The endotracheal tube air leak test does not predict extubation outcome in critically ill pediatric patients

被引:50
|
作者
Wratney, Angela T. [1 ]
Benjamin, Daniel Kelly, Jr. [2 ,3 ]
Slonim, Anthony D. [4 ,5 ,6 ,7 ]
He, James [8 ]
Hamel, Donna S.
Cheifetz, Ira M. [9 ]
机构
[1] George Washington Univ, Childrens Natl Med Ctr, Washington, DC 20052 USA
[2] Duke Univ Pediat, Durham, NC 27705 USA
[3] Duke Clin Res Int, Res Fellowship Program, Durham, NC USA
[4] Carilion Med Ctr, Roanoke, VA 24014 USA
[5] Carilion Clin, Dept Med, Roanoke, VA 24014 USA
[6] Carilion Clin, Dept Pediat, Roanoke, VA 24014 USA
[7] Univ Virginia, Sch Med, Roanoke, VA USA
[8] Childrens Natl Med Ctr, Mclean, VA USA
[9] Duke Univ, Duke Childrens Hosp, Pediat Intens Care Unit, Med Ctr, Durham, NC USA
关键词
air leak test; cuff leak test; predictor variables; extubation; mechanical ventilation; endotracheal tube leak; respiratory failure; pediatric; neonate; stridor; noninvasive ventilation;
D O I
10.1097/PCC.0b013e3181849901
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Endotracheal tube air leak pressures are used to predict postextubation upper airway compromise such as stridor, upper airway obstruction, or risk of reintubation. To determine whether the absence of an endotracheal tube air leak (air leak test >= 30 cm H2O) measured during the course of mechanical ventilation predicts extubation failure in infants and children. Design: Prospective, blinded cohort. Setting: Multidisciplinary pediatric intensive care unit of a university hospital. Patients: Patients younger than or equal to 18 yrs and intubated >= 24 hrs. Interventions: The pressure required to produce an audible endotracheal tube air leak was measured within 12 hrs of intubation and extubation. Unless prescribed by the medical care team, patients did not receive neuromuscular blocking agents during air leak test measurements. Measurements and Main Results: The need for reintubation (i.e., extubation failure) was recorded during the 24-hr postextubation period. Seventy-four patients were enrolled resulting in 59 observed extubation trials. The extubation failure rate was 15.3% (9 of 59). Seven patients were treated for postextubation stridor. Extubation failure was associated with a longer median length of ventilation, 177 vs. 78 hrs, p = 0.03. Extubation success was associated with the use of postextubation noninvasive ventilation (p = 0.04). The air leak was absent for the duration of mechanical ventilation (i.e., >= 30 cm H2O at intubation and extubation) in ten patients. Absence of the air leak did not predict extubation failure (negative predictive value 27%, 95% confidence interval 6-60). The air leak test was >= 30 cm H2O before extubation in 47% (28 of 59) of patients yet 23 patients extubated successfully (negative predictive value 18%). Conclusions: An endotracheal tube air leak pressure >= 30 cm H2O measured in the nonparalyzed patient before extubation or for the duration of mechanical ventilation was common and did not predict an increased risk for extubation failure. Pediatric patients who are clinically identified as candidates for an extubation trial but do not have an endotracheal tube air leak may successfully tolerate removal of the endotracheal tube. (Pediatr Crit Care Med 2008; 9:490-496)
引用
收藏
页码:490 / 496
页数:7
相关论文
共 50 条
  • [21] Can we predict outcome in critically ill elderly patients?
    Govil, Deepak
    Pal, Divya
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2021, 25 (06) : 615 - 616
  • [22] Simple motor tasks independently predict extubation failure in critically ill neurological patients
    Kutchak, Fernanda Machado
    Rieder, Marcelo de Mello
    Victorino, Josue Almeida
    Meneguzzi, Carla
    Poersch, Karla
    Forgiarini Junior, Luiz Alberto
    Bianchin, Marino Muxfeldt
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2017, 43 (03) : 183 - 189
  • [23] Using the Synergy Model as Best Practice in Endotracheal Tube Suctioning of Critically Ill Patients
    Kuriakose, Ancy
    DIMENSIONS OF CRITICAL CARE NURSING, 2008, 27 (01) : 10 - 15
  • [24] Association Between Endotracheal Tube Size and Outcomes in Critically Ill Patients-Reply
    Casey, Jonathan D.
    Campbell, Benjamin R.
    Gelbard, Alexander
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2023, 149 (04) : 378 - 379
  • [25] Unplanned extubation in pediatric critically ill patients: A systematic review and best practice recommendations
    Lucas da Silva, Paulo Sergio
    de Carvalho, Werther Brunow
    PEDIATRIC CRITICAL CARE MEDICINE, 2010, 11 (02) : 287 - 294
  • [26] The "air leak" test around the endotracheal tube, as a predictor of postextubation stridor, is age dependent in children
    Mhanna, MJ
    Zamel, YB
    Tichy, CM
    Super, DM
    CRITICAL CARE MEDICINE, 2002, 30 (12) : 2639 - 2643
  • [27] Prediction of extubation outcome in critically ill patients: a systematic review and meta-analysis
    Torrini, Flavia
    Gendreau, Segolene
    Morel, Johanna
    Carteaux, Guillaume
    Thille, Arnaud W.
    Antonelli, Massimo
    Dessap, Armand Mekontso
    CRITICAL CARE, 2021, 25 (01)
  • [28] Inspiratory pressure maximal inspiratory pressure: Does it predict successful extubation in critically ill infants and children?
    ElKhatib, MF
    Baumeister, B
    Smith, PG
    Chatburn, RL
    Blumer, JL
    INTENSIVE CARE MEDICINE, 1996, 22 (03) : 264 - 268
  • [29] Prediction of extubation outcome in critically ill patients: a systematic review and meta-analysis
    Flavia Torrini
    Ségolène Gendreau
    Johanna Morel
    Guillaume Carteaux
    Arnaud W. Thille
    Massimo Antonelli
    Armand Mekontso Dessap
    Critical Care, 25
  • [30] Does the acquisition of MRSA affect outcome of critically ill patients?
    Powell, CG
    Macnaughton, PD
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (05) : 795P - 795P