Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system

被引:58
|
作者
Bryant, J. A. [1 ]
Drage, N. A. [1 ]
Richmond, S. [1 ]
机构
[1] Univ Dent Hosp, Cardiff, S Glam, Wales
关键词
dental; cone beam computed tomography; imaging techniques; radiographic phantoms;
D O I
10.1259/dmfr/13227258
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: As part of an ongoing programme to improve diagnosis and treatment planning relevant to implant placement, orthodontic treatment and dentomaxillofacial surgery, a study has been made of the spatial accuracy and density response of an i-CAT, a cone beam CT (CBCT) dental imaging System Supplied by Imaging Sciences International Inc. Methods: Custom-made phantoms Using acrylic Sheet and water Were used for measurements oil spatial accuracy, density response and noise. The Measurements were made over a period of several months oil a clinical machine rather than oil a machine dedicated to research. Results: Measurements on a precision grid showed the spatial accuracy to be Universally within the tolerance of +/- 1 pixel. The density response and the noise in the data were found to depend strongly on the mass in the slice being scanned. Conclusions: The density response Was Subject to two effects. The first effect changes the whole slice uniformly and linearly depends oil the total mass in the slice. The second effect exists when there is mass Outside the Field of view, dubbed the "exo-mass" effect. This effect lowers the measured CT number rapidly at the scan edge furthest from the exo-mass and raises it on the adjacent edge. The noise also depended quasi-linearly oil the mass in the slice. Some general performance rules were drafted to describe these effects and a preliminary correction algorithm was constructed.
引用
收藏
页码:365 / 374
页数:10
相关论文
共 50 条
  • [1] Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography
    Ludlow, John B.
    Walker, Cameron
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (06) : 802 - 817
  • [2] Validation of a windowing protocol for accurate in vivo tooth segmentation using i-CAT cone beam computed tomography
    Rastegar, Babak
    Thumilaire, Brice
    Odri, Guillaume A.
    Siciliano, Sergio
    Zapala, Jan
    Mahy, Pierre
    Olszewski, Raphael
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 27 (07): : 1001 - 1008
  • [3] Implant imaging with the I-CAT® cone-beam CT -: a progress report
    Brooks, SL
    Beason, RC
    Sarment, D
    Sukovic, P
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1184 - 1186
  • [4] Superimposition of a cone beam computed tomography (CBCT) scan and a photograph: A dental technique
    Lee, Soo Young
    Kim, Heechul
    Lee, Doyun
    Park, Chan
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 212 - 215
  • [5] Absorbed dose model to scan parameters in dental cone beam computed tomography
    Jia, Shumei
    Guo, Xiaoyue
    Xing, Yuxiang
    Zhang, Li
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [6] Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions
    Jiang, Tingting
    Lee, Sang-Mi
    Hou, Yanan
    Chang, Xin
    Hwang, Hyeon-Shik
    KOREAN JOURNAL OF ORTHODONTICS, 2016, 46 (03) : 129 - 136
  • [7] Cone Beam Computed Tomography Imaging in Dental Implants: A Primer for Clinical Radiologists
    Bernaerts, Anja
    Barbier, Lieven
    Abeloos, Johan
    De Backer, Tom
    Bosmans, Frederik
    Vanhoenacker, Filip M.
    Casselman, Jan
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2020, 24 (05) : 499 - 509
  • [8] Avoiding Radiation Risks from Dental Cone-beam Computed Tomography Imaging in Orthodontic Patients
    Nouh, Abdallah S.
    Majeed, Abdel H. M.
    Selim, Essam Mohamed Nassef
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2022, 55 (01): : 108 - 115
  • [9] Quality control of a kV cone beam computed tomography imaging system
    Marguet, M.
    Bodez, V.
    CANCER RADIOTHERAPIE, 2009, 13 (05): : 345 - 352
  • [10] Beam alignment and image distortion assessment of dental cone beam computed tomography (CBCT) system
    Rabba, J. A.
    Jaafar, H. A.
    Jafri, M. Z. M.
    Suhaimi, F. M.
    Osman, N. D.
    11TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS (ISMP) 2019, 2020, 1497