Feasibility of precise and reliable glucose quantification in human whole blood samples by 1 tesla benchtop NMR

被引:4
|
作者
Stolz, Michael [1 ]
Schlawne, Carolin [2 ]
Hoffmann, Jens [2 ]
Hartmann, Vanessa [3 ,4 ,5 ]
Marini, Irene [1 ]
Fritsche, Andreas [3 ,4 ,5 ]
Peter, Andreas [3 ,4 ,6 ]
Bakchoul, Tamam [1 ]
Schick, Fritz [3 ,7 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Transfus Med, Tubingen, Germany
[2] Robert Bosch Power Tools GmbH, Leinfelden Echterdingen, Germany
[3] Univ Tubingen, Helmholtz Ctr Munich, Inst Diabet Res & Metab Dis, Tubingen, Germany
[4] German Ctr Diabet Res DZD eV, Tubingen, Germany
[5] Eberhard Karls Univ Tuebingen, Dept Internal Med, Div Endocrinol Diabetol Angiol Nephrol & Clin Che, Tubingen, Germany
[6] Univ Hosp Tuebingen, Dept Diagnost Lab Med, Inst Clin Chem & Pathobiochem, Tubingen, Germany
[7] Eberhard Karls Univ Tuebingen, Sect Expt Radiol, Dept Radiol, Tubingen, Germany
关键词
applications; body; diabetes; methods and engineering; MRS and MRSI methods; post-acquisition processing; quantitation; spectroscopic quantitation; SPECTROSCOPY; PLASMA; URINE; SERUM; INDICATOR; LEVEL; H-1;
D O I
10.1002/nbm.4358
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The standard procedure for blood glucose measurements is enzymatic testing. This method is cheap, but requires small samples of open blood with direct contact to the test medium. In principle, NMR provides non-contact analysis of body fluids, but high-field spectrometers are expensive and cannot be easily utilized under clinical conditions. Low-field NMR systems with permanent magnets are becoming increasingly smaller and more affordable. The studies presented here aim at exploring the capabilities of low-field NMR for measuring glucose concentrations in whole blood. For this purpose, a modern 1 T benchtop NMR spectrometer was used. Challenges arise from broad spectral lines, the glucose peak locations close to the water signal, low SNR and the interference with signals from other blood components. Whole blood as a sample comprises even more boundary conditions: crucial for reliable results are avoiding the separation of plasma and cells by gravitation and reliable reference values. First, the accuracy of glucose levels measured by NMR was tested using aqueous glucose solutions and commercially available bovine plasma. Then, 117 blood samples from oral glucose tolerance testing were measured with minimal preparation by simple pulse-acquire NMR experiments. The analysis itself is the key to achieve high precision, so several approaches were investigated: peak integration, orthogonal projection to latent structure analysis and support vector machine regression. Correlations between results from the NMR spectra and the routine laboratory automated analyzer revealed an RMSE of 7.90 mg/dL for the best model. 91.5% of the model output lies within the limits of the German Medical Association guidelines, which require the glucose measurement to be within 11% of the reference method. It is concluded that spectral quantification of glucose in whole blood samples by high-quality NMR spectrometers operating at 1 T is feasible with sufficient accuracy.
引用
下载
收藏
页数:11
相关论文
共 42 条
  • [1] STUDY ON MID-IR SPECTROSCOPY ON WHOLE BLOOD SAMPLES FOR HUMAN GLUCOSE QUANTIFICATION APPLICATIONS
    Romo-Cardenas, Gerardo S.
    de Dios Sanchez-Lopez, Juan
    Cosio-Leon, Maria
    Luque-Morales, Priscy
    Gomez, Claudia M.
    Nieto-Hipolito, Juan I.
    Jimenez-Cruz, Arturo
    Camacho-Lopez, Santiago
    Vazquez Briseno, Mabel
    INFRARED SENSORS, DEVICES, AND APPLICATIONS VIII, 2018, 10766
  • [2] Observation of resolved glucose signals in H-1 NMR spectra of the human brain at 4 Tesla
    Gruetter, R
    Garwood, M
    Ugurbil, K
    Seaquist, ER
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) : 1 - 6
  • [3] Tranexamic acid quantification in human whole blood using liquid samples or volumetric absorptive microsampling devices
    Lamy, Elodie
    Runge, Ileana
    Roberts, Ian
    Shakur-Still, Haleema
    Grassin-Delyle, Stanislas
    BIOANALYSIS, 2020, 12 (12) : 835 - 844
  • [4] Quantification of 1,3-butadiene induced DNA adducts in human blood samples
    Sangaraju, Dewakar
    Tretyakova, Natalia
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [5] Direct enzymatic assay for %HbA1c in human whole blood samples
    Liu, Limin
    Hood, Stefanie
    Wang, Yuping
    Bezverkov, Robert
    Dou, Chao
    Datta, Abhijit
    Yuan, Chong
    CLINICAL BIOCHEMISTRY, 2008, 41 (7-8) : 576 - 583
  • [6] Stability of human immunodeficiency virus type 1 proviral DNA in whole-blood samples
    Jennings, C
    Danilovic, A
    Scianna, S
    Brambilla, DJ
    Bremer, JW
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (08) : 4249 - 4250
  • [7] Capillary-driven distance-based paper analytical devices for albumin protein and glucose quantification in human whole blood
    Kawin Khachornsakkul
    Thithawat Trakoolwilaiwan
    Ruben Del-Rio-Ruiz
    Sameer Sonkusale
    Tapparath Leelasattarathkul
    Microchimica Acta, 2025, 192 (4)
  • [8] Identification and quantification of mepirapim and acetyl fentanyl in authentic human whole blood and urine samples by GC–MS/MS and LC–MS/MS
    Akira Mochizuki
    Hiroko Nakazawa
    Noboru Adachi
    Kenichi Takekawa
    Hideki Shojo
    Forensic Toxicology, 2018, 36 : 81 - 87
  • [9] Feasibility of detecting human immunodeficiency virus type 1 drug resistance in DNA extracted from whole blood or dried blood spots
    Steegen, Kim
    Luchters, Stanley
    Demecheleer, Els
    Dauwe, Kenny
    Mandaliya, Kishor
    Jaoko, Walter
    Plum, Jean
    Temmerman, Marleen
    Verhofstede, Chris
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (10) : 3342 - 3351
  • [10] Quality Control Methods for Optimal BCR-ABL1 Clinical Testing in Human Whole Blood Samples
    Stanoszek, Lauren M.
    Crawford, Erin L.
    Blomquist, Thomas M.
    Warns, Jessica A.
    Willey, Paige F. S.
    Willey, James C.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (03): : 391 - 400