Active noise control in duct with a harmonic acoustic pneumatic source

被引:8
|
作者
Drant, Julien [1 ]
Micheau, Philippe [1 ]
Berry, Alain [1 ]
机构
[1] Univ Sherbrooke, Grp Acoust, 2500 Blvd Univ, Sherbrooke, PQ J1K 2R1, Canada
关键词
Active noise control; Acoustic pneumatic source;
D O I
10.1016/j.apacoust.2020.107860
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Electrodynamic loudspeakers usually used in active noise cancellation show several limitations due to the difficulty of embedding in complex harsh conditions, e.g. the conditions for active noise control of tonal turbofan noise. Instead, this study presents a Harmonic Acoustic Pneumatic Source (HAPS), designed to generate a controlled harmonic anti-noise from a pneumatic source. It is based on a controlled flow valve and a controlled flow chopper, creating a variable orifice to generate a harmonic anti-noise whose magnitude is related to the flow valve opening and whose phase is related to the angular position of the flow chopper. Such original HAPS device is driven with a dedicated complex envelope controller, since the chopper is controlled by a phase-locked loop. An experimental set-up is used to evaluate the precision of the HAPS in a plane wave active cancellation scheme with in-duct or external error microphones and a loudspeaker generating a primary sound pressure level up to 155 dB in the duct. The experimental results show that the HAPS is sufficiently stable and accurate to achieve single-frequency sound pressure level attenuations over 20 dB from 500 Hz to 800 Hz. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Active noise control of a duct using robust control theory
    Carmona, JC
    Alvarado, VM
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2000, 8 (06) : 930 - 938
  • [32] GLOBAL ACTIVE NOISE-CONTROL OF A ONE-DIMENSIONAL ACOUSTIC DUCT USING A FEEDBACK CONTROLLER
    HULL, AJ
    RADCLIFFE, CJ
    SOUTHWARD, SC
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1993, 115 (03): : 488 - 494
  • [33] ACTIVE NOISE-CONTROL IN A FINITE LENGTH DUCT
    GALLAND, MA
    SUNYACH, M
    ACUSTICA, 1987, 64 (04): : 210 - 216
  • [34] A Duct based Experimental Setup for Active Noise Control
    Zia, M. Kamil
    Ahmed, Ammar
    Tufail, M.
    PROCEEDINGS OF 2014 12TH INTERNATIONAL CONFERENCE ON FRONTIERS OF INFORMATION TECHNOLOGY, 2014, : 139 - 143
  • [35] Active acoustic noise control in motorcycle helmets
    Castane, Rosa
    Sanchez Pena, Ricardo S.
    REVISTA IBEROAMERICANA DE AUTOMATICA E INFORMATICA INDUSTRIAL, 2007, 4 (03): : 73 - +
  • [36] ACTIVE NOISE CONTROL OF A COOLING FAN IN A SHORT DUCT
    Kinney, Charles E.
    Villalta, Alberto
    de Callafon, Raymond A.
    PROCEEDINGS OF NOISECON/ASME NCAD-2008, 2009, : 249 - 259
  • [37] Active control of nonlinear noise processes in a linear duct
    Strauch, P
    Mulgrew, B
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1998, 46 (09) : 2404 - 2412
  • [38] Active structural acoustic control of impact noise
    Pinte, G.
    Boonen, R.
    Desmet, W.
    Sas, P.
    Proceedings of ISMA 2004: International Conference on Noise and Vibration Engineering, Vols 1-8, 2005, : 55 - 73
  • [39] Combined active noise and vibration control for a ventilation duct
    Rohlfing, J.
    Gardonio, P.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2012) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2012), 2012, : 519 - 531
  • [40] Active intensity control for the reduction of radiated duct noise
    Kang, SW
    Kim, YH
    JOURNAL OF SOUND AND VIBRATION, 1997, 201 (05) : 595 - 611