Dynamic shape modeling of the mitral valve from real-time 3D ultrasound images using continuous medial representation

被引:1
|
作者
Pouch, Alison M. [1 ]
Yushkevich, Paul A. [2 ]
Jackson, Benjamin M. [3 ]
Gorman, Joseph H., III [3 ]
Gorman, Robert C. [3 ]
Sehgal, Chandra M. [2 ]
机构
[1] Univ Penn, Dept Bioengn, 210 S 33rd St, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Radiol, 3400 Spruce St, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Surg, 3400 Spruce St, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
3D ultrasound; continuous medial representation; deformable modeling; statistical shape analysis; mitral valve; 3-DIMENSIONAL ECHOCARDIOGRAPHY; REGURGITATION; REGISTRATION; LEAFLET; BRAIN; HEART;
D O I
10.1117/12.910708
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Purpose: Patient-specific shape analysis of the mitral valve from real-time 3D ultrasound (rt-3DUS) has broad application to the assessment and surgical treatment of mitral valve disease. Our goal is to demonstrate that continuous medial representation (cm-rep) is an accurate valve shape representation that can be used for statistical shape modeling over the cardiac cycle from rt-3DUS images. Methods: Transesophageal rt-3DUS data acquired from 15 subjects with a range of mitral valve pathology were analyzed. User-initialized segmentation with level sets and symmetric diffeomorphic normalization delineated the mitral leaflets at each time point in the rt-3DUS data series. A deformable cm-rep was fitted to each segmented image of the mitral leaflets in the time series, producing a 4D parametric representation of valve shape in a single cardiac cycle. Model fitting accuracy was evaluated by the Dice overlap, and shape interpolation and principal component analysis (PCA) of 4D valve shape were performed. Results: Of the 289 3D images analyzed, the average Dice overlap between each fitted cm-rep and its target segmentation was 0.880 +/- 0.018 (max=0.912, min=0.819). The results of PCA represented variability in valve morphology and localized leaflet thickness across subjects. Conclusion: Deformable medial modeling accurately captures valve geometry in rt-3DUS images over the entire cardiac cycle and enables statistical shape analysis of the mitral valve.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Real-time 3D transoesophageal echocardiography visualization of congenital double orifice mitral valve
    Wang, Lufang
    Fang, Lingyun
    Li, Yuman
    Xie, Mingxing
    Zhang, Li
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2022, 23 (06) : E263 - E263
  • [32] Evaluation of early dysfunction of a prosthetic mitral valve by real-time 3D transesophageal echocardiography
    Aytekin, Saide
    Tayyareci, Yelda
    Yurdakul, Selen
    Sagbas, Ertan
    [J]. TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2012, 40 (04): : 390 - 390
  • [33] Real time representation of 3D sensor depth images
    Applied Electronics Department, University Politehnica Timisoara, V Parvan 2, Timisoara, Romania
    不详
    [J]. WSEAS Trans. Electron., 2008, 3 (65-71):
  • [34] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (02): : 239 - 251
  • [35] Real-time freehand 3D ultrasound imaging
    Chen, Zhenping
    Huang, Qinghua
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2018, 6 (01): : 74 - 83
  • [36] Real-time tools for freehand 3D ultrasound
    Prager, R
    Gee, A
    Berman, L
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 1016 - 1023
  • [37] REAL-TIME 3D FILTERING OF ULTRASOUND DATASETS
    Kang, Dong-Soo
    Kwon, Koojoo
    Lee, Eun-Seok
    Lee, Sang-Chul
    Shin, Byeong-Seok
    [J]. HEALTHINF 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON HEALTH INFORMATICS, 2010, : 473 - 476
  • [38] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Graham, Andrew H. Gee
    Treece, Graham M.
    [J]. MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [39] Mass-spring systems for simulating mitral valve repair using 3D ultrasound images
    Skornitzke, Stephan
    Schummers, Georg
    Schreckenberg, Marcus
    Ender, Joerg
    Eibel, Sarah
    Bungartz, Hans-Joachim
    Kauczor, Hans-Ulrich
    Stiller, Wolfram
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 45 : 26 - 35
  • [40] REAL-TIME 3D RECONSTRUCTION FROM IMAGES TAKEN FROM AN UAV
    Zingoni, A.
    Diani, M.
    Corsini, G.
    Masini, A.
    [J]. ISPRS GEOSPATIAL WEEK 2015, 2015, 40-3 (W3): : 313 - 319