The orthopaedic research institute-ankle strength testing system: Inter-rater and intra-rater reliability testing

被引:5
|
作者
Paoloni, JA [1 ]
Appleyard, RC [1 ]
Murrell, GA [1 ]
机构
[1] Univ New S Wales, Orthopaed Res Inst, Sydney, NSW 2217, Australia
关键词
D O I
10.1177/107110070202300206
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Achilles tendinosis is a degenerative overuse tendinopathy involving the primary ankle plantarflexors, namely the soleus and gastrocnemius muscles forming the tendo Achilles. The Orthopaedic Research Institute-Ankle Strength Testing System (ORI-ASTS) was designed to record objective measurements of force generated with a resisted ankle plantarflexion test. Testing normal subjects (n=6) was used to establish the reliability of the ORI-ASTS for measuring ankle plantarflexion force. Testing patients with Achilles tendonitis (n=5) over time and comparing Achilles tendon analogue pain scores to ankle plantarflexion force measurements was used to assess the validity of the ORI-ASTS for monitoring progression of Achilles tendinopathy. Inter-rater reliability of the ORI-ASTS with normal subjects was excellent, with single measure intraclass correlation coefficients (ICC) for right mean peak force of 0.92, left mean peak force of 0.96, right mean total force of 0.89, left mean total force of 0.91. The ORI-ASTS also had excellent intra-rater reliability for normal subjects with the following single measure ICC scores: right mean force 0.96, left mean force 0.92, right mean total force 0.97, left mean total force 0.92. The relative technical errors of measurement were calculated from these results, and ranged from 1.0% to 2.7%. Testing patients with Achilles tendinosis (n=5), and comparing analogue activity pain scores to ORI-ASTS testing demonstrated a strong negative relationship between the two parameters (Spearman Rho -0.87 to -1.0, Kendall tau b -0.82 to -1.0). The relationship was statistically significant at the p=0.01 level for two of the five patients. The ORI-ASTS shows excellent reliability for testing ankle plantarflexor force, and appears valid for objectively assessing and monitoring patients with Achilles tendinosis.
引用
收藏
页码:112 / 117
页数:6
相关论文
共 50 条
  • [21] Measuring shoulder external and internal rotation strength and range of motion: comprehensive intra-rater and inter-rater reliability study of several testing protocols
    Cools, Ann M.
    De Wilde, Lieven
    Van Tongel, Alexander
    Ceyssens, Charlotte
    Ryckewaert, Robin
    Cambier, Dirk C.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (10) : 1454 - 1461
  • [22] THE INTER-RATER AND INTRA-RATER RELIABILITY ANALYSIS OF WORKPLACE ERGONOMIC RISK ASSESSMENT
    Rohani, Jafri Mohd.
    Adeyemi, Ademola James
    Abd Aziz, Roseni
    Rani, Mat Rebi Abdul
    [J]. JURNAL TEKNOLOGI, 2018, 80 (01): : 53 - 59
  • [23] INTRA-RATER AND INTER-RATER RELIABILITY AT THE ITEM LEVEL OF THE ACTION RESEARCH ARM TEST FOR PATIENTS WITH STROKE
    Nordin, Asa
    Alt Murphy, Margit
    Danielsson, Anna
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2014, 46 (08) : 738 - 745
  • [24] Inter- and intra-rater reliability of fluoroscopic cough stress testing
    Glancz, L. J.
    Cartwright, R.
    Cardozo, L.
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2010, 30 (05) : 492 - 495
  • [25] Inter-rater and Intra-rater Reliability of the Chinese Version of the Action Research Arm Test in People With Stroke
    Zhao, Jiang-Li
    Chen, Pei-Ming
    Zhang, Tao
    Li, Hai
    Lin, Qiang
    Mao, Yu-Rong
    Huang, Dong-Feng
    [J]. FRONTIERS IN NEUROLOGY, 2019, 10
  • [26] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Wei, Chin-Hung
    Shen, Shih-Chiang
    Duh, Yih-Cherng
    Tsai, Kuei-Yen
    Chen, Hsin-An
    Huang, Shih-Wei
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (09): : 6586 - 6591
  • [27] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Chin-Hung Wei
    Shih-Chiang Shen
    Yih-Cherng Duh
    Kuei‐Yen Tsai
    Hsin-An Chen
    Shih-Wei Huang
    [J]. Surgical Endoscopy, 2022, 36 : 6586 - 6591
  • [28] Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers
    Greene, Amanda
    Lasner, Andrea
    Deu, Rajwinder
    Oliphant, Seth
    Johnson, Kenneth
    [J]. PHYSIOTHERAPY THEORY AND PRACTICE, 2019, 35 (01) : 94 - 99
  • [29] Measuring the quality of life in mild to very severe dementia: Testing the inter-rater and intra-rater reliability of the German version of the QUALIDEM
    Dichter, Martin Nikolaus
    Schwab, Christian G. G.
    Meyer, Gabriele
    Bartholomeyczik, Sabine
    Dortmann, Olga
    Halek, Margareta
    [J]. INTERNATIONAL PSYCHOGERIATRICS, 2014, 26 (05) : 825 - 836
  • [30] Inter-rater and Intra-rater Reliability of a Mobile App Method to Measure Lumbar Lordosis
    Gnanasigamani, Jency Thangasheela
    Ramalingam, Vinodhkumar
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)