Luminescence lifetime-based sensor for cyanide and related anions

被引:438
|
作者
Anzenbacher, P [1 ]
Tyson, DS
Jursíková, K
Castellano, FN
机构
[1] Bowling Green State Univ, Dept Chem, Bowling Green, OH 43403 USA
[2] Bowling Green State Univ, Ctr Photochem Sci, Bowling Green, OH 43403 USA
关键词
D O I
10.1021/ja0259180
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new Ru(II) complex is described which serves as a luminescence lifetime-based sensor for fluoride and cyanide anions (KF = 640 000 mol-1, KCN = 430 000 mol-1). This chromophore displays observable changes in its UV-vis and steady-state luminescence spectra upon cyanide binding. Prior to cyanide addition, this complex exhibits a single-exponential lifetime (τ = 377 ± 20 ns). With increasing cyanide concentrations, the intensity decays are composed of two exponentials: long τ (320-370 ns) and short τ (13-17 ns). The average lifetimes shorten as a function of cyanide concentration since the fractional intensity shifts from an initial dominant long lifetime component to the short lifetime component. This work represents the first example of a direct method for the luminescence lifetime-based sensing of anions. Copyright © 2002 American Chemical Society.
引用
收藏
页码:6232 / 6233
页数:2
相关论文
共 50 条
  • [21] Lifetime-based pH sensor system based on a polymer supported ruthenium(II) complex
    Clarke, Y
    Xu, WY
    Demas, JN
    DeGraff, BA
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (15) : 3468 - 3475
  • [22] Luminescence Lifetime-Based In Vivo Detection with Responsive Rare Earth-Dye Nanocomposite
    Kong, Mengya
    Gu, Yuyang
    Liu, Yulai
    Shi, Yibing
    Wu, Na
    Feng, Wei
    Li, Fuyou
    [J]. SMALL, 2019, 15 (46)
  • [23] Fluorescence lifetime-based determination of anions using a site-directed mutant enzyme transducer
    Thompson, RB
    Lin, HJ
    Ge, ZF
    Johnson, K
    Fierke, CA
    [J]. ADVANCES IN FLUORESCENCE SENSING TECHNOLOGY III, 1997, 2980 : 247 - 257
  • [24] FLUORESCENCE LIFETIME-BASED SENSING AND IMAGING
    SZMACINSKI, H
    LAKOWICZ, JR
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) : 16 - 24
  • [25] Fluorescence lifetime-based sensing of methanol
    Chang, Q
    Lakowicz, JR
    Rao, G
    [J]. ANALYST, 1997, 122 (02) : 173 - 177
  • [26] FIBEROPTIC LIFETIME-BASED ENZYME BIOSENSOR
    PAPKOVSKY, DB
    OLAH, J
    KUROCHKIN, IN
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) : 525 - 530
  • [27] Lifetime-based sensing: Influence of the microenvironment
    Draxler, S
    Lippitsch, ME
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (05) : 753 - 757
  • [28] Lifetime-based TCP service differentiation
    Nikolaidis, I
    Wu, X
    [J]. COMPUTER COMMUNICATIONS, 2005, 28 (01) : 108 - 124
  • [29] Precision and Accuracy of Luminescence Lifetime-Based Phosphor Thermometry: A Case Study of Eu(III):YSZ
    Heeg, B.
    Jenkins, T. P.
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 885 - 890
  • [30] In situ monitoring of dissolved carbon dioxide using a fluorescence lifetime-based sensor.
    Harms, P
    Randers-Eichhorn, L
    Rao, G
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U248 - U248