Characteristics of Collagen Changes in Small Intestine Anastomoses Induced by High-Frequency Electric Field Welding

被引:4
|
作者
Zhu, Caihui [1 ]
Yin, Li [1 ]
Xu, Jianzhi [1 ]
Yang, Xingjian [2 ]
Wang, Hao [2 ]
Xiang, Xiaowei [2 ]
Liu, Haotian [2 ]
Liu, Kefu [1 ]
机构
[1] Fudan Univ, Sch Informat Sci & Technol, Shanghai 200433, Peoples R China
[2] Fudan Univ, Acad Engn & Technol, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
small intestine; tissue welding; Raman spectroscopy; orientation analysis; SMALL-BOWEL; CLOSURE; MECHANISMS; DEVICE; FUSION; TISSUE; VIVO; SEAL;
D O I
10.3390/biom12111683
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
High-frequency electric field welding-induced tissue fusion has been explored as an advanced surgical method for intestinal anastomoses; however, intrinsic mechanisms remain unclear. The aim of this study was to investigate microcosmic changes of collagen within the fusion area, with various parameters. Ex vivo small intestine was fused with mucosa-mucosa. Four levels of compressive pressure (100 kPa, 150 kPa, 200 kPa, 250 kPa) were applied for 10 s in order to fuse the colons under a power level of 140 W. Then, collagen fibers of the fusion area were examined by fibrillar collagen alignment and TEM. Three levels of power (90 W, 110 W, 140 W) and three levels of time (5 s, 10 s, 20 s) were applied in order to fuse colons at 250 kPa, and then collagen within the fusion area was examined by Raman spectroscopy. Fibrillar collagen alignment analysis showed that with the increase in compression pressure, alignment of the collagen in the fusion area gradually increased, and the arrangement of collagen fibers tended to be consistent, which was conducive to the adhesion of collagen fibers. TEM showed that pressure changed the distribution and morphology of collagen fibers. Raman spectroscopy showed that increased power and time within a certain range contributed to collagen cross linking. Peak positions of amide I band and amide III band changed. These results suggested that higher power and a longer amount of time resulted in a decrease in non-reducible cross links and an increase in reducible cross links. Compression pressure, power, and time can affect the state of collagen, but the mechanisms are different. Compressive pressure affected the state of collagen by changing its orientation; power and time denatured collagen by increasing temperature and improved the reducible cross linking of collagen to promote tissue fusion.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] The heating of thin molybdenum films in a high-frequency electric field
    Wright, DA
    PROCEEDINGS OF THE PHYSICAL SOCIETY, 1940, 52 : 253 - 265
  • [42] THE NATURE OF THE EFFECT OF A HIGH-FREQUENCY ELECTRIC FIELD UPON PARAMECIUM
    Kahler, H.
    Chalkley, H. W.
    Voegtlin, Carl
    PUBLIC HEALTH REPORTS, 1929, 44 (07) : 339 - 347
  • [43] Instability of a liquid jet in a high-frequency alternating electric field
    E. A. Demekhin
    S. V. Polyanskikh
    Journal of Applied Mechanics and Technical Physics, 2009, 50 : 776 - 784
  • [44] High-frequency electric field trapping of individual human spermatozoa
    Fuhr, G
    Müller, T
    Baukloh, V
    Lucas, K
    HUMAN REPRODUCTION, 1998, 13 (01) : 136 - 141
  • [45] Estimation of weld quality in high-frequency electric resistance welding with image processing
    Kim, D.
    Kim, T.
    Park, Y. W.
    Sung, K.
    Kang, M.
    Kim, C.
    Lee, C.
    Rhee, S.
    WELDING JOURNAL, 2007, 86 (03) : 71S - 79S
  • [46] INTERACTIONS BETWEEN ION WAVES AND A HIGH-FREQUENCY ELECTRIC FIELD
    TAKAMURA, S
    AIHARA, S
    TAKAYAMA, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1971, 31 (03) : 925 - &
  • [47] GENERATION OF CELL PROCESSES IN A HIGH-FREQUENCY ELECTRIC-FIELD
    MARGOLIS, LB
    POPOV, SV
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1988, 20 (1-3): : 143 - 153
  • [48] Plasma in a High-Frequency Electric Field with a Reflective Condition on the Boundary
    Latyshev, A. V.
    Yushkanov, A. A.
    FLUID DYNAMICS, 2006, 41 (01) : 161 - 172
  • [49] HIGH-FREQUENCY ULTRASOUND AMPLIFICATION IN A STRONG ELECTRIC-FIELD
    ZILBERMAN, PE
    MISHIN, AG
    RADIOTEKHNIKA I ELEKTRONIKA, 1972, 17 (11): : 2384 - +
  • [50] AMPLIFICATION OF HIGH-FREQUENCY ULTRASOUND IN A STRONG ELECTRIC FIELD.
    Zil'berman, P.Ye.
    Mishin, A.G.
    1911, (17):