Determination of nanomolar concentrations of phosphate in freshwaters using flow injection with luminol chemiluminescence detection

被引:78
|
作者
Yaqoob, M
Nabi, A
Worsfold, PJ
机构
[1] Univ Plymouth, Sch Earth Ocean & Environm Sci, Plymouth PL4 8AA, Devon, England
[2] Univ Plymouth, Plymouth Environm Res Ctr, Plymouth PL4 8AA, Devon, England
[3] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
chemilummescence; flow injection analysis; phosphate; heteropoly acid; freshwaters;
D O I
10.1016/j.aca.2003.12.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid flow injection (FI) method is reported for the determination of phosphate (as molybdate reactive P) in freshwaters based on luminol chemiluminescence (CL) detection. The molybdophosphoric heteropoly acid formed by phosphate and ammonium molybdate in acidic conditions generated chemiluminescence emission via the oxidation of luminol. The detection limit (3 x standard deviation of blank) was 0.03 mug P l(-1) (1.0 nM), with a sample throughput of 180 h(-1). The calibration graph was linear over the range 0.032-3.26 mug P l(-1) (r(2) = 0.9880) with relative standard deviations (n = 4) in the range 1.2-4.7%. Interfering cations (Ca(II), Mg(II), Ni(II), Zn(II), Cu(II), Co(II), Fe(II) and Fe(III)) were removed by passing the sample through an in-line iminodiacetate chelating column. Silicate interference (at 5 mg Si l(-1)) was effectively masked by the addition of tartaric acid and other common anions (Cl(-), SO(4)(2-), HCO(3)(-), NO(3)(-) and NO(2)(-)) did not interfere at their maximum admissible concentrations in freshwaters. The method was applied to freshwater samples and the results (26.1 +/- 1.1-62.0 +/- 0.4 mug P l(-1)) were not significantly different (P = 0.05) from results obtained using a segmented flow analyser method with spectrophotometric detection (24.4 +/- 4.45-84.0 +/- 16.0 mug P l(-1)). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [1] Determination of silicate in freshwaters using flow injection with luminol chemiluminescence detection
    Yaqoob, M
    Nabi, A
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 2004, 519 (02) : 137 - 142
  • [2] Determination of Nitrite and Nitrate in Freshwaters using Flow Injection Luminol Chemiluminescence Detection
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    [J]. ACTA CHIMICA SLOVENICA, 2011, 58 (03) : 569 - 575
  • [3] Flow Injection Determination of Mo(VI), in Freshwaters with Luminol Chemiluminescence Detection
    Attiq-Ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    [J]. JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2009, 31 (01): : 74 - 79
  • [4] Determination of arsenic(V) in freshwaters by flow injection with luminol chemiluminescence detection
    Attiq-Ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (09) : 603 - 612
  • [5] Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection
    Yaqoob, Mohammad
    Biot, Beatriz Folgado
    Nabi, Abdul
    Worsfold, Paul J.
    [J]. LUMINESCENCE, 2012, 27 (05) : 419 - 425
  • [6] Determination of phosphate in freshwaters by flow injection with immobilized enzyme and chemiluminescence detection
    Yaqoob, M
    Anwar, M
    Nabi, A
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2005, 85 (07) : 451 - 459
  • [7] Determination of silicate in freshwaters using flow injection with luminol chemiluminescence detection (vol 519, pg 137, 2004)
    Yaqoob, M
    Nabi, A
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 2005, 531 (01) : 161 - 161
  • [8] Determination of subnanomolar concentrations of vanadium in environmental water samples using flow injection with luminol chemiluminescence detection
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    [J]. LUMINESCENCE, 2011, 26 (06) : 403 - 409
  • [9] Determination of thyroxine in pharmaceuticals using flow injection with luminol chemiluminescence inhibition detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    [J]. LUMINESCENCE, 2006, 21 (03) : 174 - 178
  • [10] Determination of iron in blood serum using flow injection with luminol chemiluminescence detection
    Waseem, A
    Yaqoob, M
    Nabi, A
    [J]. LUMINESCENCE, 2004, 19 (06) : 333 - 338