Analysis of fumonisins in corn-based food by liquid chromatography with fluorescence and mass spectrometry detectors

被引:45
|
作者
Silva, Liliana [1 ]
Fernandez-Franzon, Monica [2 ]
Font, Guillermina [2 ]
Pena, Angelina [1 ]
Silveira, Irene [1 ]
Lino, Celeste [1 ]
Manes, Jordi [2 ]
机构
[1] Univ Coimbra, Fac Pharm, Grp Bromatol CEF, P-3000295 Coimbra, Portugal
[2] Univ Valencia, Fac Pharm, Lab Bromatol & Toxicol, E-46100 Valencia, Spain
关键词
Fumonisins; Fluorescence; Mass detection; Tandem mass detection; Food analysis; FUSARIUM MYCOTOXINS; PORTUGUESE MAIZE; B-1; QUANTIFICATION; CLEANUP;
D O I
10.1016/j.foodchem.2008.06.080
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The presented procedure involves an extraction with methanol-water, centrifugation and cleanup with immunoaffinity columns. A comparison study between fluorescence detector, mass spectrometry, and tandem mass spectrometry with a triple quadrupole (QqQ) analyzer using an electrospray ionisation interface for the determination of fumonisin B-1 and B-2 in corn-based products has been performed. Limits of quantification obtained by the three detectors were lower than the maximum levels established by European Commission. Liquid chromatography coupled to tandem mass spectrometry provides higher sensitivity (12 mu g kg(-1) for fumonisins B-1 and B-2) when compared to mass spectrometry (40 mu g kg(-1) for both fumonisins). and fluorescence detection (20 mu g kg(-1) for fumonisin B-1 and 15 mu g kg(-1) for 132), and also showed to be more precise. At 150 and 250 mu g kg(-1) spiking levels, the recovery rates for fumonisin B, and 132 in corn products varied from 79% to 102%, with a relative standard deviation ranging from 9% to 17%. A critical assessment including advantages and drawbacks of each technique is presented. A total of 41 organic and non-organic corn-based food samples from Valencia markets were analyzed. Seven samples were contaminated with levels ranging from 68 mu g kg(-1) to 922 mu g kg(-1) of fumonisin B, and 42 mu g kg(-1) to 640 mu g kg(-1) of fumonisin B-2. Only one sample exceeded the maximum level for the sum of fumonisin B-1 and B-2, proposed for corn products in a recent EU regulation. The contamination frequency of organic corn samples (40%) was higher than non-organic ones (3.7%), and contained higher levels of fumonisin B-1 and B-2. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1031 / 1037
页数:7
相关论文
共 50 条
  • [21] Liquid Chromatography-Mass Spectrometry in the Analysis of Pesticide Residues in Food
    Anna Stachniuk
    Emilia Fornal
    Food Analytical Methods, 2016, 9 : 1654 - 1665
  • [22] Liquid Chromatography-Mass Spectrometry in the Analysis of Pesticide Residues in Food
    Stachniuk, Anna
    Fornal, Emilia
    FOOD ANALYTICAL METHODS, 2016, 9 (06) : 1654 - 1665
  • [23] Studies on extraction of fumonisins from rice, corn-based foods and beans
    Scott P.M.
    Lawrence G.A.
    Lombaert G.A.
    Mycotoxin Research, 1999, 15 (2) : 50 - 60
  • [24] Analysis of cannabinoids by liquid chromatography— Thermospray mass spectrometry and liquid chromatography— Tandem mass spectrometry
    K. Ndjoko
    J. -L. Wolfender
    K. Hostettmann
    Chromatographia, 1998, 47 : 72 - 76
  • [25] Analysis of cannabinoids by liquid chromatography - Thermospray mass spectrometry and liquid chromatography - Tandem mass spectrometry
    Ndjoko, K
    Wolfender, JL
    Hostettmann, K
    CHROMATOGRAPHIA, 1998, 47 (1-2) : 72 - 76
  • [26] Comprehensive Liquid Chromatography and Other Liquid-Based Comprehensive Techniques Coupled to Mass Spectrometry in Food Analysis
    Cacciola, Francesco
    Donato, Paola
    Sciarrone, Danilo
    Dugo, Paola
    Mondello, Luigi
    ANALYTICAL CHEMISTRY, 2017, 89 (01) : 414 - 429
  • [27] Nontarget Screening Methods for the Analysis of Contaminant Residues in Food Matrixes by Gas Chromatography/Mass Spectrometry and Liquid Chromatography/Mass Spectrometry
    Banerjee, Kaushik
    JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (06) : 1659 - 1660
  • [28] Liquid Chromatography and Mass Spectrometry in Food Allergen Detection
    Faeste, Christiane Kruse
    Ronning, Helene Thorsen
    Christians, Uwe
    Granum, Per Einar
    JOURNAL OF FOOD PROTECTION, 2011, 74 (02) : 316 - 345
  • [29] Liquid chromatography-mass spectrometry in food safety
    Malik, Ashok Kumar
    Blasco, Cristina
    Pico, Yolanda
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (25) : 4018 - 4040
  • [30] Robotic automated clean-up for detection of fumonisins B1 and B2 in corn and corn-based feed by high-performance liquid chromatography
    Dilkin, P
    Mallmann, CA
    de Almeida, CAA
    Corrêa, B
    JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) : 151 - 157