Determination of nanomolar concentrations of phosphate in freshwaters using flow injection with luminol chemiluminescence detection

被引:78
|
作者
Yaqoob, M
Nabi, A
Worsfold, PJ
机构
[1] Univ Plymouth, Sch Earth Ocean & Environm Sci, Plymouth PL4 8AA, Devon, England
[2] Univ Plymouth, Plymouth Environm Res Ctr, Plymouth PL4 8AA, Devon, England
[3] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
chemilummescence; flow injection analysis; phosphate; heteropoly acid; freshwaters;
D O I
10.1016/j.aca.2003.12.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid flow injection (FI) method is reported for the determination of phosphate (as molybdate reactive P) in freshwaters based on luminol chemiluminescence (CL) detection. The molybdophosphoric heteropoly acid formed by phosphate and ammonium molybdate in acidic conditions generated chemiluminescence emission via the oxidation of luminol. The detection limit (3 x standard deviation of blank) was 0.03 mug P l(-1) (1.0 nM), with a sample throughput of 180 h(-1). The calibration graph was linear over the range 0.032-3.26 mug P l(-1) (r(2) = 0.9880) with relative standard deviations (n = 4) in the range 1.2-4.7%. Interfering cations (Ca(II), Mg(II), Ni(II), Zn(II), Cu(II), Co(II), Fe(II) and Fe(III)) were removed by passing the sample through an in-line iminodiacetate chelating column. Silicate interference (at 5 mg Si l(-1)) was effectively masked by the addition of tartaric acid and other common anions (Cl(-), SO(4)(2-), HCO(3)(-), NO(3)(-) and NO(2)(-)) did not interfere at their maximum admissible concentrations in freshwaters. The method was applied to freshwater samples and the results (26.1 +/- 1.1-62.0 +/- 0.4 mug P l(-1)) were not significantly different (P = 0.05) from results obtained using a segmented flow analyser method with spectrophotometric detection (24.4 +/- 4.45-84.0 +/- 16.0 mug P l(-1)). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [21] Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Tomás, V
    Martín, J
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (01) : 189 - 194
  • [22] Flow Injection Chemiluminescence Determination of Paraquat using Luminol and Ag(III) Complex
    Liu, Fei
    Shi, Hongmei
    Xu, Xiangdong
    Kang, Weijun
    Li, Zhanhua
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (02) : 795 - 798
  • [23] Determination of methyltestosterone using flow injection with chemiluminescence detection
    Xie, ZH
    Ouyang, XQ
    Guo, LQ
    Lin, XC
    Chen, GN
    [J]. LUMINESCENCE, 2005, 20 (03) : 231 - 235
  • [24] Flow-Injection Determination of Ornidazole by Chemiluminescence Detection Basedon a Luminol-Ferricyanide Reaction
    Yi Lv
    Zhujun Zhang
    Deyong He
    Yufei Hu
    [J]. Analytical Sciences, 2003, 19 : 625 - 626
  • [25] Flow-injection determination of cysteine in pharmaceuticals based on luminol-persulphate chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    [J]. LUMINESCENCE, 2008, 23 (03) : 144 - 149
  • [26] Flow-injection determination of ornidazole by chemiluminescence detection based on a luminol-ferricyanide reaction
    Lv, Y
    Zhang, ZJ
    He, DY
    Hu, YF
    [J]. ANALYTICAL SCIENCES, 2003, 19 (04) : 625 - 627
  • [27] Sensitive determination of captopril by flow injection analysis with chemiluminescence detection based on the enhancement of the luminol reaction
    Economou, A
    Themelis, DG
    Theodoridis, G
    Tzanavaras, PD
    [J]. ANALYTICA CHIMICA ACTA, 2002, 463 (02) : 249 - 255
  • [28] Flow injection chemiluminescence determination of dobutamine hydrochloride injection using luminol-ferricyanide/ferrocyanide system
    Liu, HY
    Zhang, L
    Zhou, JM
    Hao, YH
    He, PG
    Fang, YZ
    [J]. ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 125 - 129
  • [29] Determination of adenosine 5′-triphosphate by flow injection with luminol chemiluminescence detection using immobilized alkaline phosphatase enzyme reactor
    Anwar, M
    Yaqoob, M
    Nabi, A
    [J]. JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2005, 27 (06): : 615 - 620
  • [30] Sensitive determination of ketoprofen using flow injection with chemiluminescence detection
    Zhuang, Yafeng
    Song, Hengli
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (03) : 824 - 828