A Novel Device to Evaluate the Vibrotactile Threshold

被引:1
|
作者
Gandhi, Minu Shikha [1 ]
Redd, Christian B. [1 ]
Tuckett, Robert P. [2 ]
Sesek, Richard F. [3 ]
Bamberg, Stacy J. M. [1 ]
机构
[1] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Physiol, Salt Lake City, UT 84112 USA
[3] Auburn Univ, Dept Ind & Syst Engn, Auburn, AL 36849 USA
关键词
vibrotactile; threshold; medical instrumentation; perception; neuropathy; carpal tunnel syndrome; CARPAL-TUNNEL-SYNDROME; COMPRESSION; NEUROPATHY; VIBROMETRY;
D O I
10.1115/1.4006901
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents the initial prototype design of a vibrotactile threshold evaluator for the workplace (VTEW), which is portable and configurable in terms of the probe diameter (2-10 mm), applied frequency (1-500 Hz), angle of probe (0-120 deg), and displacement of probe (1-1500 mu m), and is operated with a customizable LABVIEW interface. The vibrotactile threshold is the minimum amplitude of vibration that is perceived at a particular frequency by a subject and is analogous to a hearing test. It can be used to evaluate neuropathy, for instance due to carpal tunnel syndrome or peripheral neuropathy secondary to diabetes. The vibrotactile threshold (VT) at 50 Hz was evaluated using VTEW and an established device, the Vibrotactile Tester (VTT). These results were compared for validation of VTEW. Each subject underwent Phalen's and Tinel's test, and the results of these clinical evaluations for carpal tunnel syndrome were used to classify subjects as symptomatic and asymptomatic. The results of the VTEW and the VTT were statistically similar and the age correction developed for both devices from this study were similar to the previously conducted studies. The mean VT values from the VTEW showed an increased VT for symptomatic subjects. The low frequency range of the VTEW was used to evaluate the VT at 4 Hz, and a comparison of VT at 4 Hz and 50 Hz showed a higher sensitivity of subjects to 50 Hz as compared to 4 Hz. The gender effect on VT was also studied and discussed, along with recommendation for further investigation. A novel and highly customizable device for testing the vibrotactile threshold is presented, with results demonstrating identification of symptomatic subjects. This device could be used to regularly test workers at risk for developing carpal tunnel syndrome (e. g. assembly line workers) to monitor for elevations in VT. Other applications include using the low frequency to evaluate peripheral neuropathy. [DOI: 10.1115/1.4006901]
引用
收藏
页数:9
相关论文
共 50 条
  • [1] VisPad: A novel device for vibrotactile force feedback
    Weissgerber, D
    Bridgeman, B
    Pang, A
    12TH INTERNATIONAL SYMPOSIUM ON HAPTIC INTERFACES FOR VIRTUAL ENVIRONMENT AND TELEOPERATOR SYSTEMS, PROCEEDINGS, 2004, : 50 - 57
  • [2] VIBROTACTILE POSTSTIMULATORY THRESHOLD SHIFT
    VERRILLO, RT
    SCHMIEDT, RA
    BULLETIN OF THE PSYCHONOMIC SOCIETY, 1974, 4 (NA5) : 484 - 486
  • [3] A Novel Head-Mounted Navigation Device Based on Vibrotactile Stimulation
    Ma, Shimeng
    Liu, Peter Xiaoping
    Gao, Jinfeng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 7
  • [4] A novel device for delivering two-site vibrotactile stimuli to the skin
    Tannan, V
    Dennis, R
    Tommerdahl, M
    JOURNAL OF NEUROSCIENCE METHODS, 2005, 147 (02) : 75 - 81
  • [5] A Novel Vibrotactile Biofeedback Device for Optimizing Neuromuscular Control in Piano Playing
    Oku, Takanori
    Furuya, Shinichi
    2019 26TH IEEE CONFERENCE ON VIRTUAL REALITY AND 3D USER INTERFACES (VR), 2019, : 1554 - 1555
  • [6] EFFECT OF CONTACTOR AREA ON VIBROTACTILE THRESHOLD
    VERRILLO, RT
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1963, 35 (12): : 1962 - &
  • [7] The effects of static indentation on vibrotactile threshold
    Makous, JC
    Gescheider, GA
    Bolanowski, SJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 99 (05): : 3149 - 3153
  • [8] Vibrotactile threshold is elevated in temporomandibular disorders
    Hollins, M
    Sigurdsson, A
    Fillingim, L
    Goble, AK
    PAIN, 1996, 67 (01) : 89 - 96
  • [9] Effects of static indentation on vibrotactile threshold
    Makous, James C.
    Gescheider, George A.
    Bolanowski, Stanley J.
    1996, (99):
  • [10] EFFECT OF SPATIAL PARAMETERS ON VIBROTACTILE THRESHOLD
    VERRILLO, RT
    JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1966, 71 (04): : 570 - &