Feasibility of precise and reliable glucose quantification in human whole blood samples by 1 tesla benchtop NMR

被引:4
|
作者
Stolz, Michael [1 ]
Schlawne, Carolin [2 ]
Hoffmann, Jens [2 ]
Hartmann, Vanessa [3 ,4 ,5 ]
Marini, Irene [1 ]
Fritsche, Andreas [3 ,4 ,5 ]
Peter, Andreas [3 ,4 ,6 ]
Bakchoul, Tamam [1 ]
Schick, Fritz [3 ,7 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Transfus Med, Tubingen, Germany
[2] Robert Bosch Power Tools GmbH, Leinfelden Echterdingen, Germany
[3] Univ Tubingen, Helmholtz Ctr Munich, Inst Diabet Res & Metab Dis, Tubingen, Germany
[4] German Ctr Diabet Res DZD eV, Tubingen, Germany
[5] Eberhard Karls Univ Tuebingen, Dept Internal Med, Div Endocrinol Diabetol Angiol Nephrol & Clin Che, Tubingen, Germany
[6] Univ Hosp Tuebingen, Dept Diagnost Lab Med, Inst Clin Chem & Pathobiochem, Tubingen, Germany
[7] Eberhard Karls Univ Tuebingen, Sect Expt Radiol, Dept Radiol, Tubingen, Germany
关键词
applications; body; diabetes; methods and engineering; MRS and MRSI methods; post-acquisition processing; quantitation; spectroscopic quantitation; SPECTROSCOPY; PLASMA; URINE; SERUM; INDICATOR; LEVEL; H-1;
D O I
10.1002/nbm.4358
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The standard procedure for blood glucose measurements is enzymatic testing. This method is cheap, but requires small samples of open blood with direct contact to the test medium. In principle, NMR provides non-contact analysis of body fluids, but high-field spectrometers are expensive and cannot be easily utilized under clinical conditions. Low-field NMR systems with permanent magnets are becoming increasingly smaller and more affordable. The studies presented here aim at exploring the capabilities of low-field NMR for measuring glucose concentrations in whole blood. For this purpose, a modern 1 T benchtop NMR spectrometer was used. Challenges arise from broad spectral lines, the glucose peak locations close to the water signal, low SNR and the interference with signals from other blood components. Whole blood as a sample comprises even more boundary conditions: crucial for reliable results are avoiding the separation of plasma and cells by gravitation and reliable reference values. First, the accuracy of glucose levels measured by NMR was tested using aqueous glucose solutions and commercially available bovine plasma. Then, 117 blood samples from oral glucose tolerance testing were measured with minimal preparation by simple pulse-acquire NMR experiments. The analysis itself is the key to achieve high precision, so several approaches were investigated: peak integration, orthogonal projection to latent structure analysis and support vector machine regression. Correlations between results from the NMR spectra and the routine laboratory automated analyzer revealed an RMSE of 7.90 mg/dL for the best model. 91.5% of the model output lies within the limits of the German Medical Association guidelines, which require the glucose measurement to be within 11% of the reference method. It is concluded that spectral quantification of glucose in whole blood samples by high-quality NMR spectrometers operating at 1 T is feasible with sufficient accuracy.
引用
下载
收藏
页数:11
相关论文
共 42 条
  • [41] Targeted 1H NMR metabolomics and immunological phenotyping of human fresh blood and serum samples discriminate between healthy individuals and inflammatory bowel disease patients treated with anti-TNF
    Notararigo, Sara
    Martin-Pastor, Manuel
    Roldan, Juan E. Vinuela
    Quiroga, Adriano
    Dominguez-Munoz, J. Enrique
    Acosta, Manuel Barreiro-de
    JOURNAL OF MOLECULAR MEDICINE-JMM, 2021, 99 (09): : 1251 - 1264
  • [42] Diagnostic implications of human cytomegalovirus immediate early-1 and pp67 mRNA detection in whole-blood samples from liver transplant patients using nucleic acid sequence-based amplification
    Blok, MJ
    Lautenschlager, I
    Goossens, VJ
    Middeldorp, JM
    Vink, C
    Höckerstedt, K
    Bruggeman, CA
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (12) : 4485 - 4491