The impact of random and systematic errors of MLC leaves on head-and-neck IMRT plans

被引:0
|
作者
Mu, G. [1 ]
Xia, P. [1 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
D O I
10.1118/1.2241339
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:2142 / 2142
页数:1
相关论文
共 50 条
  • [31] Nonrigid patient setup errors in the head-and-neck region
    Polat, Buelent
    Wilbert, Juergen
    Baier, Kurt
    Flentje, Michael
    Guckenberger, Matthias
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 (09) : 506 - 511
  • [32] Impact of oral cavity contouring on treatment planning in head-and-neck patients treated with IMRT techniques
    Prieto, I.
    Gomez, S.
    Marin, J. P.
    Perez, A. M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S629 - S630
  • [33] Skin and superficial doses in MLC-based head and neck IMRT
    Chung, H
    Kim, S
    Jin, H
    Dempsey, J
    Liu, C
    Palta, J
    Suh, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1844 - 1844
  • [34] Lens dose in MLC-based IMRT treatments of the head and neck
    Pawlicki, T
    Luxton, G
    Le, QT
    Findley, D
    Ma, CM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01): : 293 - 299
  • [35] Treatment Plans Comparison with Static-Gantry IMRT and RapidArcTM for Head-And-Neck Cancers Involving Cervical Lymph Nodes
    Yoo, S.
    Das, S.
    Wu, Q.
    Brizel, D.
    Yin, F.
    MEDICAL PHYSICS, 2010, 37 (06) : 3216 - +
  • [36] IMRT for head-and-neck cancer improves quality of life and reduces xerostomia
    Alexandra King
    Nature Clinical Practice Oncology, 2006, 3 (1): : 7 - 7
  • [37] Evaluation of MLC leaf positioning errors in dynamic IMRT plans using dynalogs files
    Olasolo Alonso, J.
    Gracia Ochoa, M.
    Pellejero Pellejero, S.
    Martin Albina, M. L.
    Fuentemilla Urio, N.
    Gallardo Rodriguez, N.
    Maneru Camara, F.
    Bragado Alvarez, L.
    Lozares Cordero, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S860 - S860
  • [38] Dosimetric impact of systematic MLC positional errors on step and shoot IMRT for prostate cancer: a planning study
    N. M. Ung
    C. S. Harper
    L. Wee
    Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 291 - 298
  • [39] Semiautomated head-and-neck IMRT planning using dose warping and scaling to robustly adapt plans in a knowledge database containing potentially suboptimal plans
    Schmidt, Matthew
    Lo, Joseph Y.
    Grzetic, Shelby
    Lutzky, Carly
    Brizel, David M.
    Das, Shiva K.
    MEDICAL PHYSICS, 2015, 42 (08) : 4428 - 4434
  • [40] Dosimetric impact of systematic MLC positional errors on step and shoot IMRT for prostate cancer: a planning study
    Ung, N. M.
    Harper, C. S.
    Wee, L.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (02) : 291 - 298