A biomechanical comparison of four different cementless press-fit stems used in revision surgery for total knee replacements

被引:0
|
作者
Zdero, Radovan [1 ,2 ]
Saidi, Kevan [3 ]
Mason, Stephanie A. [1 ]
Schemitsch, Emil H. [4 ]
Naudie, Douglas D. R. [5 ]
机构
[1] St Michaels Hosp, Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[3] Sudbury Reg Hosp, Sudbury, ON, Canada
[4] Univ Toronto, Fac Med, Dept Surg, Toronto, ON M5S 1A1, Canada
[5] Univ Western Ontario, Univ Hosp, London Hlth Sci Ctr, London, ON N6A 5A5, Canada
关键词
Biomechanics; press-fit stems; revision surgery; total knee replacement; FINITE-ELEMENT-ANALYSIS; TOTAL HIP IMPLANT; FRACTURE FIXATION; TIBIAL COMPONENT; SYNTHETIC FEMURS; FEMORAL STEMS; IN-VITRO; ARTHROPLASTY; DESIGN; STABILITY;
D O I
10.1177/0954411912453246
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Few biomechanical studies exist on femoral cementless press-fit stems for revision total knee replacement (TKR) surgeries. The aim of this study was to compare the mechanical quality of the femur-stem interface for a series of commercially available press-fit stems, because this interface may be a 'weak link' which could fail earlier than the femur-TKR bond itself. Also, the femur-stem interface may become particularly critical if distal femur bone degeneration, which may necessitate or follow revision TKR, ever weakens the femur-TKR bond itself. The authors implanted five synthetic femurs each with a Sigma Short Stem (SSS), Sigma Long Stem (SLS), Genesis II Short Stem (GSS), or Genesis II Long Stem (GLS). Axial stiffness, lateral stiffness, 'offset load' torsional stiffness, and 'offset load' torsional strength were measured with a mechanical testing system using displacement control. Axial (range = 1047-1461 N/mm, p = 0.106), lateral (range = 415-462N/mm, p = 0.297), and torsional (range = 115-139 N/mm, p > 0.055) stiffnesses were not different between groups. The SSS had higher torsional strength (863 N) than the other stems (range = 167-197 N, p < 0.001). Torsional failure occurred by femoral 'spin' around the stem's long axis. There was poor linear correlation between the femur-stem interface area versus axial stiffness (R = 0.38) and torsional stiffness (R = 0.38), and there was a moderate linear correlation versus torsional strength (R = 0.55). Yet, there was a high inverse linear correlation between interfacial surface area versus lateral stiffness (R = 0.79), although this did not result in a statistical difference between stem groups (p = 0.297). These press-fit stems provide equivalent stability, except that the SSS has greater torsional strength.
引用
收藏
页码:848 / 857
页数:10
相关论文
共 32 条
  • [1] RESULTS OF REVISION TOTAL KNEE ARTHROPLASTY USING PRESS-FIT CEMENTLESS STEM
    Iamaguchi, Maurcio Masasi
    Vicente de Castro Filho, Fernando Bley
    Gobbi, Riccardo Gomes
    Passarelli Tirico, Luis Eduardo
    Pecora, Jose Ricardo
    Camanho, Gilberto Luis
    ACTA ORTOPEDICA BRASILEIRA, 2013, 21 (01): : 23 - 26
  • [2] Results of Press-fit Stems in Revision Knee Arthroplasties
    Wood, Gavin C.
    Naudie, Douglas D. R.
    MacDonald, Steven J.
    McCalden, Richard W.
    Bourne, Robert B.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (03) : 810 - 817
  • [3] Global fit concept in revision hip arthroplasty for cementless press-fit femoral stems
    Canovas, F.
    LeBeguec, P.
    Batard, J.
    Gaillard, F.
    Dagneaux, L.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (04) : 579 - 581
  • [4] Cementless revision femoral stems application of press-fit principles and clinical outcomes
    François Canovas
    Sophie Putman
    Louis Dagneaux
    Lamine Chadli
    Pierre Le Béguec
    International Orthopaedics, 2019, 43 : 2261 - 2267
  • [5] Cementless revision femoral stems application of press-fit principles and clinical outcomes
    Canovas, Francois
    Putman, Sophie
    Dagneaux, Louis
    Chadli, Lamine
    Le Beguec, Pierre
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (10) : 2261 - 2267
  • [6] Component Alignment in Revision Total Knee Arthroplasty Using Diaphyseal Engaging Modular Offset Press-Fit Stems
    Nakasone, Cass K.
    Abdeen, Ayesha
    Khachatourians, Armond G.
    Sugimori, Tanzo
    Vince, Kelly G.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (08): : 1178 - 1181
  • [7] Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements
    Fehring, TK
    Murphy, JA
    Hayes, TD
    Roberts, DW
    Pomeroy, DL
    Griffin, WL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) : 40 - 50
  • [8] The long-term results of press-fit cemented stems in total knee prostheses
    Langlais, F.
    Belot, N.
    Ropars, M.
    Lambotte, J. C.
    Thomazeau, H.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (08): : 1022 - 1026
  • [9] A randomised controlled trial of cemented versus cementless press-fit condylar total knee replacement
    Baker, P. N.
    Khaw, F. M.
    Kirk, L. M. G.
    Esler, C. N. A.
    Gregg, P. J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (12): : 1608 - 1614
  • [10] Biomechanical comparison of two surgical techniques for press-fit reconstruction of the posterolateral complex of the knee
    Panzica, Martin
    Janzik, Janne
    Bobrowitsch, Evgenij
    Krettek, Christian
    Hawi, Nael
    Hurschler, Christof
    Jagodzinski, Michael
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (11) : 1579 - 1588