Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the LNE-LNHB, France and the BIPM in accelerator photon beams

被引:3
|
作者
Picard, S. [1 ]
Burns, D. T. [1 ]
Roger, P. [1 ]
Delaunay, F. [2 ]
Gouriou, J. [2 ]
Le Roy, M. [2 ]
Ostrowsky, A. [2 ]
Sommier, L. [2 ]
Vermesse, D. [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] CEA, LIST, Lab Natl Henri Becquerel LNE LNHB, F-91191 Gif Sur Yvette, France
关键词
D O I
10.1088/0026-1394/50/1A/06015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison of the dosimetry for accelerator photon beams was carried out between the Laboratoire National de Metrologie et d'Essais - Laboratoire National Henri Becquerel (LNE-LNHB) and the Bureau International des Poids et Mesures (BIPM) in March 2012. The comparison was based on the determination of absorbed dose to water for three radiation qualities at the LNE-LNHB. The comparison result, reported as a ratio of the LNE-LNHB and the BIPM evaluations, is 0.995 at 6 MV and 12 MV; 0.994 at 20 MV, with a combined standard uncertainty of 5 parts in 10(3) at all three energies. This result is the fourth in the on-going BIPM. RI(I)-K6 series of comparisons.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the LNE-LNHB, France and the BIPM in accelerator photon beams
    Kessler, C.
    Burns, D. T.
    Roger, P.
    Delaunay, F.
    Donois, M.
    Rapp, B.
    [J]. METROLOGIA, 2021, 58 (1A)
  • [2] Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the ARPANSA, Australia and the BIPM in accelerator photon beams
    Picard, S.
    Burns, D. T.
    Roger, P.
    Harty, P. D.
    Ramanathan, G.
    Lye, J. E.
    Wright, T.
    Butler, D. J.
    Cole, A.
    Oliver, C.
    Webb, D. V.
    [J]. METROLOGIA, 2014, 51
  • [3] Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the PTB, Germany and the BIPM in accelerator photon beams
    Picard, S.
    Burns, D. T.
    Roger, P.
    Allisy-Roberts, P. J.
    Kapsch, R. P.
    Krauss, A.
    [J]. METROLOGIA, 2011, 48
  • [4] Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the VSL, Netherlands and the BIPM in accelerator photon beams
    Picard, S.
    Burns, D. T.
    Roger, P.
    de Prez, L. A.
    Jansen, B. J.
    Pooter, J. A.
    [J]. METROLOGIA, 2017, 54
  • [5] Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the NIST, USA and the BIPM in accelerator photon beams
    Picard, S.
    Burns, D. T.
    Roger, P.
    Bateman, F. B.
    Tosh, R. E.
    Chen-Mayer, H.
    [J]. METROLOGIA, 2013, 50
  • [6] Comparison of the standards for absorbed dose to water of the METAS, Switzerland and the BIPM in accelerator photon beams (BIPM.RI(I)-K6)
    Kessler, C.
    Burns, D. T.
    Roger, P.
    Kottler, C.
    Voros, S.
    Peier, P.
    [J]. METROLOGIA, 2019, 56 (1A)
  • [7] Comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the PTB, Germany, and the BIPM, in accelerator photon beams
    Kessler, C.
    Burns, D.T.
    Roger, P.
    Krauss, A.
    Kapsch, R.-P.
    [J]. Metrologia, 2022, 59 (1 A)
  • [8] Comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the KRISS, Korea and the BIPM in accelerator photon beams
    Kessler, C.
    Burns, D. T.
    Picard, S.
    Roger, P.
    Kim, I. J.
    Kim, B. C.
    Kim, Y. H.
    Kim, J. H.
    Chung, J. P.
    Yi, C. Y.
    [J]. METROLOGIA, 2020, 57 (1A)
  • [9] Comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the NRC, Canada and the BIPM in accelerator photon beams
    Kessler, C.
    Burns, D.T.
    Roger, P.
    Muir, B.
    McEwen, M.
    [J]. Metrologia, 2022, 59 (1A)
  • [10] Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the LNE-LNHB, France and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Delaunay, F.
    Donois, M.
    [J]. METROLOGIA, 2013, 50