Serial observation of PK Papyrus covered stent implantation for coronary artery perforation by optical coherence tomography and coronary angioscopy: a case report

被引:0
|
作者
Ishiguro, Nobuo [1 ]
Aoyama, Hidekazu [1 ]
Kametani, Ryosuke [1 ]
机构
[1] Nagoya Tokushukai Gen Hosp, Dept Cardiol, 2-52 Kouzoji Cho Kita, Kasugai, Aichi 4870016, Japan
关键词
Coronary artery perforation; PK Papyrus; Optical coherence tomography; Coronary angioscopy; Case report;
D O I
10.1093/ehjcr/ytac438
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Coronary artery perforation is a rare but life-threatening complication of percutaneous coronary intervention. We present a case of coronary artery perforation treated with a PK Papyrus covered stent. Neointimal coverage evaluation was performed using optical coherence tomography (OCT) and coronary angioscopy (CAS) at 3 and 9 months after stent implantation. Case summary A 63-year-old man was admitted to our hospital with worsening effort angina over 3 months. Coronary angiography revealed severe stenosis in the proximal segment of the left anterior descending artery. After stent implantation, coronary artery perforation occurred. We immediately sealed the perforation site using a PK Papyrus covered stent. The patient was discharged on postoperative day 4. OCT and CAS revealed incomplete neointimal coverage at the PK Papyrus covered stent strut 3 months after stent implantation. At 9 postoperative months, complete neointimal coverage was observed. We continued clopidogrel and edoxaban, but no clinical adverse events were encountered during the follow-up. Discussion To the best of our knowledge, this is the first report of a serial observation of PK Papyrus covered stent implantation for coronary artery perforation using OCT and CAS. In this case, OCT and CAS revealed complete neointimal coverage, without obvious thrombus, 9 months after PK Papyrus implantation. Based on the OCT and CAS findings, our report presents an appropriate follow-up strategy for the prevention of stent thrombosis when using a PK Papyrus covered stent, which will contribute to future research on the appropriate duration of dual antiplatelet therapy and evaluation of neointimal coverage.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] PK Papyrus coronary stent system: the ultrathin struts polyurethane-covered stent
    Barbero, Umberto
    Cerrato, Enrico
    Secco, Gioel Gabrio
    Tedeschi, Delio
    Belliggiano, Davide
    Pavani, Marco
    Moncalvo, Cinzia
    Tomassini, Francesco
    De Benedictis, Michele
    Doronzo, Baldassarre
    Varbella, Ferdinando
    FUTURE CARDIOLOGY, 2020, 16 (05) : 405 - 411
  • [22] Real-time observation of coronary artery perforation by intravascular ultrasound and optical coherence tomography
    Watabe, Hiroaki
    Sato, Akira
    Usami, Kyohei
    Hiraya, Daigo
    Hoshi, Tomoya
    Ieda, Masaki
    CORONARY ARTERY DISEASE, 2022, 31 (01) : E5 - E6
  • [23] Assessment of neointimal tissue characteristics in stent restenosis by optical coherence tomography and coronary angioscopy
    Kimura, S.
    Kuroda, S.
    Osaka, Y.
    Kawaguchi, N.
    Akiyama, D.
    Sugiyama, T.
    Kamiishi, T.
    Hikita, H.
    Takahashi, A.
    Isobe, M.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1005 - 1006
  • [24] Management of traumatic arteriovenous fistula affecting the posterior tibial artery with a PK Papyrus coronary covered stent
    Das, Vineet
    Skelton, Julia
    Bhutia, Sherab
    ANZ JOURNAL OF SURGERY, 2020, 90 (05) : 902 - 904
  • [25] PERONEAL ARTERIOVENOUS FISTULA SUCCESSFULLY TREATED WITH A PK PAPYRUS® CORONARY COVERED STENT
    Sawhney, Rahul
    Cubberley, Alex
    Christensen, Jared
    Potluri, Srinivasa P.
    Sayfo, Sameh
    Al-Azizi, Karim
    Thomas, Sibi P.
    Dib, Chadi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 3316 - 3316
  • [26] Very Late Stent Thrombosis after Sirolimus-Eluting Stent Implantation Observed Using Optical Coherence Tomography and Coronary Angioscopy
    Ikenaga, Hiroki
    Dai, Kazuoki
    Ishihara, Masaharu
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (11): : 557 - 558
  • [27] DIFFERENCE BETWEEN CORONARY ANGIOSCOPY AND OPTICAL COHERENCE TOMOGRAPHY IN THE ASSESSMENT OF NEOINTIMAL FINDINGS AT FOLLOW UP AFTER STENT IMPLANTATION
    Taichi, Nakamura
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1425 - 1425
  • [28] Serial Observations of In-Stent Restenosis Treated With Drug-Coated Balloon Angioplasty by Optical Coherence Tomography and Coronary Angioscopy A Case Series
    Murata, Nobuhiro
    Takayama, Tadateru
    Hiro, Takafumi
    INTERNATIONAL HEART JOURNAL, 2017, 58 (01) : 134 - 139
  • [29] Optical coherence tomography or intravascular ultrasound to optimize coronary stent implantation
    Alfonso, Fernando
    Prati, Francesco
    EUROPEAN HEART JOURNAL, 2017, 38 (42) : 3148 - 3151
  • [30] Evaluation of aneurysm after coronary stent implantation by optical coherence tomography
    Karabay, Can Yucel
    Kocabay, Gonenc
    Tasar, Onur
    Kalayci, Arzu
    Guler, Ahmet
    Kirma, Cevat
    KARDIOLOGIA POLSKA, 2013, 71 (06) : 659 - 659