Acoustic comfort in office buildings with double skin glass facades

被引:5
|
作者
Huckemann, Volker [1 ]
Leao, Erika Borges [1 ]
Leao, Marlon [1 ]
机构
[1] Tech Univ Brunswick, Sch Architecture, Inst Gebaude & Solartech, Braunschweig, Germany
关键词
D O I
10.1002/bapi.200910040
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the Project TwinSkin at the IGS Institut fur Gebaude- und Solartechnik (Institute for Building Services and Energy Design) Brunswick/Germany, nine office buildings with double skin glass facades (DSF) were i.a. acoustically evaluated. Double skin facades (DSF), in comparison with other kind of facades, are frequently promoted to provide higher sound insulation from external noise, especially road traffic noise. DSF offer the advantage of operable windows or doors to the cavity, which provide occupant comfort; however, than questions about the impairment of acoustic comfort arise. The objective was to thoroughly analyse the apparent sound insulation properties of DSF in the extended frequency range from 50 to 5000 Hz. Measurements were performed according to the standard EN ISO 140-5 for different operation conditions of the openings and single number quantities were calculated. Additionally their respective spectrum adaptation terms (C and C(tr)) were considered. A remarkable influence of DSF design on the sound insulation properties was found. The results show high levels of weighted apparent sound reduction up to 60 dB, but also there were results from only 35 dB to 40 dB. Multi storey fagades tend to better sound insulation performance in relation to the other types of DSF, an average of 13 dB higher values were found. Esthetical favourable arrangements of DSF can provide substantial negative influence on sound insulation.
引用
收藏
页码:305 / 312
页数:8
相关论文
共 50 条
  • [31] Application of double glazed facades with horizontal and vertical louvers to increase natural air flow in office buildings
    Pourshab, Nasrin
    Tehrani, Mehdi Dadkhah
    Toghraie, Davood
    Rostami, Sara
    [J]. ENERGY, 2020, 200 (200)
  • [32] Energy efficiency of double-skin facade in office buildings of Shanghai
    Sun, Lu
    Jones, Phil J.
    Alexander, Don K.
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1755 - 1762
  • [33] Biomimetic-Computational Design for Double Facades in Hot Climates A Porous Folded Facade for Office Buildings
    El Ahmar, Salma
    Fioravanti, Antonio
    [J]. ECAADE 2015: REAL TIME - EXTENDING THE REACH OF COMPUTATION, VOL 2, 2015, : 687 - 696
  • [34] Daylighting characterstics of existing double-skin facade office buildings
    Shameri, M. A.
    Alghoul, M. A.
    Elayeb, OmKalthum
    Zain, M. Fauzi M.
    Alrubaih, M. S.
    Amir, Halizawati
    Sopian, K.
    [J]. ENERGY AND BUILDINGS, 2013, 59 : 279 - 286
  • [35] Summer thermal comparative experimental study of double plant-skin facades and double skin facades
    Bao, Shenglin
    Zou, Simin
    Li, Baofeng
    Chen, Qiuyu
    Zhao, Mingqiao
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 72
  • [36] Integration of double facades and ventilation systems in buildings
    Di Maio, F
    van Paassen, AHC
    [J]. ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 1225 - 1232
  • [37] Effect of Thermal, Acoustic and Air Quality Perception Interactions on the Comfort and Satisfaction of People in Office Buildings
    Bourikas, Leonidas
    Gauthier, Stephanie
    En, Nicholas Khor Song
    Xiong, Peiyao
    [J]. ENERGIES, 2021, 14 (02)
  • [38] Energy Performance and Thermal Comfort of Double-Skin and Single-Skin Facades in Warm-Climate Offices
    Alibaba, Halil Z.
    Ozdeniz, Mesut B.
    [J]. JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2016, 15 (03) : 635 - 642
  • [39] Adaptive thermal comfort for resilient office buildings
    Trebilcock-Kelly, Maureen
    Soto-Munoz, Jaime
    Marin-Restrepo, Laura
    [J]. CLIMATE RESILIENT CITIES - ENERGY EFFICIENCY & RENEWABLES IN THE DIGITAL ERA (CISBAT 2019), 2019, 1343
  • [40] Double Skin Facades as Mass Dampers
    Fu, Tat S.
    [J]. 2013 AMERICAN CONTROL CONFERENCE (ACC), 2013, : 4742 - 4746