A Novel Device to Evaluate the Vibrotactile Threshold

被引:1
|
作者
Gandhi, Minu Shikha [1 ]
Redd, Christian B. [1 ]
Tuckett, Robert P. [2 ]
Sesek, Richard F. [3 ]
Bamberg, Stacy J. M. [1 ]
机构
[1] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Physiol, Salt Lake City, UT 84112 USA
[3] Auburn Univ, Dept Ind & Syst Engn, Auburn, AL 36849 USA
关键词
vibrotactile; threshold; medical instrumentation; perception; neuropathy; carpal tunnel syndrome; CARPAL-TUNNEL-SYNDROME; COMPRESSION; NEUROPATHY; VIBROMETRY;
D O I
10.1115/1.4006901
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents the initial prototype design of a vibrotactile threshold evaluator for the workplace (VTEW), which is portable and configurable in terms of the probe diameter (2-10 mm), applied frequency (1-500 Hz), angle of probe (0-120 deg), and displacement of probe (1-1500 mu m), and is operated with a customizable LABVIEW interface. The vibrotactile threshold is the minimum amplitude of vibration that is perceived at a particular frequency by a subject and is analogous to a hearing test. It can be used to evaluate neuropathy, for instance due to carpal tunnel syndrome or peripheral neuropathy secondary to diabetes. The vibrotactile threshold (VT) at 50 Hz was evaluated using VTEW and an established device, the Vibrotactile Tester (VTT). These results were compared for validation of VTEW. Each subject underwent Phalen's and Tinel's test, and the results of these clinical evaluations for carpal tunnel syndrome were used to classify subjects as symptomatic and asymptomatic. The results of the VTEW and the VTT were statistically similar and the age correction developed for both devices from this study were similar to the previously conducted studies. The mean VT values from the VTEW showed an increased VT for symptomatic subjects. The low frequency range of the VTEW was used to evaluate the VT at 4 Hz, and a comparison of VT at 4 Hz and 50 Hz showed a higher sensitivity of subjects to 50 Hz as compared to 4 Hz. The gender effect on VT was also studied and discussed, along with recommendation for further investigation. A novel and highly customizable device for testing the vibrotactile threshold is presented, with results demonstrating identification of symptomatic subjects. This device could be used to regularly test workers at risk for developing carpal tunnel syndrome (e. g. assembly line workers) to monitor for elevations in VT. Other applications include using the low frequency to evaluate peripheral neuropathy. [DOI: 10.1115/1.4006901]
引用
收藏
页数:9
相关论文
共 50 条
  • [21] COMPARISON OF VIBROTACTILE THRESHOLD AND SUPRATHRESHOLD RESPONSES IN MEN AND WOMEN
    VERRILLO, RT
    PERCEPTION & PSYCHOPHYSICS, 1979, 26 (01): : 20 - 24
  • [22] A Novel Wireless Vibrotactile Display Device for Representing 3DOF Force Feedback in Teleoperation
    Won, J. H.
    Yang, G. H.
    Jeon, J. W.
    2015 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2015, : 1749 - 1753
  • [23] VIBROTACTILE STIMULATION - INVESTIGATION OF PSYCHOPHYSICAL METHODS FOR ESTABLISHING THRESHOLD
    HALL, DE
    ARNST, DJ
    FUCCI, DJ
    PERCEPTUAL AND MOTOR SKILLS, 1972, 34 (03) : 891 - &
  • [24] Effect of menstruation on vibrotactile threshold in the peripheral median nerve
    Espritt, AJ
    Kerk, CJ
    Congleton, JJ
    Crumpton, LL
    White, KM
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 1997, 19 (03) : 201 - 204
  • [25] Perceptual analysis of vibrotactile flows on a mobile device
    Choi, S. (choism@postech.ac.kr), 1600, Institute of Electrical and Electronics Engineers Inc., United States (06):
  • [26] Perceptual Analysis of Vibrotactile Flows on a Mobile Device
    Seo, Jongman
    Choi, Seungmoon
    IEEE TRANSACTIONS ON HAPTICS, 2013, 6 (04) : 522 - 527
  • [27] Frequency Modulation Based Vibrotactile Device for Teleoperation
    Pham, H. Phong
    Chellali, Ryad
    SMC-IT 2009: THIRD IEEE INTERNATIONAL CONFERENCE ON SPACE MISSION CHALLENGES FOR INFORMATION TECHNOLOGY, PROCEEDINGS, 2009, : 98 - 105
  • [28] VIBROTACTILE TEMPORAL SUMMATION FOR THRESHOLD AND SUPRATHRESHOLD LEVELS OF STIMULATION
    GESCHEIDER, GA
    JOELSON, JM
    PERCEPTION & PSYCHOPHYSICS, 1983, 33 (02): : 156 - 162
  • [29] Effect of menstruation on vibrotactile threshold in the peripheral median nerve
    Safety Engineering Program, Texas A and M University, College Station, TX 77843-3133, United States
    不详
    不详
    INT. J. IND. ERGON., 3 (201-204):
  • [30] ARENA:a novel device to evaluate spatial and imagery skills through sounds
    Setti, Walter
    Cuturi, Luigi F.
    Maviglia, Antonio
    Sandini, Giulio
    Gori, Monica
    2019 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2019,