Dynamic shape modeling of the mitral valve from real-time 3D ultrasound images using continuous medial representation

被引:1
|
作者
Pouch, Alison M. [1 ]
Yushkevich, Paul A. [2 ]
Jackson, Benjamin M. [3 ]
Gorman, Joseph H., III [3 ]
Gorman, Robert C. [3 ]
Sehgal, Chandra M. [2 ]
机构
[1] Univ Penn, Dept Bioengn, 210 S 33rd St, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Radiol, 3400 Spruce St, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Surg, 3400 Spruce St, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
3D ultrasound; continuous medial representation; deformable modeling; statistical shape analysis; mitral valve; 3-DIMENSIONAL ECHOCARDIOGRAPHY; REGURGITATION; REGISTRATION; LEAFLET; BRAIN; HEART;
D O I
10.1117/12.910708
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Purpose: Patient-specific shape analysis of the mitral valve from real-time 3D ultrasound (rt-3DUS) has broad application to the assessment and surgical treatment of mitral valve disease. Our goal is to demonstrate that continuous medial representation (cm-rep) is an accurate valve shape representation that can be used for statistical shape modeling over the cardiac cycle from rt-3DUS images. Methods: Transesophageal rt-3DUS data acquired from 15 subjects with a range of mitral valve pathology were analyzed. User-initialized segmentation with level sets and symmetric diffeomorphic normalization delineated the mitral leaflets at each time point in the rt-3DUS data series. A deformable cm-rep was fitted to each segmented image of the mitral leaflets in the time series, producing a 4D parametric representation of valve shape in a single cardiac cycle. Model fitting accuracy was evaluated by the Dice overlap, and shape interpolation and principal component analysis (PCA) of 4D valve shape were performed. Results: Of the 289 3D images analyzed, the average Dice overlap between each fitted cm-rep and its target segmentation was 0.880 +/- 0.018 (max=0.912, min=0.819). The results of PCA represented variability in valve morphology and localized leaflet thickness across subjects. Conclusion: Deformable medial modeling accurately captures valve geometry in rt-3DUS images over the entire cardiac cycle and enables statistical shape analysis of the mitral valve.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Development of a semi-automated method for mitral valve modeling with medial axis representation using 3D ultrasound
    Pouch, Alison M.
    Yushkevich, Paul A.
    Jackson, Benjamin M.
    Jassar, Arminder S.
    Vergnat, Mathieu
    Gorman, Joseph H., III
    Gorman, Robert C.
    Sehgal, Chandra M.
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 933 - 950
  • [2] Characterization of Degenerative Mitral Valve Disease Using Morphologic Analysis of Real-Time 3D Echocardiographic Images
    Chandra, S.
    Salgo, I. S.
    Sugeng, L.
    Weinert, L.
    Takeuchi, M.
    Tsang, W.
    Lang, R. M.
    Mor-Avi, V.
    [J]. COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 887 - 890
  • [3] From Real-Time 3D Echocardiography to Mitral Valve Finite Element Analysis: A Novel Modeling Approach
    Votta, E.
    Arnoldi, A.
    Stevanella, M.
    Veronesi, F.
    Tamborini, G.
    Alamanni, F.
    Calani, E. G.
    Redaelli, A.
    [J]. COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 1 - +
  • [4] Case images Prosthetic mitral valve thrombosis demonstrated by real-time 3D transesophageal echocardiography
    Ozkan, Mehmet
    Kaya, Hasan
    Biteker, Murat
    Duran, Nilfer Eksi
    [J]. TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2009, 37 (03): : 209 - 209
  • [5] Improved image guidance technique for minimally invasive mitral valve repair using real-time tracked 3D ultrasound
    Rankin, Adam
    Moore, John
    Bainbridge, Daniel
    Peters, Terry
    [J]. MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [6] Real-time 3D transoesophageal measurement of the mitral valve area in patients with mitral stenosis
    Dreyfus, Julien
    Brochet, Eric
    Lepage, Laurent
    Attias, David
    Cueff, Caroline
    Detaint, Delphine
    Himbert, Dominique
    Iung, Bernard
    Vahanian, Alec
    Messika-Zeitoun, David
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (10): : 750 - 755
  • [7] Dynamic Fire 3D Modeling Using a Real-time Stereovision System
    Rossi, L.
    Akhloufi, M.
    [J]. TECHNOLOGICAL DEVELOPMENTS IN EDUCATION AND AUTOMATION, 2010, : 33 - +
  • [8] Real-time Tracking of Deformable Target in 3D Ultrasound Images
    Royer, Lucas
    Marchal, Maud
    Le Bras, Anthony
    Dardenne, Guillaume
    Krupa, Alexandre
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2015, : 2430 - 2435
  • [9] 3D geometry of mitral annulus in mitral valve prolapse in comparison with normal: Real-time 3D echocardiography study
    Park, SM
    Chai, J
    Jeon, MJ
    Lee, CK
    Kim, DH
    Park, KS
    Lee, WH
    Kwan, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 281A - 281A
  • [10] Quantification of Aortic Valve Stenosis Using Transesophageal Real-Time 3D Echocardiographic Images
    Veronesi, F.
    Corsi, C.
    Mor-Avi, V.
    Sugeng, L.
    Wienert, L.
    Lang, R. M.
    Lamberti, C.
    [J]. CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 37 - +