Patient-Specific Model of Left Heart Anatomy, Dynamics and Hemodynamics from 4D TEE: A First Validation Study

被引:0
|
作者
Voigt, Ingmar [1 ,2 ]
Mansi, Tommaso [1 ]
Mihalef, Viorel [1 ]
Ionasec, Razvan Ioan [1 ]
Calleja, Anna [3 ]
Mengue, Etienne Assoumou [1 ]
Sharma, Puneet [1 ]
Houle, Helene [4 ]
Georgescu, Bogdan [1 ]
Hornegger, Joachim [2 ]
Comaniciu, Dorin [1 ]
机构
[1] Siemens Corp Res, Image Analyt & Informat, Princeton, NJ 08540 USA
[2] Univ Erlangen Nurnberg, Pattern Recognit Lab, Erlangen, Germany
[3] Ohio State Univ, Davis Heart & Lung Res Inst, Columbus, OH USA
[4] Ultrasound Siemens Hlthcare, Mountain View, CA USA
关键词
SIMULATION; FLOW;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Patient-specific models of the heart physiology have become powerful instruments able to improve the diagnosis and treatment of cardiac disease. A systemic representation of the whole organ is required to capture the complex functional and hemodynamical interdependencies among the anatomical structures. We propose a novel framework for personalized modeling of the left-side heart that integrates comprehensive data of the morphology, function and hemodynamics. Patient-specific fluid dynamics are computed over the entire cardiac cycle using embedded boundary and ghost fluid methods, constrained by the dynamics of highly detailed anatomical models. Personalized boundary conditions are determined by estimating cardiac shape and motion from 4D TEE images through robust discriminative learning methods. Qualitative and quantitative validation of the computed blood dynamics is performed against Doppler echocardiography measurements, following an original methodology. Results showed a high agreement between simulation and ground truth and a correlation of r = 0.85 (p < 0.0002675). To the best of our knowledge, this is the first time that computational fluid dynamics are simulated on a systemic and comprehensive patient-specific model of the heart and validated against routinely acquired clinical ground truth.
引用
收藏
页码:341 / 349
页数:9
相关论文
共 50 条
  • [21] Patient Specific Hemodynamics: Combined 4D Flow-Sensitive MRI and CFD
    Stalder, A. F.
    Liu, Z.
    Hennig, J.
    Korvink, J. G.
    Li, K. C.
    Markl, M.
    COMPUTATIONAL BIOMECHANICS FOR MEDICINE: SOFT TISSUES AND THE MUSCULOSKELETAL SYSTEM, 2011, : 27 - 38
  • [22] Patient-specific 3D hemodynamics modelling of left coronary artery under hyperemic conditions
    Kamangar, Sarfaraz
    Badruddin, Irfan Anjum
    Govindaraju, Kalimuthu
    Nik-Ghazali, N.
    Badarudin, A.
    Viswanathan, Girish N.
    Ahmed, N. J. Salman
    Khan, T. M. Yunus
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (08) : 1451 - 1461
  • [23] Patient-specific 3D hemodynamics modelling of left coronary artery under hyperemic conditions
    Sarfaraz Kamangar
    Irfan Anjum Badruddin
    Kalimuthu Govindaraju
    N. Nik-Ghazali
    A. Badarudin
    Girish N. Viswanathan
    N. J. Salman Ahmed
    T. M. Yunus Khan
    Medical & Biological Engineering & Computing, 2017, 55 : 1451 - 1461
  • [24] Patient-specific 4D Monte Carlo Dose Accumulation using Correspondence Model Based Motion Prediction
    Sentker, Thilo
    Madesta, Frederic
    Werner, Rene
    MEDICAL IMAGING 2019: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2019, 10951
  • [25] Patient-specific modelling of whole heart anatomy, dynamics and haemodynamics from four-dimensional cardiac CT images
    Mihalef, Viorel
    Ionasec, Razvan Ioan
    Sharma, Puneet
    Georgescu, Bogdan
    Voigt, Ingmar
    Suehling, Michael
    Comaniciu, Dorin
    INTERFACE FOCUS, 2011, 1 (03) : 286 - 296
  • [26] A 4D digital phantom for patient-specific simulation of brain CT perfusion protocols
    van den Boom, Rieneke
    Manniesing, Rashindra
    Oei, Marcel T. H.
    van der Woude, Willem-Jan
    Smit, Ewoud J.
    Laue, Hendrik O. A.
    van Ginneken, Bram
    Prokop, Mathias
    MEDICAL PHYSICS, 2014, 41 (07)
  • [27] Physics-based Patient-Specific Respiration Modeling for 4D Treatment Planning
    Shi, C.
    Eom, J.
    Vines, D.
    De, S.
    Xu, G. X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S649 - S649
  • [28] Intra left ventricular hemodynamics assessed using 4D flow MRI in the patient with left ventricular thrombus
    Sakakibara, T.
    Suwa, K.
    Kaneko, Y.
    Akita, K.
    Sato, R.
    Mogi, S.
    Naruse, Y.
    Ohtani, H.
    Saitoh, T.
    Saotome, M.
    Urushida, T.
    Maekawa, Y.
    EUROPEAN HEART JOURNAL, 2019, 40 : 196 - 196
  • [29] Patient-Specific Mechanical Characterization Of Abdominal Aortic Aneurysms Using 4D Ultrasound
    van Disseldorp, E. M. J.
    Petterson, N. J.
    Rutten, M. C. M.
    van de Vosse, F. N.
    van Sambeek, M. R. H. M.
    Lopata, R. G. P.
    ULTRASCHALL IN DER MEDIZIN, 2017, 38 (01): : 92 - 93
  • [30] Automatic left ventricular segmentation in 4D interventional ultrasound data using a patient-specific temporal synchronized shape prior
    Morais, Pedro
    Queiros, Sandro
    Pereira, Carla
    Moreira, Antonio H. J.
    Baptista, Maria J.
    Rodrigues, Nuno F.
    D'hooge, Jan
    Barbosa, Daniel
    Vilaca, Joao L.
    MEDICAL IMAGING 2019: IMAGE PROCESSING, 2019, 10949