Simultaneous Multislice Accelerated Free-Breathing Diffusion-Weighted Imaging of the Liver at 3T

被引:62
|
作者
Obele, Chika C. [1 ]
Glielmi, Christopher [2 ]
Ream, Justin [1 ]
Doshi, Ankur [1 ]
Campbell, Naomi [1 ,3 ]
Zhang, Hoi Cheung [1 ]
Babb, James [1 ]
Bhat, Himanshu [4 ]
Chandarana, Hersh [1 ]
机构
[1] NYU, Langone Med Ctr, Dept Radiol, New York, NY 10016 USA
[2] Siemens HealthCare, New York, NY USA
[3] Dept Radiol, New York, NY USA
[4] Siemens HealthCare, Charlestown, MA USA
来源
ABDOMINAL IMAGING | 2015年 / 40卷 / 07期
关键词
Liver MRI; Diffusion-weighted imaging; Simultaneous multislice acceleration DWI; Multiband DWI; ADC MEASUREMENTS; FAST MRI; BREATHHOLD; REPRODUCIBILITY; ACQUISITIONS; SENSITIVITY; METASTASES; DISEASE; LESIONS; HOLD;
D O I
10.1007/s00261-015-0447-3
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Purpose: To perform image quality comparison between accelerated multiband diffusion acquisition (mb2-DWI) and conventional diffusion acquisition (c-DWI) in patients undergoing clinically indicated liver MRI. Methods: In this prospective study 22 consecutive patients undergoing clinically indicated liver MRI on a 3-T scanner equipped to perform multiband diffusion-weighed imaging (mb-DWI) were included. DWI was performed with single-shot spin-echo echo-planar technique with fat-suppression in free breathing with matching parameters when possible using c-DWI, mb-DWI, and multiband DWI with a twofold acceleration (mb2-DWI). These diffusion sequences were compared with respect to various parameters of image quality, lesion detectability, and liver ADC measurements. Results: Accelerated mb2-DWI was 40.9% faster than c-DWI (88 vs. 149 s). Various image quality parameter scores were similar or higher on mb2-DWI when compared to c-DWI. The overall image quality score (averaged over the three readers) was significantly higher for mb-2 compared to c-DWI for b = 0 s/mm(2) (3.48 +/- A 0.52 vs. 3.21 +/- A 0.54; p = 0.001) and for b = 800 s/mm(2) (3.24 +/- A 0.76 vs. 3.06 +/- A 0.86; p = 0.010). Total of 25 hepatic lesions were visible on mb2-DWI and c-DWI, with identical lesion detectability. There was no significant difference in liver ADC between mb2-DWI and c-DWI (p = 0.12). Bland-Altman plot demonstrates lower mean liver ADC with mb2-DWI compared to c-DWI (by 0.043 x 10(-3) mm(2)/s or 3.7% of the average ADC). Conclusion: Multiband technique can be used to increase acquisition speed nearly twofold for free-breathing DWI of the liver with similar or improved overall image quality and similar lesion detectability compared to conventional DWI.
引用
收藏
页码:2323 / 2330
页数:8
相关论文
共 50 条
  • [21] Diffusion Tractography of the Entire Left Ventricle by Using Free-breathing Accelerated Simultaneous Multisection Imaging
    Mekkaoui, Choukri
    Reese, Timothy G.
    Jackowski, Marcel P.
    Cauley, Stephen F.
    Setsompop, Kawin
    Bhat, Himanshu
    Sosnovik, David E.
    RADIOLOGY, 2017, 282 (03) : 850 - 856
  • [22] Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging
    Nakamura, Yuko
    Higaki, Toru
    Akiyama, Yuji
    Fukumoto, Wataru
    Kajiwara, Kenji
    Kaichi, Yoko
    Honda, Yukiko
    Komoto, Daisuke
    Tatsugami, Fuminari
    Iida, Makoto
    Ohmoto, Toshifumi
    Date, Shuji
    Awai, Kazuo
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2016, 3 : 138 - 144
  • [23] Image Quality and Detection of Small Focal Liver Lesions in Diffusion-Weighted Imaging Comparison of Navigator Tracking and Free-Breathing Acquisition
    Saake, Marc
    Seuss, Hannes
    Riexinger, Andreas
    Bickelhaupt, Sebastian
    Hammon, Matthias
    Uder, Michael
    Laun, Frederik B.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (09) : 579 - 590
  • [24] Diagnosis of focal liver lesions suspected of metastases by diffusion-weighted imaging (DWI): systematic comparison favors free-breathing technique
    Baltzer, Pascal A. T.
    Schelhorn, Juliane
    Benndorf, Matthias
    Dietzel, Matthias
    Kaiser, Werner A.
    CLINICAL IMAGING, 2013, 37 (01) : 97 - 103
  • [25] Qualitative Effect of Gadolinium on Diffusion-Weighted MR Imaging of the Liver, Spleen, Pancreas and Kidney at 3T
    Wang, C.
    Dale, B.
    Neville, A.
    Boll, D.
    Samei, E.
    Merkle, E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [26] Prostate diffusion-weighted imaging at 3T: effect of intravenous gadobutrol administration
    Chan Kyo Kim
    Jung Jae Park
    Byung Kwan Park
    European Radiology, 2016, 26 : 1450 - 1456
  • [27] Prostate diffusion-weighted imaging at 3T: effect of intravenous gadobutrol administration
    Kim, Chan Kyo
    Park, Jung Jae
    Park, Byung Kwan
    EUROPEAN RADIOLOGY, 2016, 26 (05) : 1450 - 1456
  • [28] Simultaneous Multislice Diffusion-Weighted Imaging of the Kidney A Systematic Analysis of Image Quality
    Kenkel, David
    Barth, Borna K.
    Piccirelli, Marco
    Filli, Lukas
    Finkenstadt, Tim
    Reiner, Cacilia S.
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2017, 52 (03) : 163 - 169
  • [29] Accelerated diffusion-weighted imaging for lymph node assessment in the pelvis applying simultaneous multislice acquisition: A healthy volunteer study
    Ciritsis, Alexander
    Rossi, Cristina
    Maroon, Magda
    Van, Valerie Doan Phi
    Boss, Andreas
    MEDICINE, 2018, 97 (32)
  • [30] Diffusion-weighted imaging of the liver: comparison of image quality between monopolar and bipolar acquisition schemes at 3T
    Andrew B. Rosenkrantz
    Christian Geppert
    Michael Kiritsy
    Thorsten Feiweier
    David J. Mossa
    Hersh Chandarana
    Abdominal Imaging, 2015, 40 : 289 - 298