Surface Temperature Measurement with Unknown Emissivity Using a Two-color Pyrometer Placed with a Reflector

被引:0
|
作者
Che, Xunjian [1 ]
Xie, Zhi [1 ]
机构
[1] Northeastern Univ, Dept Informat Sci & Technol, Shenyang, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
temperature measurement; emissivity; two-color; pyrometer; reflector;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An instrument for measuring surface temperature above 773 K has been developed. A gold-plated reflector is placed ahead of a two-color pyrometer. When the reflector is positioned facing the measured target, the received radiation is increased, and the difference between the effective emissivities of the two received wavelengths is shortened. As a result, the measurement error of the two-color pyrometer is reduced compared with the one without a reflector. The validation experiment has been conducted. The measurement uncertainty is evaluated, and the standard uncertainty is 4.0 K at 973 K.
引用
收藏
页码:214 / 217
页数:4
相关论文
共 50 条
  • [31] A fast fiber-optic two-color pyrometer for temperature measurements of metallic surfaces with varying emissivities
    Müller, B
    Renz, U
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 741 - 746
  • [32] Investigation of the Surface Temperature in Contact with Plasma by Two-Color Pyrometry
    Voronin, A. V.
    Goryainov, V. Yu.
    Kapralov, A. A.
    Tokarev, V. A.
    Sotnikova, G. Yu.
    TECHNICAL PHYSICS, 2023, 68 (12) : 799 - 805
  • [33] Investigation of the Surface Temperature in Contact with Plasma by Two-Color Pyrometry
    A. V. Voronin
    V. Yu. Goryainov
    A. A. Kapralov
    V. A. Tokarev
    G. Yu. Sotnikova
    Technical Physics, 2023, 68 : 799 - 805
  • [34] Two-color optical charge-coupled-device-based pyrometer using a two-peak filter
    Fu, Tairan
    Zhao, Huan
    Zeng, Jun
    Zhong, Maohua
    Shi, Congling
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (12):
  • [35] Study of the radiation emitted during the combustion of pyrotechnic charges. Part 1: Non stationary measurement of the temperature by means of a two-color pyrometer
    Gillard, P
    Roux, M
    PROPELLANTS EXPLOSIVES PYROTECHNICS, 2002, 27 (02) : 72 - 79
  • [36] Infrared Two-color Temperature Measurement System for AOD Bottom Lance
    Chen Gehua
    MATERIALS SCIENCE AND NANOTECHNOLOGY I, 2013, 531-532 : 765 - 768
  • [37] MULTISPECTRAL INFRARED PYROMETER FOR TEMPERATURE-MEASUREMENT WITH AUTOMATIC CORRECTION OF THE INFLUENCE OF EMISSIVITY
    TANK, V
    DIETL, H
    INFRARED PHYSICS, 1990, 30 (04): : 331 - 342
  • [38] A new wavelength selection criterion for two-color pyrometer interfered with participating media
    Huang, Yunwei
    Long, Mujun
    Chen, Dengfu
    Duan, Huamei
    Tan, Kai
    Gui, Lintao
    Liu, Tao
    INFRARED PHYSICS & TECHNOLOGY, 2018, 93 : 136 - 143
  • [39] Two-color pyrometer-based method for measuring temperature profiles and attenuation coefficients in a coal power plant
    Lukovic, Milentije
    Vicic, Milos
    Popovic, Zoran
    Zekovic, Ljubisa
    Kasalica, Becko
    Belca, Ivan
    COMBUSTION SCIENCE AND TECHNOLOGY, 2018, 190 (11) : 2018 - 2029
  • [40] Explosion temperature mapping of emulsion explosives containing TiH2 powders with the two-color pyrometer technique
    Yao, Yu-Le
    Cheng, Yang-Fan
    Zhang, Qi-Wei
    Xia, Yu
    Hu, Fang-Fang
    Wang, Quan
    Chen, Yuan
    DEFENCE TECHNOLOGY, 2022, 18 (10) : 1834 - 1841