A Self-Sensing Stator-Current-Based Control System of a DFIG Connected to a DC-Link

被引:35
|
作者
Marques, G. D. [1 ]
Iacchetti, Matteo F. [2 ]
机构
[1] Univ Lisbon, INESC ID, Inst Super Tecn, P-1049001 Lisbon, Portugal
[2] Univ Manchester, Sch Elect & Elect Engn, Manchester M60 1QD, Lancs, England
关键词
DC-link; doubly fed induction generator (DFIG); induction generator; self-sensing technique; FED INDUCTION GENERATOR; SENSORLESS CONTROL; POWER; OPERATION; MICROGRIDS;
D O I
10.1109/TIE.2015.2426675
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a self-sensing technique for the field-oriented control and frequency regulation of a doubly fed induction generator connected to a dc-link. In this system, the stator circuits are connected to a dc-link through a diode bridge and the rotor circuits are controlled by a voltage source inverter connected to the same dc-link. As the diode bridge maintains the fundamental harmonics of the stator current and voltage approximately in phase, an almost zero average d-axis stator current results in the stator flux reference frame. This property is used to estimate the slip angle, required to implement the field orientation in the self-sensing technique in loaded conditions. At no load the system is controlled using a different methodology. The analysis and synthesis of the control chains are presented by analytic relations. The sensitivity study shows that the method exhibits reduced sensitivity to the parameter mismatch, resulting in a small orientation error. Experimental results confirm the good performance of the proposed method.
引用
收藏
页码:6140 / 6150
页数:11
相关论文
共 50 条
  • [21] Direct Resonant Control Strategy for Torque Ripple Mitigation of DFIG Connected to DC Link through Diode Rectifier on Stator
    Nian, Heng
    Wu, Chao
    Cheng, Peng
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (09) : 6936 - 6945
  • [22] Design of Common DC-Link Capacitor in Multiple-Drive System Based on Reduced DC-Link Current Harmonics Modulation
    Baburajan, Silpa
    Wang, Haoran
    Mandrile, Fabio
    Yao, Bo
    Wang, Qian
    Kumar, Dinesh
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (08) : 9703 - 9717
  • [23] Inner Control Method and Frequency Regulation of a DFIG Connected to a DC Link
    Marques, G. D.
    Iacchetti, Matteo F.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2014, 29 (02) : 435 - 444
  • [24] Improving the DC-Link Voltage of DFIG Driven Wind System Using Modified Sliding Mode Control
    Hiremath R.
    Moger T.
    [J]. Distributed Generation and Alternative Energy Journal, 2023, 38 (03): : 715 - 742
  • [25] A Sensorless Flux Oriented Control Scheme for a DFIG Connected to a DC Link
    Li, Jia
    Corzine, Keith
    [J]. 2015 CLEMSON UNIVERSITY POWER SYSTEMS CONFERENCE (PSC), 2015,
  • [26] Discrete-Time DC-Link Voltage and Current Control of a Grid-Connected Inverter with LCL-Filter and Very Small DC-Link Capacitance
    Kalmbach, Oliver
    Dirscherl, Christian
    Hackl, Christoph M.
    [J]. ENERGIES, 2020, 13 (21)
  • [27] A Simplified Stator Frequency and Power Control Method of DFIG-DC System Without Stator Voltage and Current Sensors
    Wu, Chao
    Jiao, Yingzong
    Nian, Heng
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (06) : 5562 - 5566
  • [28] Stability of DC-Link Voltage Affected by Phase-Locked Loop for DFIG-Based Wind Turbine Connected to a Weak AC System
    Wang, Dong
    Hu, Jiabing
    Huang, Yunhui
    Wang, Ningbo
    Zhou, Qiang
    [J]. 2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 2600 - 2606
  • [29] Air-Gap Power-Based Sensorless Control in a DFIG Connected to a DC Link
    Marques, G. D.
    Sousa, Duarte M.
    Iacchetti, Matteo F.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (01) : 367 - 375
  • [30] An Improved DC-Link Voltage Control Strategy for Grid Connected Converters
    Merai, Meriem
    Naouar, Mohamed Wissem
    Slama-Belkhodja, Ilhem