisulfite. However, no study has comprehensively evaluated the precision and performance characteristics of sodium bisulfite conversion and subsequent quantitative methylation assay. We developed quantitative real-time polymerase chain reaction (MethyLight) to measure percentage of methylated reference (PMR, ie, degree of methylation) for the MGMT, MLH1, and CDKN2A (p16) promoters. To measure the precision of bisulfite conversion, we bisulfite-treated seven different aliquots of DNA from each of four paraffin-embedded colon cancer samples. To assess run-to-run variation, we repeated MethyLight five times. Bisulfite-to-bisulfite coefficient of variation (CV) of PMR ranged from 0.10 to 0.38 (mean, 0.21), and run-to-run CV of PMR ranged from 0.046 to 0.60 (mean, 0.31). Interclass correlation coefficients were 0.74 to 0.84 for the three loci, indicating good reproducibility. DNA mixing study with methylated and unmethylated. DNA showed good linearity of the assay. Of 272 colorectal cancers evaluated, most showed PMR either < 1 or > 10, and promoter methylation (PMR > 4) was tightly associated with loss of respective protein expression (P < 10(-16)). In conclusion, sodium bisulfite conversion and quantitative MethyLight assays have good precision and linearity and can be effectively used for high-throughput DNA methylation analysis on paraffin-embedded tissue.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 50 条
  • [1] Performance characteristics of bisulfite conversion and SYBR green based quantitative PCR for DNA methylation analysis
    Tewari, Shikha
    Bhatia, Vikram
    Goel, Madhu Mati
    Yadu, Alka
    Agarwal, Bhaskar
    Kumar, Sandeep
    Goel, Sudhir K.
    JOURNAL OF ENVIRONMENTAL BIOLOGY, 2013, 34 (04): : 667 - 671
  • [2] Bisulfite-Converted DNA Quantity Evaluation: A Multiplex Quantitative Real-Time PCR System for Evaluation of Bisulfite Conversion
    Hong, Sae Rom
    Shin, Kyoung-Jin
    FRONTIERS IN GENETICS, 2021, 12
  • [3] Gel-based Methylation Specific PCR and MethyLight® Real-Time Quantitative PCR for Assessing MGMT Promoter Methylation in Gliomas
    Talwalkar, S. S.
    Mantha, G.
    Murphy, J.
    Nikiforova, M. N.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2009, 11 (06): : 658 - 658
  • [4] DNA methylation analysis by digital bisulfite genomic sequencing and digital MethyLight
    Weisenberger, Daniel J.
    Trinh, Binh N.
    Campan, Mihaela
    Sharma, Shikhar
    Long, Tiffany I.
    Ananthnarayan, Suchitra
    Liang, Gangning
    Esteva, Francisco J.
    Hortobagyi, Gabriel N.
    McCormick, Frank
    Jones, Peter A.
    Laird, Peter W.
    NUCLEIC ACIDS RESEARCH, 2008, 36 (14) : 4689 - 4698
  • [5] Direct, real-time PCR (MethyLight) assay for methylation of O6-methylguanine-DNA methyltransferase promoter in glioma
    Chen Gong
    Wu Xing
    Yao Yu
    Zhou Liang-fu
    Mao Ying
    CHINESE MEDICAL JOURNAL, 2009, 122 (11) : 1342 - 1345
  • [6] Evaluation of a Quantitative DNA Methylation Analysis Technique Using Methylation-Sensitive/Dependent Restriction Enzymes and Real-Time PCR
    Oakes, Christopher C.
    La Salle, Sophie
    Robaire, Bernard
    Trasler, Jacquetta M.
    EPIGENETICS, 2006, 1 (03) : 146 - 152
  • [7] Accuracy of quantitative real-time PCR analysis
    D. G. Sochivko
    A. A. Fedorov
    D. A. Varlamov
    V. E. Kurochkin
    R. V. Petrov
    Doklady Biochemistry and Biophysics, 2013, 449 : 105 - 108
  • [8] Accuracy of quantitative real-time PCR analysis
    Sochivko, D. G.
    Fedorov, A. A.
    Varlamov, D. A.
    Kurochkin, V. E.
    Petrov, R. V.
    DOKLADY BIOCHEMISTRY AND BIOPHYSICS, 2013, 449 (01) : 105 - 108
  • [9] Real-time quantitative PCR
    Schmittgen, TD
    METHODS, 2001, 25 (04) : 383 - 385
  • [10] Detection of human cytomegalovirus DNA by real-time quantitative PCR
    Nitsche, A
    Steuer, N
    Schmidt, CA
    Landt, O
    Ellerbrok, H
    Pauli, G
    Siegert, W
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (07) : 2734 - 2737