A biomechanical comparison of four different cementless press-fit stems used in revision surgery for total knee replacements

被引:0
|
作者
Zdero, Radovan [1 ,2 ]
Saidi, Kevan [3 ]
Mason, Stephanie A. [1 ]
Schemitsch, Emil H. [4 ]
Naudie, Douglas D. R. [5 ]
机构
[1] St Michaels Hosp, Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[3] Sudbury Reg Hosp, Sudbury, ON, Canada
[4] Univ Toronto, Fac Med, Dept Surg, Toronto, ON M5S 1A1, Canada
[5] Univ Western Ontario, Univ Hosp, London Hlth Sci Ctr, London, ON N6A 5A5, Canada
关键词
Biomechanics; press-fit stems; revision surgery; total knee replacement; FINITE-ELEMENT-ANALYSIS; TOTAL HIP IMPLANT; FRACTURE FIXATION; TIBIAL COMPONENT; SYNTHETIC FEMURS; FEMORAL STEMS; IN-VITRO; ARTHROPLASTY; DESIGN; STABILITY;
D O I
10.1177/0954411912453246
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Few biomechanical studies exist on femoral cementless press-fit stems for revision total knee replacement (TKR) surgeries. The aim of this study was to compare the mechanical quality of the femur-stem interface for a series of commercially available press-fit stems, because this interface may be a 'weak link' which could fail earlier than the femur-TKR bond itself. Also, the femur-stem interface may become particularly critical if distal femur bone degeneration, which may necessitate or follow revision TKR, ever weakens the femur-TKR bond itself. The authors implanted five synthetic femurs each with a Sigma Short Stem (SSS), Sigma Long Stem (SLS), Genesis II Short Stem (GSS), or Genesis II Long Stem (GLS). Axial stiffness, lateral stiffness, 'offset load' torsional stiffness, and 'offset load' torsional strength were measured with a mechanical testing system using displacement control. Axial (range = 1047-1461 N/mm, p = 0.106), lateral (range = 415-462N/mm, p = 0.297), and torsional (range = 115-139 N/mm, p > 0.055) stiffnesses were not different between groups. The SSS had higher torsional strength (863 N) than the other stems (range = 167-197 N, p < 0.001). Torsional failure occurred by femoral 'spin' around the stem's long axis. There was poor linear correlation between the femur-stem interface area versus axial stiffness (R = 0.38) and torsional stiffness (R = 0.38), and there was a moderate linear correlation versus torsional strength (R = 0.55). Yet, there was a high inverse linear correlation between interfacial surface area versus lateral stiffness (R = 0.79), although this did not result in a statistical difference between stem groups (p = 0.297). These press-fit stems provide equivalent stability, except that the SSS has greater torsional strength.
引用
收藏
页码:848 / 857
页数:10
相关论文
共 32 条
  • [21] A comparison between cemented, press-fit, and HA-coated interfaces in Kinemax total knee replacement
    Walker, PS
    Sathasivam, S
    Cobb, A
    Learmonth, ID
    Grobler, GP
    Pinder, IM
    Marchetti, N
    Spinelli, MD
    Welsby, A
    KNEE, 2000, 7 (02): : 71 - 78
  • [22] Changes in bone mineral density of the distal femur after revision total knee arthroplasty with metaphyseal press-fit stem
    Jensen C.L.
    Petersen M.M.
    Schrøder H.M.
    Lund B.
    Journal of Orthopaedics and Traumatology, 2010, 11 (3) : 143 - 148
  • [23] A randomised, controlled trial of cemented versus cementless press-fit condylar total knee replacement -: Ten-year survival analysis
    Khaw, FM
    Kirk, LMG
    Morris, RW
    Gregg, PJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05): : 658 - 666
  • [24] Comparative Biomechanical In Vitro Study of Different Modular Total Knee Arthroplasty Revision Stems With Bone Defects
    Guttowski, Dario
    Polster, Valerie
    Huber, Gerd
    Morlock, Michael M.
    Pueschel, Klaus
    Nuechtern, Jakob
    JOURNAL OF ARTHROPLASTY, 2020, 35 (11): : 3318 - 3325
  • [25] Intra-Operative Periprosthetic Fractures Associated With Press Fit Stems in Revision Total Knee Arthroplasty Incidence, Management, and Outcomes
    Cipriano, Cara A.
    Brown, Nicholas M.
    Della Valle, Craig J.
    Moric, Mario
    Sporer, Scott M.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 1310 - 1313
  • [26] Alignment and Fixation in Revision Total Knee Arthroplasty With Press-Fit, Offset, Diaphyseal-Engaging Stem Extensions, and Eccentric Reaming Technique
    Vince, Kelly G.
    Hoskins, Wayne T.
    English, Michael
    JOURNAL OF ARTHROPLASTY, 2023, 38 (06): : S302 - S307
  • [27] The press-fit condylar modular total knee system - Four-to-six-year results with a posterior-cruciate-substituting design
    Ranawat, CS
    Luessenhop, CP
    Rodriguez, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (03): : 342 - 348
  • [28] In vivo comparison of femorotibial contact positions for press-fit posterior stabilized and posterior cruciate-retaining total knee arthroplasties
    Komistek, RD
    Scott, RD
    Dennis, DA
    Yasgur, D
    Anderson, DT
    Hajner, ME
    JOURNAL OF ARTHROPLASTY, 2002, 17 (02): : 209 - 216
  • [29] Comparable Stability of Cemented vs Press-Fit Placed Stems in Revision Total Knee Arthroplasty With Mild to Moderate Bone Loss: 6.5-Year Results From a Randomized Controlled Trial With Radiostereometric Analysis
    Kosse, Nienke M.
    van Hellemondt, Gijs G.
    Wymenga, Ate B.
    Heesterbeek, Petra J. C.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01): : 197 - 201
  • [30] Biomechanical evaluation of tibial bone adaptation after revision total knee arthroplasty: A comparison of different implant systems
    Paz Quilez, Maria
    Seral, Belen
    Angeles Perez, Maria
    PLOS ONE, 2017, 12 (09):