Thirty years of research on diagnostic and therapeutic thresholds for the self-measured blood pressure at home

被引:47
|
作者
Staessen, Jan A. [1 ,4 ]
Thijs, Lutgarde [4 ]
Ohkuboe, Takayoshi [5 ]
Kikuya, Masahiro [5 ]
Richart, Tom [4 ]
Boggia, Jose [4 ,6 ]
Adiyaman, Ahmet [3 ,4 ]
Dechering, Dirk G. [3 ,4 ]
Kuznetsova, Tatiana [4 ]
Thien, Theo [3 ]
de Leeuw, Peter [2 ]
Imai, Yutuka [5 ]
O'Brien, Eoin [7 ]
Parati, Gianfranco [8 ,9 ]
机构
[1] Maastricht Univ, Genet Epidemiol Unit, Dept Epidemiol, NL-6200 MD Maastricht, Netherlands
[2] Univ Hosp Maastricht, Dept Internal Med, Maastricht, Netherlands
[3] Radboud Univ Nijmegen, Nijmegen Med Ctr, Dept Gen Internal Med, NL-6525 ED Nijmegen, Netherlands
[4] Univ Louvain, Dept Cardiovasc Dis, Div Hypertens & Cardiovasc Rehabil, Studies Coordinating Ctr, Louvain, Belgium
[5] Tohoku Univ, Grad Sch Pharmaceut Sci & Med, Sendai, Miyagi 980, Japan
[6] Univ Republica, Hosp Clin, Dept Fisiopatol, Montevideo, Uruguay
[7] Univ Coll Dublin, Conway Inst Biomol & Biomed Res, Dublin 2, Ireland
[8] Univ Milan, Dept Clin Med & Prevent, Milan, Italy
[9] San Luca Hosp, Ist Auxol Italiano, Dept Cardiol, Milan, Italy
关键词
diagnostic threshold; home blood pressure; hypertension; normotension; reference frame; self-measured blood pressure;
D O I
10.1097/MBP.0b013e3283108f93
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective The goal of this review study is to summarize 30 years of research on cut-off limits for the self-measured blood pressure. Methods We reviewed two meta-analyses, several prospective outcome studies in populations and hypertensive patients, studies in pregnant women, three clinical trials and the thresholds proposed in earlier and current hypertension guidelines. Results In line with existing guidelines, prospective studies support that levels of the self-measured blood pressure at home of greater than or equal to 135 mmHg systolic or greater than or equal to 85 mmHg diastolic indicate hypertension. Circumstantial data suggest that levels of the self-measured blood pressure below 120/80 and 130/85 mmHg are optimal and normal, respectively. Therapeutic targets of the self-measured blood pressure to be attained on antihypertensive drug treatment are currently unknown, but should logically be lower (< 135/85 mmHg) than those used to diagnose hypertension. Currently, there is no proof that therapeutic thresholds for the home blood pressure should be lower in high-risk compared with normal-risk patients. A large body of evidence, however, demonstrated that each millimetre of mercury of blood pressure lowering counts in the prevention of cardiovascular complications and that in high-risk patients even small decreases in blood pressure result in large absolute benefit. Conclusion The thresholds to diagnose hypertension from self-measured blood pressure readings at home remain unaltered since the 2000 consensus conference, but are currently supported by outcome data. Further studies need to establish what values of the self-measured blood pressure are optimal and normal in terms of cardiovascular outcome. Blood Press Monit 13:352-365 (C) 2008 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:352 / 365
页数:14
相关论文
共 50 条
  • [1] Recent status of self-measured home blood pressure in the Japanese general population: a modern database on self-measured home blood pressure (MDAS)
    Kei Asayama
    Yasuharu Tabara
    Emi Oishi
    Satoko Sakata
    Takashi Hisamatsu
    Kayo Godai
    Mai Kabayama
    Yukako Tatsumi
    Jun Hata
    Masahiro Kikuya
    Kei Kamide
    Katsuyuki Miura
    Toshiharu Ninomiya
    Takayoshi Ohkubo
    Hypertension Research, 2020, 43 : 1403 - 1412
  • [2] Recent status of self-measured home blood pressure in the Japanese general population: a modern database on self-measured home blood pressure (MDAS)
    Asayama, Kei
    Tabara, Yasuharu
    Oishi, Emi
    Sakata, Satoko
    Hisamatsu, Takashi
    Godai, Kayo
    Kabayama, Mai
    Tatsumi, Yukako
    Hata, Jun
    Kikuya, Masahiro
    Kamide, Kei
    Miura, Katsuyuki
    Ninomiya, Toshiharu
    Ohkubo, Takayoshi
    HYPERTENSION RESEARCH, 2020, 43 (12) : 1403 - 1412
  • [3] Self-measured home blood pressure in predicting ambulatory hypertension
    Mansoor, GA
    White, WB
    AMERICAN JOURNAL OF HYPERTENSION, 2004, 17 (11) : 1017 - 1022
  • [4] Diagnostic threshold to define hypertension by self-measured home blood pressure - the clinical evidence.
    Den Hond, E
    Celis, H
    Fagard, RH
    O'Brien, ET
    Staessen, JA
    HYPERTENSION, 2004, 44 (04) : 576 - 576
  • [5] The utility of home blood pressure load in predicting average self-measured blood pressure
    Hinderliter, Alan L.
    Lin, Feng-Chang
    Yang, Yumei
    Viera, Laura A.
    Olsson, Emily
    Voora, Raven
    Viera, Anthony J.
    JOURNAL OF HYPERTENSION, 2024, 42 (09) : 1624 - 1631
  • [6] Comparison of clinic, home self-measured, and work self-measured blood pressures
    García-Vera, MP
    Labrador, FJ
    Sanz, J
    BEHAVIORAL MEDICINE, 1999, 25 (01) : 13 - 22
  • [7] Reliability of self-measured blood pressure for research purposes -: In reply
    Staessen, JA
    O'Brien, E
    ARCHIVES OF INTERNAL MEDICINE, 1999, 159 (19) : 2365 - 2366
  • [8] Comparison Of Automated Office Blood Pressure And Self-Measured Blood Pressure: Results From An Ongoing Self-Measured Blood Pressure Program
    Farahmand, Rosemary
    Cluett, Jennifer L.
    Barkowski, Laken
    Cohen, Marc L.
    Li, Jonathan X.
    Olowoyeye, Ruth
    Padwal, Raj
    Rakotz, Michael K.
    Russo, Elisabeth
    Sachdev, Neha
    Tighe, Katherine M.
    Tsipas, Stavros
    Walley, Hannah
    Wood, Peter S.
    Wozniak, Gregory
    Juraschek, Stephen P.
    HYPERTENSION, 2023, 80
  • [9] Practical aspect of monitoring hypertension based on self-measured blood pressure at home
    Imai, Y
    Ohkubo, T
    Kikuya, M
    Hashimoto, J
    INTERNAL MEDICINE, 2004, 43 (09) : 771 - 778
  • [10] Poor reliability of self-measured home blood pressure reported by logbook.
    Okubo, Katsuaki
    Kushiro, Tosio
    Asai, Takae
    Ichiyama, Izumi
    Takahashi, Atsuhiko
    Saito, Fumio
    Otsuka, Yuji
    JOURNAL OF HYPERTENSION, 2006, 24 : 87 - 87