Variability of landmark acquisition affects tunnel calculation in image-free ACL navigation

被引:8
|
作者
Shafizadeh, Sven [1 ]
Balke, Maurice [1 ]
Hagn, Ulrich [2 ]
Grote, Stefan [3 ]
Bouillon, Bertil [1 ]
Banerjee, Marc [1 ]
机构
[1] Univ Witten Herdecke, Cologne Merheim Med Ctr, Dept Trauma & Orthopaed Surg, D-51109 Cologne, Germany
[2] Hosp Cologne Porz, Dept Surg, D-51149 Cologne, Germany
[3] Univ Munich, Dept Trauma Hand & Reconstruct Surg, Grosshadern Hosp Munich, D-81377 Munich, Germany
关键词
ACL; Tunnel positions; Navigation; Variability; Landmark acquisition; ANTERIOR CRUCIATE LIGAMENT; TOTAL KNEE ARTHROPLASTY; POSTEROLATERAL BUNDLES; SINGLE-BUNDLE; RECONSTRUCTION; PLACEMENT; SYSTEM; VALIDATION; REVISION; IDENTIFICATION;
D O I
10.1007/s00167-014-2963-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to determine the inter- and intraobserver variability of intraarticular landmark identification for tunnel position calculation in image-free anterior cruciate ligament (ACL) navigation. In a test/retest scenario, thirteen experienced ACL surgeons (> 50 reconstructions year) experienced in image-free ACL navigation were asked to identify the landmarks required for image-free ACL navigation in the same cadaver knee. Landmark positions were registered using a fluoroscopic ACL navigation system. Positions were determined using validated radiological measurement methods. For variability analysis, mean positions, deviations between the test/retest positions, standard deviations (SD) and range were calculated. Interobserver analysis showed a mean variability (SD) for the tibial landmark positions of 3.0 mm with deviations of up to 24.3 mm (range). Mean femoral landmark variability was 2.9 mm (SD) with deviations of up to 11.3 mm (range). Intraobserver analysis showed a tibial reproducibility of 2.2 mm (SD 2.0 mm; range 10.9 mm) and a femoral of 1.9 mm (SD 1.9 mm; range 10.4 mm). The data of the presented study suggest that a considerable inter- and intraobserver variability in intraarticular landmark identification exists. Reasonable ranges were found that have to be considered as a potential risk for miscalculation of tunnel positions in image-free ACL reconstruction. Landmark acquisition affects tunnel calculation in image-free ACL. IV.
引用
收藏
页码:1917 / 1924
页数:8
相关论文
共 35 条
  • [31] Clinical advantages of image-free navigation system using surface-based registration in anatomical anterior cruciate ligament reconstruction
    Byung Hoon Lee
    Dong Ho Kum
    Im Joo Rhyu
    Youngjun Kim
    Hyunchul Cho
    Joon Ho Wang
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3556 - 3564
  • [32] Comparative Study of Opening-Wedge High Tibial Osteotomy With and Without a Combined Computed Tomography-Based and Image-Free Navigation System
    Akamatsu, Yasushi
    Kobayashi, Hideo
    Kusayama, Yoshihiro
    Kumagai, Ken
    Saito, Tomoyuki
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (10): : 2072 - 2081
  • [33] Intraoperative fluoroscopy shows better agreement and interchangeability in tibial tunnel location during single bundle anterior cruciate ligament reconstruction with postoperative three-dimensional computed tomography compared with an intraoperative image-free navigation system
    Oshima, Takeshi
    Nakase, Junsuke
    Ohashi, Yoshinori
    Shimozaki, Kengo
    Asai, Kazuki
    Tsuchiya, Hiroyuki
    KNEE, 2020, 27 (03): : 809 - 816
  • [34] Accuracy of image-free navigation in intraoperative leg length change from total hip arthroplasty using evaluations from 2D and 3D measurements
    Shine Tone
    Masahiro Hasegawa
    Yohei Naito
    Hiroki Wakabayashi
    Akihiro Sudo
    BMC Musculoskeletal Disorders, 22
  • [35] Accuracy of image-free navigation in intraoperative leg length change from total hip arthroplasty using evaluations from 2D and 3D measurements
    Tone, Shine
    Hasegawa, Masahiro
    Naito, Yohei
    Wakabayashi, Hiroki
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)