Computed tomography implementation of multiple-image radiography

被引:58
|
作者
Brankov, JG [1 ]
Wernick, MN
Yang, YY
Li, J
Muehleman, C
Zhong, Z
Anastasio, MA
机构
[1] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
[2] IIT, Dept Biomed Engn, Chicago, IL 60616 USA
[3] Rush Univ, Ctr Med, Chicago, IL 60616 USA
[4] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11973 USA
关键词
Diffraction-enhanced imaging; Image reconstruction; Synchrotron radiation; X-ray phase-contrast imaging;
D O I
10.1118/1.2150788
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional x-ray computed tomography (CT) produces a single volumetric image that represents the spatially variant linear x-ray attenuation coefficient of an object. However, in many situations, differences in the x-ray attenuation properties of soft tissues are very small and difficult to measure in conventional x-ray imaging. In this work, we investigate an analyzer-based imaging method, called computed tomography multiple-image radiography (CT-MIR), which is a tomographic implementation of the recently proposed multiple-image radiography method. The CT-MIR method reconstructs concurrently three physical properties of the object. In addition to x-ray attenuation, CT-MIR produces volumetric images that represent the refraction and ultrasmall-angle scattering properties of the object. These three images can provide a rich description of the object's physical properties that are revealed by the probing x-ray beam. An imaging model for CT-MIR that is based on the x-ray transform of the object properties is established. The CT-MIR method is demonstrated by use of experimental data acquired at a synchroton radiation imaging beamline, and is compared to the pre-existing diffraction-enhanced imaging CT method. We also investigate the merit of an iterative reconstruction method for use with future clinical implementations of CT-MIR, which we anticipate would be photon limited. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:278 / 289
页数:12
相关论文
共 50 条
  • [21] THEORY OF MULTIPLE-IMAGE COMMUNICATION
    PERRIN, DG
    AV COMMUNICATION REVIEW, 1969, 17 (04) : 368 - 382
  • [22] LINEAR MULTIPLE-IMAGE STORAGE
    MUELLER, PF
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (11) : 1557 - &
  • [23] NONLINEAR MULTIPLE-IMAGE STORAGE
    MUELLER, PF
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1969, 59 (11) : 1535 - &
  • [24] An improved multiple-image radiography method extracting refraction information in analyzer-based imaging
    Wang, Yun-Bo
    Li, Gong-Ping
    Pan, Xiao-Dong
    Zheng, Sai-Chun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 770 : 182 - 188
  • [25] THE CONTRAST-DETAIL-DOSE EVALUATION OF IMAGE QUALITY, WITH APPLICATION TO COMPUTED RADIOGRAPHY, COMPUTED-TOMOGRAPHY, AND CONVENTIONAL RADIOGRAPHY
    COHEN, G
    AMTEY, SR
    WAGNER, LK
    KATRAGADDA, C
    FOGEL, S
    HANDEL, SF
    LESTER, RG
    DIBIANCA, FA
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 775 - 775
  • [26] Computed tomography vs. radiography image quality and appropriateness issues
    Bushong, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1297 - 1298
  • [27] Multiple-image hiding by information prechoosing
    Shi, Yishi
    Situ, Guohai
    Zhang, Jingjuan
    OPTICS LETTERS, 2008, 33 (06) : 542 - 544
  • [28] Multiple-image encryption by compressive holography
    Di, Hong
    Zheng, Kangfeng
    Zhang, Xin
    Lam, Edmund Y.
    Kim, Taegeun
    Kim, You Seok
    Poon, Ting-Chung
    Zhou, Changhe
    APPLIED OPTICS, 2012, 51 (07) : 1000 - 1009
  • [29] Characteristics of root fractures: Image on intraoral radiography, panoramic radiography, and cone-beam computed tomography
    Mizuhashi, Fumi
    Ogura, Ichiro
    Sugawara, Yoshihiro
    Oohashi, Makoto
    Sekiguchi, Hirokazu
    Saegusa, Hisato
    ORAL SCIENCE INTERNATIONAL, 2020, 17 (01) : 34 - 38
  • [30] A Variational Method for Multiple-Image Blending
    Wang, Wei
    Ng, Michael K.
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2012, 21 (04) : 1809 - 1822