Variability of landmark acquisition affects tunnel calculation in image-free ACL navigation

被引:8
|
作者
Shafizadeh, Sven [1 ]
Balke, Maurice [1 ]
Hagn, Ulrich [2 ]
Grote, Stefan [3 ]
Bouillon, Bertil [1 ]
Banerjee, Marc [1 ]
机构
[1] Univ Witten Herdecke, Cologne Merheim Med Ctr, Dept Trauma & Orthopaed Surg, D-51109 Cologne, Germany
[2] Hosp Cologne Porz, Dept Surg, D-51149 Cologne, Germany
[3] Univ Munich, Dept Trauma Hand & Reconstruct Surg, Grosshadern Hosp Munich, D-81377 Munich, Germany
关键词
ACL; Tunnel positions; Navigation; Variability; Landmark acquisition; ANTERIOR CRUCIATE LIGAMENT; TOTAL KNEE ARTHROPLASTY; POSTEROLATERAL BUNDLES; SINGLE-BUNDLE; RECONSTRUCTION; PLACEMENT; SYSTEM; VALIDATION; REVISION; IDENTIFICATION;
D O I
10.1007/s00167-014-2963-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to determine the inter- and intraobserver variability of intraarticular landmark identification for tunnel position calculation in image-free anterior cruciate ligament (ACL) navigation. In a test/retest scenario, thirteen experienced ACL surgeons (> 50 reconstructions year) experienced in image-free ACL navigation were asked to identify the landmarks required for image-free ACL navigation in the same cadaver knee. Landmark positions were registered using a fluoroscopic ACL navigation system. Positions were determined using validated radiological measurement methods. For variability analysis, mean positions, deviations between the test/retest positions, standard deviations (SD) and range were calculated. Interobserver analysis showed a mean variability (SD) for the tibial landmark positions of 3.0 mm with deviations of up to 24.3 mm (range). Mean femoral landmark variability was 2.9 mm (SD) with deviations of up to 11.3 mm (range). Intraobserver analysis showed a tibial reproducibility of 2.2 mm (SD 2.0 mm; range 10.9 mm) and a femoral of 1.9 mm (SD 1.9 mm; range 10.4 mm). The data of the presented study suggest that a considerable inter- and intraobserver variability in intraarticular landmark identification exists. Reasonable ranges were found that have to be considered as a potential risk for miscalculation of tunnel positions in image-free ACL reconstruction. Landmark acquisition affects tunnel calculation in image-free ACL. IV.
引用
收藏
页码:1917 / 1924
页数:8
相关论文
共 35 条
  • [1] Variability of landmark acquisition affects tunnel calculation in image-free ACL navigation
    Sven Shafizadeh
    Maurice Balke
    Ulrich Hagn
    Stefan Grote
    Bertil Bouillon
    Marc Banerjee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1917 - 1924
  • [2] An ACL reconstruction planning method based on isometry with image-free navigation
    Robotics Institute, BeiHang University, Beijing 100191, China
    Gaojishu Tongxin, 2009, 8 (844-849):
  • [3] Intra- and Intersurgeon Variability in Image-free Navigation System for THA
    Ohashi, Hirotsugu
    Matsuura, Masanori
    Okamoto, Yusaku
    Okajima, Yoshiaki
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) : 2305 - 2309
  • [4] Accuracy of image-free navigation for severely deformed knees
    Minoru Takasaki
    Shuichi Matsuda
    Shingo Fukagawa
    Hiroaki Mitsuyasu
    Hiromasa Miura
    Yukihide Iwamoto
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 763 - 768
  • [5] Accuracy of image-free navigation for severely deformed knees
    Takasaki, Minoru
    Matsuda, Shuichi
    Fukagawa, Shingo
    Mitsuyasu, Hiroaki
    Miura, Hiromasa
    Iwamoto, Yukihide
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (06) : 763 - 768
  • [6] Effects of incorrect acquisition of anatomical landmarks on image-free navigation-assisted total knee arthroplasty
    Cinotti, Gianluca
    Ferrari, Emiliano
    Lucioli, Niccolo
    Della Rocca, Antonello
    CURRENT ORTHOPAEDIC PRACTICE, 2009, 20 (05): : 546 - 551
  • [7] Accuracy of an image-free cup navigation system -: an anatomical study
    Kalteis, T
    Beckmann, J
    Herold, T
    Zysk, S
    Bäthis, H
    Perlick, L
    Grifka, J
    BIOMEDIZINISCHE TECHNIK, 2004, 49 (09): : 257 - 262
  • [8] Development of an Image-Free Navigation Tool for High Tibial Osteotomy
    Lorenz, Stephan
    Morgenstern, Mario
    Imhoff, Andreas B.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2007, 17 (01) : 58 - 65
  • [9] Reliability of Image-Free Navigation to Monitor Lower-Limb Alignment
    Pearle, Andrew D.
    Goleski, Patrick
    Musahl, Volker
    Kendoff, Daniel
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 90 - 94
  • [10] Image-free cusp navigation inaccuracy: A two-study approach
    Blendea, Sorin
    Troccaz, Jocelyne
    Ravey, Jean-Noel
    Merloz, Philippe
    COMPUTER AIDED SURGERY, 2007, 12 (03) : 176 - 180