Determining Healthiness of Shunt Reactor through Signature Analysis - A Case Study

被引:0
|
作者
Paul, Devaprasad [1 ]
Goswami, Arup Kumar [1 ]
机构
[1] Natl Inst Technol Silchar, Elect Engn Dept, Silchar, Assam, India
关键词
Frequency response analysis; winding deformation;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Sweep frequency response analysis (SFRA) is an analytical means of comparing signatures during the normal and faulty condition to confirm the healthiness of a transformer or reactor. It is one of the most prominent tools for confirming the deformities in core, winding and the lower tapering portion of the bushing and also helps us to detect the fault due to both electrical and mechanical cause. In other words the complete healthiness of the transformer or reactor inside the oil tank can be visualized with the help of this testing. Though many case studies have been undertaken to emphasize the helpfulness of SFRA in the transformer, a few of them have demonstrated its usefulness in ascertaining the healthiness of the shunt reactor. In this paper a case study has been demonstrated to depict the usefulness of SFRA in detecting the mechanical and electrical healthiness of a shunt reactor after a severe fault. This paper will help the utilities to accentuate more in the utilization of this test to access the healthiness of a shunt reactor and in turn increase its lifespan and reliability.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Naturalness and healthiness in ?ultra-processed foods?: A multidisciplinary perspective and case study
    Sanchez-Siles, Luisma
    Roman, Sergio
    Fogliano, Vincenzo
    Siegrist, Michael
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2022, 129 : 667 - 673
  • [32] Analysis of the Influence of the 6-Pulse Thyristor-Bridge Input Reactor Size on the Shunt Active Power Filter Work Efficiency: A Case Study
    Mboving, Chamberlin Stephane Azebaze
    Hanzelka, Zbigniew
    ENERGIES, 2024, 17 (01)
  • [33] Management of access through biometric control: A case study based on automatic signature verification
    M.C. Fairhust
    S. Ng
    Universal Access in the Information Society, 2001, 1 (1) : 31 - 39
  • [34] Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor
    Chen, Jing
    Chen, Xiaoyue
    Feng, Siying
    Liu, Xinmeng
    Liu, Qin
    ENERGIES, 2025, 18 (05)
  • [35] Analysis of Vibration Signals of HUV Shunt Reactor Based on CRP and RQA
    Chen, Xuan
    Pan, Xincheng
    Liu, Zhenyao
    Ma, Hongzhong
    2019 IEEE MILAN POWERTECH, 2019,
  • [36] ANALYSIS OF MAGNETIC-FIELDS OF A DELTA-TYPE SHUNT REACTOR
    ISHIHARA, Y
    MORINO, T
    TODAKA, T
    IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (04) : 2846 - 2848
  • [37] EQUIVALENT-CIRCUIT AND ANALYSIS OF 3-PHASE SHUNT REACTOR
    AMANO, H
    OKUNO, K
    ELECTRICAL ENGINEERING IN JAPAN, 1977, 97 (04) : 61 - 67
  • [38] The study of high voltage shunt reactor protection of series compensated line
    Hu, YF
    Yin, XG
    Chen, DS
    Zhang, Z
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 262 - 268
  • [39] NEW METHOD FOR DETERMINING SUBCRITICALITY OF DIORIT REACTOR USING REACTOR NOISE-ANALYSIS
    BEHRINGER, K
    JESCHKI, W
    LEONI, B
    PHILDIUS, J
    PRUYS, HS
    SEIFRITZ, W
    HELVETICA PHYSICA ACTA, 1974, 47 (04): : 452 - 453
  • [40] CASE STUDY OF A REACTOR FIRE
    ZIELINSK.RM
    CHEMICAL ENGINEERING PROGRESS, 1967, 63 (08) : 50 - &