共 50 条
Analysis of Radiation Exposure During Endovascular Aneurysm Repair
被引:0
|作者:
Butler, Michael
Patel, Madhukar S.
Wilson, Samuel E.
[1
]
机构:
[1] Univ Calif Irvine, Med Ctr, Dept Surg, Orange, CA 92868 USA
关键词:
ABDOMINAL AORTIC-ANEURYSM;
D O I:
暂无
中图分类号:
R61 [外科手术学];
学科分类号:
摘要:
Endovascular aneurysm repair (EVAR) is now the preferred procedure for abdominal aortic aneurysm repair. As a result of the need for fluoroscopy during EVAR, radiation exposure is a potential hazard. We studied the quantity of radiation delivered during EVAR to identify risks for excessive exposure. Fluoroscopy time, contrast volume used, and procedural details were recorded prospectively during EVARs. Using data collected from similar EVARs, an equation was derived to calculate approximate dose-area product (DAP) from fluoroscopy time. DAP values were then compared between procedures in which a relevant postdeployment procedure (PDP) was necessary intraoperatively with those without. Clinical data on 17 patients were collected. The mean age of patients was 68 (+/- 9) years. Fluoroscopy times and approximate DAP values were found to be significantly higher in the seven patients with a PDP compared with the 10 patients without an intraoperative PDP (31.2 [+/- 9.6] vs 22.7 [+/- 6.0] minutes, P = 0.033 and 537 [+/- 165] vs 390 [+/- 103] Gy.cm(2), P = 0.033, respectively). The average amount of contrast volume used was not significantly different between groups. Radiation emitted during EVARs with PDPs was significantly greater relative to those without PDPs. Device design and operators should thus aim to decrease PDPs and to minimize fluoroscopy time.
引用
收藏
页码:1029 / 1032
页数:4
相关论文