Tool for inspecting faults from incorrectly cleaved fiber ends and contaminated optical fiber connector end surfaces

被引:7
|
作者
Kihara, Mitsuru [1 ]
Okada, Masaru [1 ]
Hosoda, Makoto [1 ]
Iwata, Tomoyuki [1 ]
Yajima, Yuichi [1 ]
Toyonaga, Masanobu [1 ]
机构
[1] Nippon Telegraph & Tel E Corp, Tech Assistance & Support Ctr, Ota Ku, Tokyo 1440053, Japan
关键词
Optical connector; Physical contact; Insertion loss; Return loss; Fiber cleaver; SPLICES;
D O I
10.1016/j.yofte.2012.07.004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We investigated and analyzed faults in field installable connection due to incorrectly cleaved fiber ends and manufactured physical contact (PC)-type connectors with contaminated end surfaces in optical access fiber networks. The insertion and return losses of fiber connections using incorrectly cleaved fiber ends might be at worst more than 40 dB and less than 30 dB, respectively. With PC-type connectors whose end surfaces are contaminated, the insertion and return losses might be at worst 8.7 and 27 dB, respectively. We developed an inspection tool for cleaved fiber ends and connector end surfaces as a countermeasure. The proposed tool has a simple structure and does not require focal adjustment. It can be used to inspect and clearly determine whether a fiber has been cleaved correctly and whether there is contamination or scratches on the connector end surfaces. The tool requires a slight increase of 11% in operation time compared to conventional fiber end preparation and assembly procedures. The proposed tool provides a simple and cost-effective way to inspect cleaved fiber ends and connector end surfaces and is suitable for field use. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:470 / 479
页数:10
相关论文
共 37 条
  • [11] Inspection technique for cleaved optical fiber ends based on Fabry-Perot resonator
    Kihara, Mitsuru
    Watanabe, Hiroshi
    Yajima, Yuichi
    Toyonaga, Masanobu
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [12] OPTICAL FIBER ENDOSCOPE TYPE OF-20E FOR INSPECTING INTERNAL SURFACES.
    Gerasimov, V.F.
    Ketkovich, A.A.
    1600, (14):
  • [13] OPTICAL FIBER ENDOSCOPE TYPE OD-20E FOR INSPECTING INTERNAL SURFACES
    GERASIMOV, VF
    KETKOVICH, AA
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1978, 14 (09): : 853 - 854
  • [14] Error analysis of geometry automatic measurement parameters of optical fiber connector end face
    Computer Science and Information Engineering Institute, Chongqing Technology and Business University, Chongqing 400067, China
    不详
    不详
    Zhongguo Jiguang, 2009, SUPPL. 2 (263-265):
  • [15] Fabrication of a V-groove on the optical fiber connector using a miniaturized machine tool
    Lee, JH
    Park, SR
    Yang, SH
    Kim, YS
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2004, 155 (1-3) : 1716 - 1722
  • [16] Automated Inspection of Defects in Optical Fiber Connector End Face Using Novel Morphology Approaches
    Mei, Shuang
    Wang, Yudan
    Wen, Guojun
    Hu, Yang
    SENSORS, 2018, 18 (05)
  • [17] Development and approbation of procedure for automated localization of fiber optic connector contaminated ferrule end face image artifacts
    Bourdine, Anton V.
    Pashin, Stanislav S.
    Giniatulina, Alina M.
    Vasilets, Alexander A.
    Antonov, Stanislav A.
    OPTICAL TECHNOLOGIES FOR TELECOMMUNICATIONS 2018, 2019, 11146
  • [18] Investigation Into the Influence of High-Power Optical Transmission on Fiber Withdrawal From Optical Connector
    Fukai, Chisato
    Abe, Yoshiteru
    Takaya, Masaaki
    Koyama, Ryo
    Katayama, Kazunori
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2020, 38 (18) : 5128 - 5135
  • [19] Lasing from semiconductor microring on the end of an optical fiber
    Corbett, B
    Lambkin, P
    Wu, GH
    Houlihan, J
    Huyet, G
    APPLIED PHYSICS LETTERS, 2002, 81 (05) : 808 - 810
  • [20] Deep Learning Based Automated Inspection of Weak Microscratches in Optical Fiber Connector End-Face
    Mei, Shuang
    Cai, Qi
    Gao, Zhijun
    Hu, Hao
    Wen, Guojun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70